Literature DB >> 15906283

Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data.

Ernest N Yeh1, Charles A McKenzie, Michael A Ohliger, Daniel K Sodickson.   

Abstract

A parallel image reconstruction algorithm is presented that exploits the k-space locality in radiofrequency (RF) coil encoded data. In RF coil encoding, information relevant to reconstructing an omitted datum rapidly diminishes as a function of k-space separation between the omitted datum and the acquired signal data. The proposed method, parallel magnetic resonance imaging with adaptive radius in k-space (PARS), harnesses this physical property of RF coil encoding via a sliding-kernel approach. Unlike generalized parallel imaging approaches that might typically involve inverting a prohibitively large matrix for arbitrary sampling trajectories, the PARS sliding-kernel approach creates manageable and distributable independent matrices to be inverted, achieving both computational efficiency and numerical stability. An empirical method designed to measure total error power is described, and the total error power of PARS reconstructions is studied over a range of k-space radii and accelerations, revealing "minimal-error" conditions at comparatively modest k-space radii. PARS reconstructions of undersampled in vivo Cartesian and non-Cartesian data sets are shown and are compared selectively with traditional SENSE reconstructions. Various characteristics of the PARS k-space locality constraint (such as the tradeoff between signal-to-noise ratio and artifact power and the relationship with iterative parallel conjugate gradient approaches or nonparallel gridding approaches) are discussed.

Entities:  

Mesh:

Year:  2005        PMID: 15906283     DOI: 10.1002/mrm.20490

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  K-space reconstruction with anisotropic kernel support (KARAOKE) for ultrafast partially parallel imaging.

Authors:  Jun Miao; Wilbur C K Wong; Sreenath Narayan; David L Wilson
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Parallel acquisition for effective density weighted imaging: PLANED imaging.

Authors:  Oliver M Geier; Dietbert Hahn; Herbert Köstler
Journal:  MAGMA       Date:  2007-01-20       Impact factor: 2.310

3.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

4.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

5.  Parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA).

Authors:  Chunlei Liu; Roland Bammer; Michael E Moseley
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

Review 6.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

7.  Multiple-Input Multiple-Output (MIMO) MRI: Combining Parallel Excitation and Parallel Reception for Enhanced Imaging.

Authors:  Xianglun Mao; Nicole L Vike; Thomas M Talavage; Joseph V Rispoli; David J Love
Journal:  IEEE Trans Comput Imaging       Date:  2019-03-13

Review 8.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

9.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

10.  Image reconstruction in k-space from MR data encoded with ambiguous gradient fields.

Authors:  Gerrit Schultz; Daniel Gallichan; Hans Weber; Walter R T Witschey; Matthias Honal; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2014-04-28       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.