Literature DB >> 24788492

An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs.

T Nomura1, M Naito, Y Nakamura, T Ida, D Kuroda, T Kobayashi, T Sakamoto, H Seo.   

Abstract

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer's method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer's method is the best for evaluating the anteversion of the acetabular component on plain radiographs.

Entities:  

Keywords:  Accuracy; Cup anteversion; Cup inclination; Plain radiograph; Reliability; Total hip replacement

Mesh:

Year:  2014        PMID: 24788492     DOI: 10.1302/0301-620X.96B.33013

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  19 in total

1.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

Review 2.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

3.  The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

Authors:  William S Murphy; Ho Hyun Yun; Brett Hayden; Jens H Kowal; Stephen B Murphy
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

4.  Magnetic resonance imaging evaluation of acetabular orientation in normal Chinese children.

Authors:  YiQiang Li; YuanZhong Liu; QingHe Zhou; WeiDong Chen; JingChun Li; LingJia Yu; HongWen Xu; DengHui Xie
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

5.  Accuracy of planar anteversion measurements using anteroposterior radiographs.

Authors:  Gwang Chul Lee; Sang Hong Lee; Sin Wook Kang; Hyung Seok Park; Suenghwan Jo
Journal:  BMC Musculoskelet Disord       Date:  2019-12-05       Impact factor: 2.362

6.  Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs.

Authors:  Sascha Beck; Robert J Martin; Theodor Patsalis; Manuel Burggraf; André Busch; Stefan Landgraeber; Wegner Alexander
Journal:  Orthop Rev (Pavia)       Date:  2019-12-02

7.  A Novel Method for Correcting Pelvic Tilt on Anteroposterior Pelvic Radiographs.

Authors:  Jeffrey M Muir; John Vincent; Joseph Schipper; Varsha D Gobin; Meinusha Govindarajan; Karlina Fiaes; Jonathan Vigdorchik
Journal:  Cureus       Date:  2019-12-02

8.  Validation of a Novel Software Measurement Tool for Total Hip Arthroplasty.

Authors:  Jeffrey M Muir; Kelly A Foley; Karlina Fiaes; Justin B Wagler; Milena Galaszewicz; Jessica R Benson; Michael P Bradley
Journal:  Cureus       Date:  2021-06-09

9.  The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs.

Authors:  Yang Soo Park; Won Chul Shin; Sang Min Lee; Sang Ho Kwak; Jung Yun Bae; Kuen Tak Suh
Journal:  J Orthop Surg Res       Date:  2018-04-02       Impact factor: 2.359

10.  Comparison of Total Hip Arthroplasty after Two Types of Failed Hip Preserving Procedures with Primary Total Hip Arthroplasty.

Authors:  Wei Zuo; Jin-Hui Ma; Wei Cui; Wan-Shou Guo; Wei Sun
Journal:  Orthop Surg       Date:  2020-01-20       Impact factor: 2.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.