OBJECTIVES: The present study assesses the accuracy of three-dimensional (3D) cone beam CT (CBCT) and intra-oral radiography (CR) in visualizing peri-implant bone compared with histology.
METHODS: 26 titanium dental implants were placed in dog jaws with chronic type vestibular defects. After a healing period of 2 and 8 weeks (n = 12 dogs) the animals were sacrificed. CBCT scans and CR of the specimen were recorded. Dissected blocks were prepared, and histomorphometric analysis was performed. Both modalities were measured twice by two observers and compared with histomorphometry regarding bone levels and thickness around implants as well as length and diameter of implants.
RESULTS: Measurements of CBCT correlated well with histomorphometry of the vestibular bone level, oral bone thickness and implant length (all p-values <0.05). Compared with histomorphometry, the mean differences between CBCT and histomorphometry were between 0.06 and 2.61 mm. Mesial bone level (MBL) and distal bone level (DBL) were underestimated by both CR and CBCT. CR and histology measurements were only significantly correlated for implant length measurements. All intraclass correlations were highly significant.
CONCLUSIONS: 3D CBCT provides usable information about bone in all dimensions around implants with varying accuracy. CR and CBCT perform similar in assessing MBL and DBL, but, within its limits, the CBCT can assess oral and buccal bone. Metallic artefacts limit the visualization quality of bone around implants and further research could elucidate the value of post-processing algorithms. When information about osseous perforation of implants is needed, CBCT may still provide clinically valuable information.

Entities:  

Keywords:  cone beam computed tomography; dental implants; digital intra-oral radiographs; osseo-integration

Mesh:

Substances:

Year:  2014        PMID: 24786136      PMCID: PMC4141670          DOI: 10.1259/dmfr.20130088

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  27 in total

1.  Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology.

Authors:  D A Tyndall; S L Brooks
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-05

2.  Impact of guided bone regeneration and defect dimension on wound healing at chemically modified hydrophilic titanium implant surfaces: an experimental study in dogs.

Authors:  Frank Schwarz; Ronald E Jung; Tim Fienitz; Marco Wieland; Jürgen Becker; Martin Sager
Journal:  J Clin Periodontol       Date:  2010-05       Impact factor: 8.728

3.  Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements.

Authors:  P Eickholz; E Hausmann
Journal:  Eur J Oral Sci       Date:  2000-02       Impact factor: 2.612

4.  Cone beam computed tomography.

Authors:  Bruce W Small
Journal:  Gen Dent       Date:  2007 May-Jun

5.  Comparison of cone-beam imaging with orthopantomography and computerized tomography for assessment in presurgical implant dentistry.

Authors:  Timo Dreiseidler; Robert A Mischkowski; Jörg Neugebauer; Lutz Ritter; Joachim E Zöller
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Mar-Apr       Impact factor: 2.804

6.  Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects.

Authors:  B Vandenberghe; R Jacobs; J Yang
Journal:  Dentomaxillofac Radiol       Date:  2008-07       Impact factor: 2.419

7.  Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography.

Authors:  S Patel; A Dawood; F Mannocci; R Wilson; T Pitt Ford
Journal:  Int Endod J       Date:  2009-03-02       Impact factor: 5.264

8.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

9.  Comparison of cone-beam computerized tomography and intraoral radiographs for determination of the periodontal ligament in a variable phantom.

Authors:  Pia-Merete Jervøe-Storm; Martin Hagner; Jörg Neugebauer; Lutz Ritter; Joachim E Zöller; Søren Jepsen; Matthias Frentzen
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-02

10.  Accuracy of linear measurement and the measurement limits of thin objects with cone beam computed tomography: effects of measurement directions and of phantom locations in the fields of view.

Authors:  Kimihiro Tsutsumi; Toru Chikui; Kazutoshi Okamura; Kazunori Yoshiura
Journal:  Int J Oral Maxillofac Implants       Date:  2011 Jan-Feb       Impact factor: 2.804

View more
  22 in total

1.  Ultrasonographic evaluation of edentulous crestal bone topography: A proof-of-principle retrospective study.

Authors:  Khaled Sinjab; Oliver D Kripfgans; Alice Ou; Hsun-Liang Chan
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2021-07-18

Review 2.  Clinical evaluation of osseointegration using resonance frequency analysis.

Authors:  Parth Satwalekar; Sandeep Nalla; Ramaswamy Reddy; Sheeba Glory Chowdary
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

Review 3.  Diagnostic Principles of Peri-Implantitis: a Systematic Review and Guidelines for Peri-Implantitis Diagnosis Proposal.

Authors:  Ausra Ramanauskaite; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

4.  Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study.

Authors:  Nicolau Silveira-Neto; Mateus Ericson Flores; João Paulo De Carli; Max Dória Costa; Felipe de Souza Matos; Luiz Renato Paranhos; Maria Salete Sandini Linden
Journal:  Clinics (Sao Paulo)       Date:  2017-11       Impact factor: 2.365

5.  Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs.

Authors:  Alexander Gröbe; Jan Semmusch; Maximilian Schöllchen; Henning Hanken; Michael Hahn; Wolfgang Eichhorn; Gerhard Schön; Ole Jung; Jamal M Stein; Aline Reitmeier; Max Heiland; Ralf Smeets; Clarissa Precht
Journal:  Biomed Res Int       Date:  2017-07-17       Impact factor: 3.411

6.  Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

Authors:  Shoaleh Shahidi; Barbad Zamiri; Masoud Abolvardi; Marzieh Akhlaghian; Maryam Paknahad
Journal:  J Dent (Shiraz)       Date:  2018-06

7.  A New Method of Measuring the Volumetric Change of Alveolar Bone Around Dental Implants Using Computed Tomography.

Authors:  Young-Wook Lim; Young-Jun Lim; Bongju Kim; Seung-Pyo Lee
Journal:  J Clin Med       Date:  2020-04-24       Impact factor: 4.241

8.  Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects.

Authors:  Jun Ho Kim; Reinaldo Abdala-Júnior; Luciana Munhoz; Arthur Rodriguez Gonzalez Cortes; Plauto Christopher Aranha Watanabe; Claudio Costa; Emiko Saito Arita
Journal:  Imaging Sci Dent       Date:  2020-06-18

9.  Functional investigation of bone implant viability using radiotracers in a new model of osteonecrosis.

Authors:  Luis Schiper; Bluma Linkowski Faintuch; Roberto José da Silva Badaró; Erica Aparecida de Oliveira; Victor E Arana Chavez; Elisangela Chinen; Joel Faintuch
Journal:  Clinics (Sao Paulo)       Date:  2016-10-01       Impact factor: 2.365

10.  Impact of bone defect morphology on the outcome of reconstructive treatment of peri-implantitis.

Authors:  Ahmad Aghazadeh; Rutger G Persson; Stefan Renvert
Journal:  Int J Implant Dent       Date:  2020-06-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.