Estimation of optimal pivot point for remote center of motion alignment in surgery.

Benoît Rosa1, Caspar Gruijthuijsen, Ben Van Cleynenbreugel, Jos Vander Sloten, Dominiek Reynaerts, Emmanuel Vander Poorten.   

Abstract

PURPOSE: The determination of an optimal pivot point ([Formula: see text]) is important for instrument manipulation in minimally invasive surgery. Such knowledge is of particular importance for robotic-assisted surgery where robots need to rotate precisely around a specific point in space in order to minimize trauma to the body wall while maintaining position control. Remote center of motion (RCM) mechanisms are commonly used, where the RCM point is manually and visually aligned. If not positioned appropriately, this misalignment might lead to intolerably high forces on the body wall with increased risk of postoperative complications or instrument damage. An automated method to align the RCM with the [Formula: see text] was developed and tested.
METHOD: Computer vision and a lightweight calibration procedure are used to estimate the optimal pivot point. One or two pre-calibrated cameras viewing the surgical scene are employed. The surgeon is asked to make short pivoting movements, applying as little torque as possible, with an instrument of choice passing through the insertion point while camera images are being recorded. The physical properties of an instrument rotating around a pivot point are exploited in a random sample consensus scheme to robustly estimate the ideal position of the RCM in the image planes. Triangulation is used to estimate the RCM position in 3D. Experiments were performed on a specially designed mockup to test the method.
RESULTS: The position of the pivot point is estimated with an average error less than 1.85 mm using two webcams placed from approximately 30 cm to 1 m away from the scene. The entire procedure was completed in a few seconds.
CONCLUSION: In automated method to estimate the ideal position of the RCM was shown to be reliable. The method can be implemented within a visual servoing approach to automatically place the RCM point, or the results can be displayed on a screen to provide guidance to the surgeon. Further work includes the development of an image-guided alignment method and validation with in vivo experiments.

Entities:  

Mesh:

Year:  2014        PMID: 24830535     DOI: 10.1007/s11548-014-1071-3

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  11 in total

1.  Trocar and instrument positioning system TISKA. An assist device for endoscopic solo surgery.

Authors:  M O Schurr; A Arezzo; B Neisius; H Rininsland; H U Hilzinger; J Dorn; K Roth; G F Buess
Journal:  Surg Endosc       Date:  1999-05       Impact factor: 4.584

2.  3D tracking of laparoscopic instruments using statistical and geometric modeling.

Authors:  Rémi Wolf; Josselin Duchateau; Philippe Cinquin; Sandrine Voros
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

3.  Design and preliminary in vivo validation of a robotic laparoscope holder for minimally invasive surgery.

Authors:  Benoît Herman; Bruno Dehez; Khanh Tran Duy; Benoît Raucent; Etienne Dombre; Sébastien Krut
Journal:  Int J Med Robot       Date:  2009-09       Impact factor: 2.547

4.  Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery.

Authors:  C Song; A Alijani; T Frank; G B Hanna; A Cuschieri
Journal:  Surg Endosc       Date:  2006-05-12       Impact factor: 4.584

5.  Abdominal wall thickness: is it associated with superficial and deep incisional surgical site infection after colorectal surgery?

Authors:  Mary R Kwaan; Anne Marie E Sirany; David A Rothenberger; Robert D Madoff
Journal:  Surg Infect (Larchmt)       Date:  2013-05-15       Impact factor: 2.150

6.  The spinal needle test effectively measures abdominal wall thickness before cannula placement at laparoscopy.

Authors:  Magdy P Milad; Mary Faith Terkildsen
Journal:  J Am Assoc Gynecol Laparosc       Date:  2002-11

Review 7.  Trocar site hernia after laparoscopic surgery: a qualitative systematic review.

Authors:  F Helgstrand; J Rosenberg; T Bisgaard
Journal:  Hernia       Date:  2010-12-09       Impact factor: 4.739

8.  Needle thoracostomy: implications of computed tomography chest wall thickness.

Authors:  Melissa L Givens; Karen Ayotte; Craig Manifold
Journal:  Acad Emerg Med       Date:  2004-02       Impact factor: 3.451

Review 9.  Trocar site hernia.

Authors:  Hitoshi Tonouchi; Yukinari Ohmori; Minako Kobayashi; Masato Kusunoki
Journal:  Arch Surg       Date:  2004-11

Review 10.  Obesity prevalence from a European perspective: a systematic review.

Authors:  Anne Berghöfer; Tobias Pischon; Thomas Reinhold; Caroline M Apovian; Arya M Sharma; Stefan N Willich
Journal:  BMC Public Health       Date:  2008-06-05       Impact factor: 3.295

View more
  2 in total

1.  Control of a hybrid robotic system for computer-assisted interventions in dynamic environments.

Authors:  Gabrijel Smoljkic; Gianni Borghesan; Alain Devreker; Emmanuel Vander Poorten; Benoit Rosa; Herbert De Praetere; Joris De Schutter; Dominiek Reynaerts; Jos Vander Sloten
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-12-11       Impact factor: 2.924

2.  ColibriDoc: An Eye-in-Hand Autonomous Trocar Docking System.

Authors:  Shervin Dehghani; Michael Sommersperger; Junjie Yang; Mehrdad Salehi; Benjamin Busam; Kai Huang; Peter Gehlbach; Iulian Iordachita; Nassir Navab; M Ali Nasseri
Journal:  IEEE Int Conf Robot Autom       Date:  2022-07-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.