Literature DB >> 1611424

The Reference Man in diagnostic radiology dosimetry.

B A Lindskoug1.   

Abstract

Following the legislation for radiation protection in Europe, increasing interest has been given to patient dosimetry in diagnostic radiology. Dose comparisons between groups of patients have demonstrated considerable discrepancies. The equipment, as well as the procedures used, have been scrutinized in order to find the reasons for the variation and to reduce it. In this work, patient size and shape are considered in patient dose evaluations in diagnostic radiology. The size, shape and constitution of the patients are shown to relate exponentially to the energy imparted during examination of the trunk. The equivalent cylindrical diameter of the patient body is used as the independent variable. Exponential functions are created by linear regression. The ICRP Reference Man with an equivalent diameter of 22.9 cm is used as a body-size standard. A method is suggested by which coordinate transformations reduce data to a base line defined by the Reference Man. It is shown that the method reduces the range of energy imparted by between 30% and 60% for six common X-ray examinations of the trunk. Resulting data constitute a finer instrument for intercomparisons between hospitals for the same examination. Further, it is suggested that adipose tissues should not be included when detrimental effects of radiologic exposure are determined. The Reference Man, stripped of 10 kg subcutaneous adipose tissue, is used as the non-fat standard dimension corresponding to the equivalent cylindrical diameter 21.2 cm. The suggested method is used to estimate the fraction of energy imparted to vital organs only. The results show that the energy imparted is reduced by between 30% and 60% according to this model. Consequently, predicted deaths are reduced by the same amount.

Entities:  

Mesh:

Year:  1992        PMID: 1611424     DOI: 10.1259/0007-1285-65-773-431

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

2.  Conversion coefficients for determining organ doses in paediatric spine radiography.

Authors:  Michael Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-02-09

3.  Local diagnostic reference level based on size-specific dose estimates: assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children's hospital.

Authors:  Rumi Imai; Osamu Miyazaki; Tetsuya Horiuchi; Hideo Kurosawa; Shunsuke Nosaka
Journal:  Pediatr Radiol       Date:  2014-10-09

4.  Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography.

Authors:  Michael C Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-05-08

5.  Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria.

Authors:  Nnamdi N Jibiri; Christopher J Olowookere
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.