Literature DB >> 19647309

The influence of various light curing units on the cytotoxicity of dental adhesives.

Bernd W Sigusch1, Torsten Pflaum, Andrea Völpel, Matthias Schinkel, Klaus D Jandt.   

Abstract

OBJECTIVES: The objective of this study was to test the hypothesis that various light curing units (LCUs) have an influence on the cytotoxic action of adhesive systems.
METHODS: Samples of the dental adhesives (Syntac), iBondTM, Clearfil Protect Bond, Prime & Bond NT, Adper Prompt L-Pop) were prepared in microwell plates, making use of the LCUs Voco Polofil Lux (VPL), EMS Swiss Master Light (SML) and the LED prototype developed by the IMT of Jena University. To obtain extracts, the samples were topped with cell culture medium, which was changed daily on the 1st to 7th days and then on the 14th, 21st and 28th day, and stored for further use at -20 degrees C. Human gingival fibroblasts (HGFs) were cultivated in the extract-containing medium for 48 h. The viability of the HGFs was determined by the neutral red (NR) uptake test. The statistical test was performed by one-way ANOVA according to Bonferroni.
RESULTS: During the first few days, reduction of the viability rates of the HGFs by 85-90% were observed in all adhesives. A rise up to a plateau phase was observed at different times depending on the materials. The influence of the LCUs on the cytotoxic action of the dental adhesives was clearly evident for the adhesives Syntac and Clearfil Protect Bond. In case of the Syntac extracts, cytotoxicity after polymerization with the VPL was statistically significant reduced compared to the other LCUs used (p<0.001). A comparison between all the adhesives used proved that Adper Prompt L-Pop and Prime & Bond NT had the lowest overall cytotoxicities. SIGNIFICANCE: In practice, one should use combinations of dental adhesive and LCU in which the material has the least toxic influences.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19647309     DOI: 10.1016/j.dental.2009.06.016

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  9 in total

1.  Immortalized gingival fibroblasts as a cytotoxicity test model for dental materials.

Authors:  Rasika P Illeperuma; Young J Park; Jin M Kim; Jung Y Bae; Zhong M Che; Hwa K Son; Mi R Han; Kwang M Kim; Jin Kim
Journal:  J Mater Sci Mater Med       Date:  2011-11-10       Impact factor: 3.896

2.  Clinical long-term success of contemporary nano-filled resin composites in class I and II restorations cured by LED or halogen light.

Authors:  Torsten Pflaum; Stefan Kranz; Regina Montag; Arndt Güntsch; Andrea Völpel; Robin Mills; Klaus Jandt; Bernd Sigusch
Journal:  Clin Oral Investig       Date:  2017-10-28       Impact factor: 3.573

3.  Influence of light-curing distance on degree of conversion and cytotoxicity of etch-and-rinse and self-etch adhesives.

Authors:  Florian J Wegehaupt; Nancy Lunghi; Georgios N Belibasakis; Thomas Attin
Journal:  BMC Oral Health       Date:  2016-07-07       Impact factor: 2.757

4.  Cytotoxicity of Light-Cured Dental Materials according to Different Sample Preparation Methods.

Authors:  Myung-Jin Lee; Mi-Joo Kim; Jae-Sung Kwon; Sang-Bae Lee; Kwang-Mahn Kim
Journal:  Materials (Basel)       Date:  2017-03-14       Impact factor: 3.623

5.  Cytotoxicity Test of One-Step Self-Etching Bonding Agents by Standardized Dentin Barrier Test Using Polyurethane Discs.

Authors:  Mi-Joo Kim; Kyoung-Nam Kim; Kwang-Mahn Kim
Journal:  Materials (Basel)       Date:  2013-12-23       Impact factor: 3.623

6.  The effects of bluephase LED light on fibroblasts.

Authors:  Ana Ivanišević Malčić; Ivan Pavičić; Ivančica Trošić; Paris Simeon; Davor Katanec; Silvana Jukić Krmek
Journal:  Eur J Dent       Date:  2012-07

7.  Effect of emitted wavelength and light guide type on irradiance discrepancies in hand-held dental curing radiometers.

Authors:  Atsushi Kameyama; Akiko Haruyama; Masako Asami; Toshiyuki Takahashi
Journal:  ScientificWorldJournal       Date:  2013-10-10

8.  Influence of light-curing mode on the cytotoxicity of resin-based surface sealants.

Authors:  Florian J Wegehaupt; Tobias T Tauböck; Thomas Attin; Georgios N Belibasakis
Journal:  BMC Oral Health       Date:  2014-05-06       Impact factor: 2.757

9.  Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives: A Screening Study.

Authors:  Luisa Fröb; Stefan Rüttermann; Georgios E Romanos; Eva Herrmann; Susanne Gerhardt-Szép
Journal:  Materials (Basel)       Date:  2020-01-17       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.