PURPOSE: To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. MATERIALS AND METHODS: CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. RESULTS: All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). CONCLUSION: The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. KEY POINTS: • AAA volumetry by semiautomated segmentation is accurate on CT following endovascular repair. • AAA volumetry by semiautomated segmentation is accurate on unenhanced CT. • Standardization of the segmentation technique maximizes the reproducibility of volume measurements.
PURPOSE: To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. MATERIALS AND METHODS: CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. RESULTS: All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). CONCLUSION: The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. KEY POINTS: • AAA volumetry by semiautomated segmentation is accurate on CT following endovascular repair. • AAA volumetry by semiautomated segmentation is accurate on unenhanced CT. • Standardization of the segmentation technique maximizes the reproducibility of volume measurements.
Authors: P Nambi; R Sengupta; Z Krajcer; R Muthupillai; N Strickman; B Y C Cheong Journal: Eur J Vasc Endovasc Surg Date: 2010-12-31 Impact factor: 7.069
Authors: Claude Kauffmann; An Tang; Eric Therasse; Marie-France Giroux; Stephane Elkouri; Philippe Melanson; Bertrand Melanson; Vincent L Oliva; Gilles Soulez Journal: Eur J Radiol Date: 2011-05-20 Impact factor: 3.528
Authors: A Canì; E Cotta; C Recaldini; D Lumia; F Fontana; G Carrafiello; V Colli; C Fugazzola Journal: Radiol Med Date: 2011-06-04 Impact factor: 3.469
Authors: Thorsten A Bley; Peter J Chase; Scott B Reeder; Christopher J François; Kazuhiko Shinki; Girma Tefera; Frank N Ranallo; Thomas M Grist; Myron Pozniak Journal: Radiology Date: 2009-07-31 Impact factor: 11.105
Authors: David C Brewster; Jack L Cronenwett; John W Hallett; K Wayne Johnston; William C Krupski; Jon S Matsumura Journal: J Vasc Surg Date: 2003-05 Impact factor: 4.268
Authors: Frank A Lederle; Julie A Freischlag; Tassos C Kyriakides; Jon S Matsumura; Frank T Padberg; Ted R Kohler; Panagiotis Kougias; Jessie M Jean-Claude; Dolores F Cikrit; Kathleen M Swanson Journal: N Engl J Med Date: 2012-11-22 Impact factor: 91.245
Authors: Christoph Artzner; Malte N Bongers; Rainer Kärgel; Sebastian Faby; Gerald Hefferman; Judith Herrmann; Svenja L Nopper; Regine M Perl; Sven S Walter Journal: Diagnostics (Basel) Date: 2022-07-23