Literature DB >> 24877822

Improved digital breast tomosynthesis images using automated ultrasound.

Xing Zhang1, Jie Yuan1, Sidan Du1, Oliver D Kripfgans2, Xueding Wang2, Paul L Carson2, Xiaojun Liu3.   

Abstract

PURPOSE: Digital breast tomosynthesis (DBT) offers poor image quality along the depth direction. This paper presents a new method that improves the image quality of DBT considerably through the a priori information from automated ultrasound (AUS) images.
METHODS: DBT and AUS images of a complex breast-mimicking phantom are acquired by a DBT/AUS dual-modality system. The AUS images are taken in the same geometry as the DBT images and the gradient information of the in-slice AUS images is adopted into the new loss functional during the DBT reconstruction process. The additional data allow for new iterative equations through solving the optimization problem utilizing the gradient descent method. Both visual comparison and quantitative analysis are employed to evaluate the improvement on DBT images. Normalized line profiles of lesions are obtained to compare the edges of the DBT and AUS-corrected DBT images. Additionally, image quality metrics such as signal difference to noise ratio (SDNR) and artifact spread function (ASF) are calculated to quantify the effectiveness of the proposed method.
RESULTS: In traditional DBT image reconstructions, serious artifacts can be found along the depth direction (Z direction), resulting in the blurring of lesion edges in the off-focus planes parallel to the detector. However, by applying the proposed method, the quality of the reconstructed DBT images is greatly improved. Visually, the AUS-corrected DBT images have much clearer borders in both in-focus and off-focus planes, fewer Z direction artifacts and reduced overlapping effect compared to the conventional DBT images. Quantitatively, the corrected DBT images have better ASF, indicating a great reduction in Z direction artifacts as well as better Z resolution. The sharper line profiles along the Y direction show enhancement on the edges. Besides, noise is also reduced, evidenced by the obviously improved SDNR values.
CONCLUSIONS: The proposed method provides great improvement on the quality of DBT images. This improvement makes it easier to locate and to distinguish a lesion, which may help improve the accuracy of the diagnosis using DBT imaging.

Mesh:

Year:  2014        PMID: 24877822      PMCID: PMC4032424          DOI: 10.1118/1.4875980

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

2.  Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization.

Authors:  Mitra Noroozian; Lubomir Hadjiiski; Sahand Rahnama-Moghadam; Katherine A Klein; Deborah O Jeffries; Renee W Pinsky; Heang-Ping Chan; Paul L Carson; Mark A Helvie; Marilyn A Roubidoux
Journal:  Radiology       Date:  2011-10-13       Impact factor: 11.105

3.  Convergence of the simultaneous algebraic reconstruction technique (SART).

Authors:  Ming Jiang; Ge Wang
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

4.  Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysis.

Authors:  Junqiang Lei; Pin Yang; Li Zhang; Yinzhong Wang; Kehu Yang
Journal:  Eur Radiol       Date:  2014-03       Impact factor: 5.315

5.  Digital breast tomosynthesis: observer performance study.

Authors:  David Gur; Gordon S Abrams; Denise M Chough; Marie A Ganott; Christiane M Hakim; Ronald L Perrin; Grace Y Rathfon; Jules H Sumkin; Margarita L Zuley; Andriy I Bandos
Journal:  AJR Am J Roentgenol       Date:  2009-08       Impact factor: 3.959

6.  A curve-filtered FDK (C-FDK) reconstruction algorithm for circular cone-beam CT.

Authors:  Liang Li; Yuxiang Xing; Zhiqiang Chen; Li Zhang; Kejun Kang
Journal:  J Xray Sci Technol       Date:  2011       Impact factor: 1.535

Review 7.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Spatial registration of temporally separated whole breast 3D ultrasound images.

Authors:  Ganesh Narayanasamy; Gerald L LeCarpentier; Marilyn Roubidoux; J Brian Fowlkes; Anne F Schott; Paul L Carson
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

9.  Breast cancer detection: radiologists' performance using mammography with and without automated whole-breast ultrasound.

Authors:  Kevin M Kelly; Judy Dean; Sung-Jae Lee; W Scott Comulada
Journal:  Eur Radiol       Date:  2010-07-15       Impact factor: 5.315

Review 10.  Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review.

Authors:  Monika Nothacker; Volker Duda; Markus Hahn; Mathias Warm; Friedrich Degenhardt; Helmut Madjar; Susanne Weinbrenner; Ute-Susann Albert
Journal:  BMC Cancer       Date:  2009-09-20       Impact factor: 4.430

View more
  1 in total

1.  Automated 3D ultrasound image segmentation to aid breast cancer image interpretation.

Authors:  Peng Gu; Won-Mean Lee; Marilyn A Roubidoux; Jie Yuan; Xueding Wang; Paul L Carson
Journal:  Ultrasonics       Date:  2015-10-31       Impact factor: 2.890