Literature DB >> 24777559

Image reconstruction in k-space from MR data encoded with ambiguous gradient fields.

Gerrit Schultz1, Daniel Gallichan, Hans Weber, Walter R T Witschey, Matthias Honal, Jürgen Hennig, Maxim Zaitsev.   

Abstract

PURPOSE: In this work, the limits of image reconstruction in k-space are explored when non-bijective gradient fields are used for spatial encoding. THEORY: The image space analogy between parallel imaging and imaging with non-bijective encoding fields is partially broken in k-space. As a consequence, it is hypothesized and proven that ambiguities can only be resolved partially in k-space, and not completely as is the case in image space.
METHODS: Image-space and k-space based reconstruction algorithms for multi-channel radiofrequency data acquisitions are programmed and tested using numerical simulations as well as in vivo measurement data.
RESULTS: The hypothesis is verified based on an analysis of reconstructed images. It is found that non-bijective gradient fields have the effect that densely sampled autocalibration data, used for k-space reconstruction, provide less information than a separate scan of the receiver coil sensitivity maps, used for image space reconstruction. Consequently, in k-space only the undersampling artifact can be unfolded, whereas in image space, it is also possible to resolve aliasing that is caused by the non-bijectivity of the gradient fields.
CONCLUSION: For standard imaging, reconstruction in image space and in k-space is nearly equivalent, whereas there is a fundamental difference with practical consequences for the selection of image reconstruction algorithms when non-bijective encoding fields are involved.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  PatLoc; gradient; k-space; magnetic resonance imaging; nonlinear; reconstruction

Mesh:

Year:  2014        PMID: 24777559      PMCID: PMC4617561          DOI: 10.1002/mrm.25152

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data.

Authors:  Ernest N Yeh; Charles A McKenzie; Michael A Ohliger; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

3.  Advances in locally constrained k-space-based parallel MRI.

Authors:  Alexey A Samsonov; Walter F Block; Arjun Arunachalam; Aaron S Field
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

Review 4.  Encoding and reconstruction in parallel MRI.

Authors:  Klaas P Pruessmann
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

5.  Field-of-view limitations in parallel imaging.

Authors:  Mark A Griswold; Stephan Kannengiesser; Robin M Heidemann; Jianmin Wang; Peter M Jakob
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

6.  Block circulant quasi-band matrix property for the SENSE unfolding in k-space and justification for GRAPPA.

Authors:  Tian Liu; Bryan Kressler; Kang Wang; Yi Wang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

7.  General formulation for quantitative G-factor calculation in GRAPPA reconstructions.

Authors:  Felix A Breuer; Stephan A R Kannengiesser; Martin Blaimer; Nicole Seiberlich; Peter M Jakob; Mark A Griswold
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

8.  Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG.

Authors:  Nicole Seiberlich; Felix Breuer; Robin Heidemann; Martin Blaimer; Mark Griswold; Peter Jakob
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

9.  Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study.

Authors:  Juergen Hennig; Anna Masako Welz; Gerrit Schultz; Jan Korvink; Zhenyu Liu; Oliver Speck; Maxim Zaitsev
Journal:  MAGMA       Date:  2008-02-26       Impact factor: 2.310

10.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more
  3 in total

1.  Fast rotary nonlinear spatial acquisition (FRONSAC) imaging.

Authors:  Haifeng Wang; Leo K Tam; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Med       Date:  2015-05-07       Impact factor: 4.668

2.  Switching Circuit Optimization for Matrix Gradient Coils.

Authors:  Stefan Kroboth; Kelvin J Layton; Feng Jia; Sebastian Littin; Huijun Yu; Jürgen Hennig; Maxim Zaitsev
Journal:  Tomography       Date:  2019-06

3.  Clinical Potential of a New Approach to MRI Acceleration.

Authors:  Nadine L Dispenza; Sebastian Littin; Maxim Zaitsev; R Todd Constable; Gigi Galiana
Journal:  Sci Rep       Date:  2019-02-13       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.