Literature DB >> 12502045

A DICOM-RT-based toolbox for the evaluation and verification of radiotherapy plans.

E Spezi1, D G Lewis, C W Smith.   

Abstract

The verification of radiotherapy plans is an essential step in the treatment planning process. This is especially important for highly conformal and IMRT plans which produce non-intuitive fluence maps and complex 3D dose distributions. In this work we present a DICOM (Digital Imaging and Communication in Medicine) based toolbox, developed for the evaluation and the verification of radiotherapy treatment plans. The toolbox offers the possibility of importing treatment plans generated with different calculation algorithms and/or different optimization engines and evaluating dose distributions on an independent platform. Furthermore the radiotherapy set-up can be exported to the BEAM Monte Carlo code system for dose verification. This can be done by simulating the irradiation of the patient CT dataset or the irradiation of a software-generated water phantom. We show the application of some of the functions implemented in this toolbox for the evaluation and verification of an IMRT treatment of the head and neck region.

Entities:  

Mesh:

Year:  2002        PMID: 12502045     DOI: 10.1088/0031-9155/47/23/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Interface software for DOSXYZnrc Monte Carlo dose evaluation on a commercial radiation treatment planning system.

Authors:  Etsuo Kunieda; Hossain M Deloar; Shunji Takagi; Koichi Sato; Takatsugu Kawase; Hidetoshi Saitoh; Kimiaki Saito; Osamu Sato; Graham Sorell; Atsushi Kubo
Journal:  Radiat Med       Date:  2007-07-27

2.  Analysis of outcomes in radiation oncology: an integrated computational platform.

Authors:  Dezhi Liu; Munther Ajlouni; Jian-Yue Jin; Samuel Ryu; Farzan Siddiqui; Anushka Patel; Benjamin Movsas; Indrin J Chetty
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Three-dimensional gamma analysis of dose distributions in individual structures for IMRT dose verification.

Authors:  Yuuki Tomiyama; Fujio Araki; Takeshi Oono; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2014-05-06

4.  Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

Authors:  Ross McGurk; Joao Seco; Marco Riboldi; John Wolfgang; Paul Segars; Harald Paganetti
Journal:  Phys Med Biol       Date:  2010-02-16       Impact factor: 3.609

5.  Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.

Authors:  Parham Alaei; Emiliano Spezi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  A rapid communication from the AAPM Task Group 201: recommendations for the QA of external beam radiotherapy data transfer. AAPM TG 201: quality assurance of external beam radiotherapy data transfer.

Authors:  R Alfredo Siochi; Peter Balter; Charles D Bloch; Lakshmi Santanam; Kurt Blodgett; Bruce H Curran; Martijn Engelsman; Wenzheng Feng; Jim Mechalakos; Dan Pavord; Tom Simon; Steven Sutlieff; X Ronald Zhu
Journal:  J Appl Clin Med Phys       Date:  2010-12-04       Impact factor: 2.102

7.  Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions.

Authors:  Jarkko J Ojala; Mika K Kapanen; Simo J Hyödynmaa; Tuija K Wigren; Maunu A Pitkänen
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

8.  Investigating the effect of dental implant materials with different densities on radiotherapy dose distribution using Monte-Carlo simulation and pencil beam convolution algorithm.

Authors:  Oya Akyol; Bahar Dirican; Turkay Toklu; Hakan Eren; Turan Olgar
Journal:  Dentomaxillofac Radiol       Date:  2019-02-01       Impact factor: 2.419

9.  The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant - comparison with measurements and Monte Carlo calculations.

Authors:  Jarkko Ojala; Mika Kapanen; Petri Sipilä; Simo Hyödynmaa; Maunu Pitkänen
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

10.  A design of a DICOM-RT-based tool box for nonrigid 4D dose calculation.

Authors:  Victy Y W Wong; Colin R Baker; T W Leung; Stewart Y Tung
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.