Literature DB >> 24796955

Three-dimensional gamma analysis of dose distributions in individual structures for IMRT dose verification.

Yuuki Tomiyama1, Fujio Araki, Takeshi Oono, Kazunari Hioki.   

Abstract

Our purpose in this study was to implement three-dimensional (3D) gamma analysis for structures of interest such as the planning target volume (PTV) or clinical target volume (CTV), and organs at risk (OARs) for intensity-modulated radiation therapy (IMRT) dose verification. IMRT dose distributions for prostate and head and neck (HN) cancer patients were calculated with an analytical anisotropic algorithm in an Eclipse (Varian Medical Systems) treatment planning system (TPS) and by Monte Carlo (MC) simulation. The MC dose distributions were calculated with EGSnrc/BEAMnrc and DOSXYZnrc user codes under conditions identical to those for the TPS. The prescribed doses were 76 Gy/38 fractions with five-field IMRT for the prostate and 33 Gy/17 fractions with seven-field IMRT for the HN. TPS dose distributions were verified by the gamma passing rates for the whole calculated volume, PTV or CTV, and OARs by use of 3D gamma analysis with reference to MC dose distributions. The acceptance criteria for the 3D gamma analysis were 3/3 and 2 %/2 mm for a dose difference and a distance to agreement. The gamma passing rates in PTV and OARs for the prostate IMRT plan were close to 100 %. For the HN IMRT plan, the passing rates of 2 %/2 mm in CTV and OARs were substantially lower because inhomogeneous tissues such as bone and air in the HN are included in the calculation area. 3D gamma analysis for individual structures is useful for IMRT dose verification.

Entities:  

Mesh:

Year:  2014        PMID: 24796955     DOI: 10.1007/s12194-014-0266-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  21 in total

1.  A Monte Carlo study of radiation transport through multileaf collimators.

Authors:  J O Kim; J V Siebers; P J Keall; M R Arnfield; R Mohan
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

2.  A DICOM-RT-based toolbox for the evaluation and verification of radiotherapy plans.

Authors:  E Spezi; D G Lewis; C W Smith
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

3.  The design and testing of novel clinical parameters for dose comparison.

Authors:  Nathan L Childress; Isaac I Rosen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-08-01       Impact factor: 7.038

4.  Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans.

Authors:  Markus Stock; Bernhard Kroupa; Dietmar Georg
Journal:  Phys Med Biol       Date:  2005-02-07       Impact factor: 3.609

5.  Gamma histograms for radiotherapy plan evaluation.

Authors:  Emiliano Spezi; D Geraint Lewis
Journal:  Radiother Oncol       Date:  2006-05-11       Impact factor: 6.280

6.  Monte carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator.

Authors:  E Sterpin; M Tomsej; B De Smedt; N Reynaert; S Vynckier
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

7.  Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors.

Authors:  Benjamin E Nelms; Heming Zhen; Wolfgang A Tomé
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

8.  Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

Authors:  M Stasi; S Bresciani; A Miranti; A Maggio; V Sapino; P Gabriele
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

9.  Commissioning and quality assurance of treatment planning computers.

Authors:  J Van Dyk; R B Barnett; J E Cygler; P C Shragge
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-05-20       Impact factor: 7.038

10.  A dose gradient analysis tool for IMRT QA.

Authors:  Jean M Moran; Jeffrey Radawski; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2005-05-19       Impact factor: 2.102

View more
  2 in total

1.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01

2.  Dosimetric Evaluation of the QFix kVueTM Calypso Couch Top.

Authors:  Lingtong Hou; Huiqin Zhang; Xiaomei Sun; Qianqian Liu; Tingfeng Chen; Yong Liu; Xiaodong Jiang; Shengyu Yao
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.