Elisabeth A Koulaouzidou1, Maria Helvatjoglu-Antoniades, George Palaghias, Artemis Karanika-Kouma, Dimitrios Antoniades.
Abstract
OBJECTIVES: The purpose of this study was to evaluate the cytotoxic effect of six dental adhesives (Admira Bond, Clearfil Liner Bond 2V, ED Primer II, Fuji Bond LC, Gluma Comfort Bond, and NanoBond) applied to cell cultures.Entities:
Keywords: Cell culture; Cytotoxicity; Dental adhesives; In vitro; SRB-assay
Year: 2009 PMID: 19262725 PMCID: PMC2647953
Source DB: PubMed Journal: Eur J Dent
Composition and manufacturers of the dental adhesives tested.
| Material | Ingredients | Manufacturer |
|---|---|---|
| Admira bond (etch& rinse agent) | 2-hydroxyethyl methacrylate (HEMA) 11–14%
| VOCO GmbH
|
| Clearfil Liner Bond 2V (two component, one-step self-etch system) | Primer A: 10-Methacryloyloxydecyl dihydrogen phosphate (MDP)
| Kuraray Europe GmbH
|
| ED Primer II (Panavia F2.O) (two components, one-step self-etch system) | Liquid A: 2-hydroxyethyl methacrylate (HEMA)
| Kuraray Europe GmbH
|
| Fuji Bond LC (glass ionomer bonding agent) | Powder: Alumino-silicate glass 90–100%
| GC-Corporation
|
| Gluma Comfort Bond (one bottle total etch bonding agent) | 2-hydroxyethyl methacrylate (HEMA)
| Heraeus Kulzer
|
| NanoBond (two component, one-step self- etch system) | Self etching primer: Phosphoric acid, Xanthan gum, Water, AMPS
| Jeneric/Pentron Inc.
|
Figure 1Effect of the dental adhesives on RPC-C2A cells after 24 hours exposure. Bars show mean and standard deviation of sixplicates. Groups identified with the same letter are not significantly different (P>.05).
Figure 2Effect of the dental adhesives on MRC-5 cells after 24 hours exposure. Bars show mean and standard deviation of sixplicates. Groups identified with the same letter are not significantly different (P>.05).