Literature DB >> 24802193

Role of ¹⁸F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: a prospective study.

Maddalena Graziosi1, Cristina Nanni, Massimiliano Lorenzini, Igor Diemberger, Rachele Bonfiglioli, Ferdinando Pasquale, Matteo Ziacchi, Mauro Biffi, Cristian Martignani, Michele Bartoletti, Fabio Tumietto, Giuseppe Boriani, Pier Luigi Viale, Stefano Fanti, Claudio Rapezzi.   

Abstract

PURPOSE: Infective endocarditis (IE) is widely underdiagnosed or diagnosed after a major delay. The diagnosis is currently based on the modified DUKE criteria, where the only validated imaging technique is echocardiography, and remains challenging especially in patients with an implantable cardiac device. The aim of this study was to assess the incremental diagnostic role of (18)F-FDG PET/CT in patients with an implanted cardiac device and suspected IE.
METHODS: We prospectively analysed 27 consecutive patients with an implantable device evaluated for suspected device-related IE between January 2011 and June 2013. The diagnostic probability of IE was defined at presentation according to the modified DUKE criteria. PET/CT was performed as soon as possible following the clinical suspicion of IE. Patients then underwent medical or surgical treatment based on the overall clinical evaluation. During follow-up, we considered: lead cultures in patients who underwent extraction, direct inspection and lead cultures in those who underwent surgery, and a clinical/instrumental reevaluation after at least 6 months in patients who received antimicrobial treatment or had an alternative diagnosis and were not treated for IE. After the follow-up period, the diagnosis was systematically reviewed by the multidisciplinary team using the modified DUKE criteria and considering the new findings.
RESULTS: Among the ten patients with a positive PET/CT scan, seven received a final diagnosis of "definite IE", one of "possible IE" and two of "IE rejected". Among the 17 patients with a negative PET/CT scan, four were false-negative and received a final diagnosis of definite IE. These patients underwent PET/CT after having started antibiotic therapy (≥48 h) or had a technically suboptimal examination.
CONCLUSION: In patients with a cardiac device, PET/CT increases the diagnostic accuracy of the modified Duke criteria for IE, particularly in the subset of patients with possible IE in whom it may help the clinician manage a challenging situation.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24802193     DOI: 10.1007/s00259-014-2773-z

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  34 in total

1.  Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis.

Authors:  J S Li; D J Sexton; N Mick; R Nettles; V G Fowler; T Ryan; T Bashore; G R Corey
Journal:  Clin Infect Dis       Date:  2000-04-03       Impact factor: 9.079

2.  Pacemaker lead infection: echocardiographic features, management, and outcome.

Authors:  F Victor; C De Place; C Camus; H Le Breton; C Leclercq; D Pavin; P Mabo; C Daubert
Journal:  Heart       Date:  1999-01       Impact factor: 5.994

3.  Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections.

Authors:  Jean-François Sarrazin; François Philippon; Michel Tessier; Jean Guimond; Franck Molin; Jean Champagne; Isabelle Nault; Louis Blier; Maxime Nadeau; Lyne Charbonneau; Mikaël Trottier; Gilles O'Hara
Journal:  J Am Coll Cardiol       Date:  2012-05-01       Impact factor: 24.094

4.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

5.  Factors influencing the sensitivity of 18F-FDG PET/CT in the detection of infective endocarditis.

Authors:  Giorgio Treglia; Francesco Bertagna
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-05-03       Impact factor: 9.236

6.  16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.

Authors:  Arnold J Greenspon; Jasmine D Patel; Edmund Lau; Jorge A Ochoa; Daniel R Frisch; Reginald T Ho; Behzad B Pavri; Steven M Kurtz
Journal:  J Am Coll Cardiol       Date:  2011-08-30       Impact factor: 24.094

7.  Usefulness of transesophageal echocardiography for diagnosis of infected transvenous permanent pacemakers.

Authors:  I Vilacosta; C Sarriá; J A San Román; J Jiménez; J A Castillo; E Iturralde; M J Rollán; L Martínez Elbal
Journal:  Circulation       Date:  1994-06       Impact factor: 29.690

8.  Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections.

Authors:  Muhammad R Sohail; Daniel Z Uslan; Akbar H Khan; Paul A Friedman; David L Hayes; Walter R Wilson; James M Steckelberg; Sarah Stoner; Larry M Baddour
Journal:  J Am Coll Cardiol       Date:  2007-04-23       Impact factor: 24.094

9.  Infective endocarditis complicating permanent pacemaker and implantable cardioverter-defibrillator infection.

Authors:  Muhammad R Sohail; Daniel Z Uslan; Akbar H Khan; Paul A Friedman; David L Hayes; Walter R Wilson; James M Steckelberg; Sarah M Jenkins; Larry M Baddour
Journal:  Mayo Clin Proc       Date:  2008-01       Impact factor: 7.616

10.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

Authors:  Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert
Journal:  Circulation       Date:  2010-01-04       Impact factor: 29.690

View more
  20 in total

1.  Quantifying FDG uptake to diagnose cardiac device infections: When and how should we do it?

Authors:  Ron Blankstein; Edward J Miller
Journal:  J Nucl Cardiol       Date:  2015-10-22       Impact factor: 5.952

Review 2.  18F-FDG-PET/CT Imaging to Diagnose Septic Emboli and Mycotic Aneurysms in Patients with Endocarditis and Cardiac Device Infections.

Authors:  Nidaa Mikail; Khadija Benali; Besma Mahida; Jonathan Vigne; Fabien Hyafil; François Rouzet; Dominique Le Guludec
Journal:  Curr Cardiol Rep       Date:  2018-03-06       Impact factor: 2.931

3.  Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Ajmal; Saira Farid; John C O'Horo; Panithaya Chareonthaitawee; Larry M Baddour; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-10-30       Impact factor: 5.952

4.  Recommendations on nuclear and multimodality imaging in IE and CIED infections.

Authors:  Paola Anna Erba; Patrizio Lancellotti; Isidre Vilacosta; Oliver Gaemperli; Francois Rouzet; Marcus Hacker; Alberto Signore; Riemer H J A Slart; Gilbert Habib
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-05-24       Impact factor: 9.236

Review 5.  18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

Authors:  A Roque; M N Pizzi; H Cuéllar-Calàbria; S Aguadé-Bruix
Journal:  Curr Cardiol Rep       Date:  2017-02       Impact factor: 2.931

6.  Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study.

Authors:  Igor Diemberger; Rachele Bonfiglioli; Cristian Martignani; Maddalena Graziosi; Mauro Biffi; Stefano Lorenzetti; Matteo Ziacchi; Cristina Nanni; Stefano Fanti; Giuseppe Boriani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-08       Impact factor: 9.236

7.  Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Farid; Saira Ajmal; Geoffrey B Johnson; Larry M Baddour; Panithaya Chareonthaitawee; Paul A Friedman; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-09-14       Impact factor: 5.952

8.  18F-FDG PET/CT now endorsed by guidelines across all types of CIED infection: Evidence limited but growing.

Authors:  Fozia Zahir Ahmed; Parthiban Arumugam
Journal:  J Nucl Cardiol       Date:  2017-11-29       Impact factor: 5.952

Review 9.  Accuracy of Positron Emission Tomography as a Diagnostic Tool for Lead Endocarditis: Design of the Prospective Multicentre ENDOTEP Study.

Authors:  Sana Amraoui; Ghoufrane Tlili; Elif Hindié; Paul Perez; Olivia Peuchant; Laurence Bordenave; Pierre Bordachar
Journal:  Eur Cardiol       Date:  2016-08

10.  Assessment of the diagnostic accuracy of 18F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria.

Authors:  Ana Jiménez-Ballvé; María Jesús Pérez-Castejón; Roberto C Delgado-Bolton; Cristina Sánchez-Enrique; Isidre Vilacosta; David Vivas; Carmen Olmos; Manuel E Fuentes Ferrer; José L Carreras-Delgado
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-09-05       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.