Melissa L Givens1, Karen Ayotte, Craig Manifold. 1. Emergency Medicine Residency and Department of Radiology, San Antonio Uniformed Services Health Education Consortium, Brooke Army Medical Center/Wilford Hall Medical Center, San Antonio, TX 75390, USA. melissagivens@sbcglobal.net
Abstract
OBJECTIVES: To determine the length of catheter required to perform a needle thoracostomy, as determined by chest wall thickness, to treat the majority of patients presenting to the emergency department (ED) with a potential tension pneumothorax. METHODS: A convenience sample of 111 computed tomography (CT) scans of the chest in trauma and medical resuscitation patients at a military Level 1 trauma center in San Antonio, Texas, was pooled, and the chest wall thickness was measured at the second intercostal space, midclavicular line, to the nearest 0.1 cm. RESULTS: The mean chest wall thickness in the patients studied averaged 4.24 cm (95% confidence interval [CI] = 3.97 to 4.52). Nearly one fourth (25) of the study patients had a chest wall thicker than 5 cm. Women, on average, have thicker chest walls than men (4.90 for women; 4.16 for men; p = 0.022). CONCLUSIONS: In this study, a catheter length of 5 cm would reliably penetrate the pleural space of only 75% of patients. A longer catheter should be considered, especially in women.
OBJECTIVES: To determine the length of catheter required to perform a needle thoracostomy, as determined by chest wall thickness, to treat the majority of patients presenting to the emergency department (ED) with a potential tension pneumothorax. METHODS: A convenience sample of 111 computed tomography (CT) scans of the chest in trauma and medical resuscitation patients at a military Level 1 trauma center in San Antonio, Texas, was pooled, and the chest wall thickness was measured at the second intercostal space, midclavicular line, to the nearest 0.1 cm. RESULTS: The mean chest wall thickness in the patients studied averaged 4.24 cm (95% confidence interval [CI] = 3.97 to 4.52). Nearly one fourth (25) of the study patients had a chest wall thicker than 5 cm. Women, on average, have thicker chest walls than men (4.90 for women; 4.16 for men; p = 0.022). CONCLUSIONS: In this study, a catheter length of 5 cm would reliably penetrate the pleural space of only 75% of patients. A longer catheter should be considered, especially in women.
Authors: Chad G Ball; Amy D Wyrzykowski; Andrew W Kirkpatrick; Christopher J Dente; Jeffrey M Nicholas; Jeffrey P Salomone; Grace S Rozycki; John B Kortbeek; David V Feliciano Journal: Can J Surg Date: 2010-06 Impact factor: 2.089
Authors: Danuel V Laan; Trang Diem N Vu; Cornelius A Thiels; T K Pandian; Henry J Schiller; M Hassan Murad; Johnathon M Aho Journal: Injury Date: 2015-12-13 Impact factor: 2.586
Authors: Nimesh D Naik; Matthew C Hernandez; Jeff R Anderson; Erika K Ross; Martin D Zielinski; Johnathon M Aho Journal: Chest Date: 2017-05-10 Impact factor: 9.410