Application of the reference method isotope dilution gas chromatography mass spectrometry (ID/GC/MS) to establish metrological traceability for calibration and control of blood glucose test systems.

Elisabeth Andreis1, Kai Küllmer1, Matthias Appel2.   

Abstract

Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias.
© 2014 Diabetes Technology Society.

Entities:  

Keywords:  SMBG; accuracy; blood glucose monitoring; blood glucose monitoring systems; hexokinase; trueness

Mesh:

Substances:

Year:  2014        PMID: 24876614      PMCID: PMC4455442          DOI: 10.1177/1932296814523886

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  10 in total

1.  Implementation of reference systems in laboratory medicine.

Authors:  M M Müller
Journal:  Clin Chem       Date:  2000-12       Impact factor: 8.327

2.  NIST's role in measurement accuracy for diagnosis and monitoring of diabetes.

Authors:  Michael J Welch
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

3.  Performance evaluation of blood glucose monitoring devices.

Authors:  Ellen T Chen; James H Nichols; Show-Hong Duh; Glen Hortin
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

4.  Metrological traceability - a concept for standardization in laboratory medicine.

Authors:  Lothar Siekmann
Journal:  Clin Chem Lab Med       Date:  2013-05       Impact factor: 3.694

5.  Accuracy in clinical chemistry--does anybody care?

Authors:  N W Tietz
Journal:  Clin Chem       Date:  1994-06       Impact factor: 8.327

6.  Accurate and precise isotope dilution mass spectrometry method for determining glucose in whole blood.

Authors:  U Hannestad; A Lundblad
Journal:  Clin Chem       Date:  1997-05       Impact factor: 8.327

Review 7.  Metrological traceability in clinical biochemistry.

Authors:  Graham H White
Journal:  Ann Clin Biochem       Date:  2011-07-27       Impact factor: 2.057

8.  Glucose measurement: time for a gold standard.

Authors:  Joakim Hagvik
Journal:  J Diabetes Sci Technol       Date:  2007-03

9.  Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640.

Authors:  P J Twomey
Journal:  J Clin Pathol       Date:  2004-07       Impact factor: 3.411

10.  The accurate determination of serum glucose by isotope dilution mass spectrometry--two methods.

Authors:  E White; V M Welch; T Sun; L T Sniegoski; R Schaffer; H S Hertz; A Cohen
Journal:  Biomed Mass Spectrom       Date:  1982-09
  10 in total
  3 in total

Review 1.  Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.

Authors:  Guido Freckmann; Christina Schmid; Annette Baumstark; Malte Rutschmann; Cornelia Haug; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2015-04-14

2.  Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus.

Authors:  M J Fokkert; P R van Dijk; M A Edens; S Abbes; D de Jong; R J Slingerland; H J G Bilo
Journal:  BMJ Open Diabetes Res Care       Date:  2017-02-17

3.  Commutability of external quality assessment materials for point-of-care glucose testing using the Clinical and Laboratory Standards Institute and International Federation of Clinical Chemistry approaches.

Authors:  Yan Wang; Mario Plebani; Laura Sciacovelli; Shunli Zhang; Qingtao Wang; Rui Zhou
Journal:  J Clin Lab Anal       Date:  2020-04-27       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.