Literature DB >> 24803131

Impact of respiration gating on image integration guided atrial fibrillation ablation.

Emin Evren Özcan1, Gabor Szeplaki, Tamas Tahin, Istvan Osztheimer, Szabolcs Szilagyi, Astrid Apor, Pal Maurovich Horvath, Hajnalka Vago, Béla Merkely, Laszlo Geller.   

Abstract

BACKGROUND: Radiofrequency (RF) catheter ablation guided by electroanatomic mapping systems is an effective therapy for atrial fibrillation. However, it may be affected by respiration movements. The aim of this study was to determine the impact of respiratory gating on procedural parameters in patients undergoing catheter ablation of atrial fibrillation (AF). METHODS AND
RESULTS: One-hundred forty consecutive patients undergoing pulmonary vein isolation were admitted to study. Respiratory gating module (AccuResp algorithm, Carto3, Biosense Webster) was enabled in 70 patients and disabled in 70 patients during procedures. Successful pulmonary vein isolation and sinus rhythm were obtained in all patients. A significant reduction in total procedure times [median 77, interquartile range (IQR 66-95) min vs median 82 (IQR 72-104) min, p < 0.05] and fluoroscopy times [median 14 (IQR 9-17) min vs median 16 (IQR 12-22) min, p < 0.05] were observed in the respiratory gated group. Although ablation times (duration between the first and last ablation) were significantly shorter in respiratory gated group [median 37 (IQR 32-53) min vs median 48 (IQR 39-65) min, p < 0.05], total RF application durations were not different between two groups [median 1,554 (IQR 1,213-2,196) s vs median 1,802 (IQR 1,344-2,448) s, p = 0.11]. Difference in electroanatomical map reconstruction times was not significant [median 14 (IQR 12-16) min in gated group vs median 13 (IQR 10-18) min in nongated group, p = 0.19].
CONCLUSION: Respiratory gating significantly improves fluoroscopy and ablation times during electroanatomic mapping guided AF ablation. Respiratory gated maps may provide uninterrupted continuous ablation applications. Furthermore, using automatic respiratory gating module does not prolong mapping times.

Entities:  

Mesh:

Year:  2014        PMID: 24803131     DOI: 10.1007/s00392-014-0707-1

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  24 in total

1.  Radiation exposure of the operator during cardiac catheter ablation procedures.

Authors:  I Pantos; C Koukorava; E Nirgianaki; E Carinou; E Tzanalaridou; E P Efstathopoulos; D G Katritsis
Journal:  Radiat Prot Dosimetry       Date:  2012-01-10       Impact factor: 0.972

Review 2.  Cardiac image registration of the left atrium and pulmonary veins.

Authors:  Jasbir Sra; Shivani Ratnakumar
Journal:  Heart Rhythm       Date:  2007-12-04       Impact factor: 6.343

3.  Comment on the European guidelines for the management of atrial fibrillation.

Authors:  Samir M Said; Ruediger C Braun-Dullaeus
Journal:  Clin Res Cardiol       Date:  2011-01-11       Impact factor: 5.460

4.  Impact of respiration on electroanatomical mapping of the right atrium: implication for cavotricuspid isthmus ablation.

Authors:  Ermenegildo de Ruvo; Serena Dottori; Luigi Sciarra; Marco Rebecchi; Borrelli Alessio; Scarà Antonio; Lucia De Luca; Anna Maria Martino; Fabrizio Guarracini; Alessandro Fagagnini; Ernesto Lioy; Leonardo Calò
Journal:  J Interv Card Electrophysiol       Date:  2012-10-23       Impact factor: 1.900

5.  Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX).

Authors:  Heidi Luise Estner; Isabel Deisenhofer; Armin Luik; Gjin Ndrepepa; Christian von Bary; Bernhard Zrenner; Claus Schmitt
Journal:  Europace       Date:  2006-07-10       Impact factor: 5.214

6.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

7.  Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis.

Authors:  Efstathios P Efstathopoulos; Demosthenes G Katritsis; Sofia Kottou; Nectarios Kalivas; Efthalia Tzanalaridou; Eleftherios Giazitzoglou; Socrates Korovesis; Keith Faulkner
Journal:  Europace       Date:  2006-05-11       Impact factor: 5.214

8.  Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience.

Authors:  Giuseppe Stabile; Marco Scaglione; Maurizio del Greco; Roberto De Ponti; Maria Grazia Bongiorni; Franco Zoppo; Ezio Soldati; Raffaella Marazzi; Massimiliano Marini; Fiorenzo Gaita; Assunta Iuliano; Emanuele Bertaglia
Journal:  Europace       Date:  2011-09-04       Impact factor: 5.214

9.  Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system.

Authors:  Martin Rotter; Yoshihide Takahashi; Prashanthan Sanders; Michel Haïssaguerre; Pierre Jaïs; Li-Fern Hsu; Fréderic Sacher; Jean-Luc Pasquié; Jacques Clementy; Mélèze Hocini
Journal:  Eur Heart J       Date:  2005-03-01       Impact factor: 29.983

10.  Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge Italian Registry.

Authors:  Emanuele Bertaglia; Paolo Della Bella; Claudio Tondo; Alessandro Proclemer; Nicola Bottoni; Roberto De Ponti; Maurizio Landolina; Maria Grazia Bongiorni; Leonardo Corò; Giuseppe Stabile; Antonio Dello Russo; Roberto Verlato; Massimo Mantica; Franco Zoppo
Journal:  Europace       Date:  2009-06-18       Impact factor: 5.214

View more
  5 in total

1.  Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration.

Authors:  Gábor Széplaki; László Gellér; Emin Evren Özcan; Tamás Tahin; Orsolya Mária Kovács; Nóra Parázs; Júlia Karády; Pál Maurovich-Horvat; Szabolcs Szilágyi; István Osztheimer; Attila Tóth; Béla Merkely
Journal:  J Interv Card Electrophysiol       Date:  2016-01-27       Impact factor: 1.900

2.  Neuropsychological impact of cerebral microemboli in ablation of atrial fibrillation.

Authors:  S Kochhäuser; H H Lohmann; M A Ritter; P Leitz; F Güner; S Zellerhoff; C Korsukewitz; D G Dechering; J Banken; N M Peters; L Eckardt; G Mönnig
Journal:  Clin Res Cardiol       Date:  2014-10-22       Impact factor: 5.460

3.  Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation.

Authors:  Hisaki Makimoto; Christian-H Heeger; Tina Lin; Andreas Rillig; Andreas Metzner; Erik Wissner; Shibu Mathew; Sebastian Deiss; Peter Rausch; Christine Lemeš; Karl-Heinz Kuck; Feifan Ouyang; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2015-04-18       Impact factor: 5.460

4.  Catheter ablation of paroxysmal atrial fibrillation: circumferential pulmonary vein ablation: success rates with and without exclusion of areas adjacent to the esophagus.

Authors:  Klaus Kettering; Dag-Hau Yim; Alexander Benz; Felix Gramley
Journal:  Clin Res Cardiol       Date:  2017-05-10       Impact factor: 5.460

5.  Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation.

Authors:  Andreas Rillig; Tina Lin; Boris Schmidt; Britta Feige; Christian Heeger; Jascha Wegner; Erik Wissner; Andreas Metzner; Anita Arya; Shibu Mathew; Peter Wohlmuth; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2015-07-22       Impact factor: 5.460

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.