Literature DB >> 15933076

Patient exposure in medical X-ray imaging in Europe.

Dieter F Regulla1, Heinrich Eder.   

Abstract

Patients are exposed to X rays when undergoing medical examinations in diagnostic radiology. Exposure data acquired and assessed in Germany for the year 1997 resulted in a mean annual effective dose of 2 +/- 0.5 mSv per head of the population, thereby reaching or exceeding the average level of environmental radiation in many cases. The underlying frequency of medical X-ray examinations was approximately 136 million, i.e. approximately 1.7 examinations annually per head of the population. For comparison, corresponding data of other countries were extracted from the UNSCEAR 2000 report or originate from the literature. Data analysis shows significant differences in national radiological practices and a very uneven distribution of patient doses amongst the world population. The mean annual effective dose per head of the population varies by up to a factor of 60 between health care level I and IV countries, and still by a factor of approximately 6 within health care level I countries. While projection radiography has succeeded in reducing dose consumption, computed tomography and radiological interventions have given rise to a significant growth of patient exposure, and interventional radiology can even exceed thresholds for deterministic radiation effects. Patient exposure is further shown to result from misadministration and retakes of X-ray examinations, usually not registered, as well as from technical failures of X-ray facilities, which can cause significantly enhanced exposure times. Corresponding data are presented and comments are made on the international situation of non-harmonised data collection on patient exposure as well as of parameters affecting the assessment of exposure and risk.

Entities:  

Mesh:

Year:  2005        PMID: 15933076     DOI: 10.1093/rpd/nch538

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  22 in total

1.  Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008.

Authors:  P Catuzzo; S Aimonetto; F Zenone; G Fanelli; P Marchisio; T Meloni; M Pasquino; S Tofani
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

2.  [The management of osteoarthritis by general practitioners in Germany: comparison of self-reported behaviour with international guidelines].

Authors:  T Rosemann; S Joos; J Szecsenyi
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

Review 3.  [Referral guidelines in diagnostic imaging].

Authors:  G Pärtan; F Kainberger; F Frühwald
Journal:  Radiologe       Date:  2008-03       Impact factor: 0.635

4.  Age estimation for forensic purposes in Italy: ethical issues.

Authors:  Martina Focardi; Vilma Pinchi; Federica De Luca; Gian-Aristide Norelli
Journal:  Int J Legal Med       Date:  2014-03-16       Impact factor: 2.686

5.  Conversion coefficients for determining organ doses in paediatric spine radiography.

Authors:  Michael Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-02-09

Review 6.  European trends in radiology: investigating factors affecting the number of examinations and the effective dose.

Authors:  Hamidreza Masjedi; Mohammad Hosein Zare; Neda Keshavarz Siahpoush; Seid Kazem Razavi-Ratki; Fatemeh Alavi; Masoud Shabani
Journal:  Radiol Med       Date:  2019-12-16       Impact factor: 3.469

7.  Sustainability in the cardiac cath lab.

Authors:  Eugenio Picano; Gennaro Santoro; Eliseo Vano
Journal:  Int J Cardiovasc Imaging       Date:  2006-10-11       Impact factor: 2.357

8.  Diagnostic chest X-rays and breast cancer risk before age 50 years for BRCA1 and BRCA2 mutation carriers.

Authors:  Esther M John; Valerie McGuire; Duncan Thomas; Robert Haile; Hilmi Ozcelik; Roger L Milne; Anna Felberg; Dee W West; Alexander Miron; Julia A Knight; Mary Beth Terry; Mary Daly; Saundra S Buys; Irene L Andrulis; John L Hopper; Melissa C Southey; Graham G Giles; Carmel Apicella; Heather Thorne; Alice S Whittemore
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2013-07-12       Impact factor: 4.254

Review 9.  [Aspects of radiation protection during chest X-radiography].

Authors:  M C Seidenbusch; K Schneider
Journal:  Radiologe       Date:  2015-07       Impact factor: 0.635

10.  Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography.

Authors:  Michael C Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-05-08
View more