Effect of overnight wear of the Triggerfish(®) sensor on corneal thickness measured by Visante(®) anterior segment optical coherence tomography.

Ralitsa Hubanova1, Florent Aptel, Christophe Chiquet, Benjamin Mottet, Jean-Paul Romanet.   

Abstract

PURPOSE: To evaluate the effect of overnight wear of the Triggerfish(®) contact lens sensor (CLS) on central corneal thickness (CCT) using the Visante(®) anterior segment optical coherence tomography (AS-OCT).
METHODS: Twelve healthy subjects were studied in a sleep laboratory. An ophthalmic examination including ultrasonic CCT, corneal topography, specular microscopy and AS-OCT CCT was performed. Starting at 7 pm, the Triggerfish(®) CLS was fitted on one randomly selected eye. Similar AS-OCT measurements were taken on both eyes every 2 hr from 8 pm to 8 am. The CLS was removed just after the 8 am measurement session. Measurements were repeated at 9 am.
RESULTS: Twenty-four eyes of 12 subjects were studied (mean age, 22.1 ± 2.4 years; four men/eight women). CCT significantly increased during the night in both CLS and control eyes (p < 0.01). The maximal change was +4.4 ± 1.7% in the CLS eyes and +2.9 ± 1.8% in the control eyes (p < 0.05). Throughout the night, CCT significantly increased more in eyes with CLS than in control eyes (p < 0.05). There were significantly more corneal curvature irregularities after overnight wear of the CLS than in the control eye: +1.63 Dioptre (D) versus -0.02 D in the 3-mm central zone and +3.17 D versus +0.01 D in the 5-mm central zone (p < 0.01).
CONCLUSION: CCT and corneal curvature irregularities increased slightly but significantly more in eyes with the Triggerfish(®) CLS than in control eyes during overnight wear. Further studies are required to determine whether the corneal curvature changes modify the signal recorded by the sensor.
© 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  contact lens sensor; corneal thickness; intraocular pressure; optical coherence tomography

Mesh:

Year:  2013        PMID: 23848265     DOI: 10.1111/aos.12241

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  12 in total

1.  Improvement of fluctuations of intraocular pressure after cataract surgery in primary angle closure glaucoma patients.

Authors:  Naoki Tojo; Mitsuya Otsuka; Akio Miyakoshi; Kazuya Fujita; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-27       Impact factor: 3.117

2.  Can a contact lens sensor predict the success of trabectome surgery?

Authors:  Naoki Tojo; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-03       Impact factor: 3.117

3.  Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor.

Authors:  Atsuya Miki; Miho Kumoi; Naoyuki Maeda; Shizuka Koh; Kenji Matsushita; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2020-02-13       Impact factor: 2.447

4.  Association of Ambulatory Blood Pressure and Other Factors With Intraocular Pressure-Related 24-Hour Contact Lens Sensor Profile in Untreated Glaucoma.

Authors:  Kazuki Nakazawa; Tomomi Higashide; Shunsuke Tsuchiya; Satomi Shioya; Masahiko Okayama; Kazuhisa Sugiyama
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

5.  Efficacy of a contact lens sensor for monitoring 24-h intraocular pressure related patterns.

Authors:  Kaweh Mansouri; Robert N Weinreb; John H K Liu
Journal:  PLoS One       Date:  2015-05-05       Impact factor: 3.240

6.  Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor.

Authors:  John H K Liu; Kaweh Mansouri; Robert N Weinreb
Journal:  PLoS One       Date:  2015-06-15       Impact factor: 3.240

7.  The road ahead to continuous 24-hour intraocular pressure monitoring in glaucoma.

Authors:  Kaweh Mansouri
Journal:  J Ophthalmic Vis Res       Date:  2014-04

8.  Microfluidic Contact Lenses.

Authors:  Nan Jiang; Yunuen Montelongo; Haider Butt; Ali K Yetisen
Journal:  Small       Date:  2018-03-09       Impact factor: 13.281

Review 9.  Extraocular, periocular, and intraocular routes for sustained drug delivery for glaucoma.

Authors:  Uday B Kompella; Rachel R Hartman; Madhoosudan A Patil
Journal:  Prog Retin Eye Res       Date:  2020-09-04       Impact factor: 21.198

10.  Wearables in Medicine.

Authors:  Ali K Yetisen; Juan Leonardo Martinez-Hurtado; Barış Ünal; Ali Khademhosseini; Haider Butt
Journal:  Adv Mater       Date:  2018-06-11       Impact factor: 30.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.