Segmentation accuracy of long bones.

Joyce Van den Broeck1, Evie Vereecke2, Roel Wirix-Speetjens3, Jos Vander Sloten4.   

Abstract

The use of three-dimensional imaging methodologies in new applications in the orthopaedic field has introduced a need for high accuracy, in addition to a correct diagnosis. The aim of this study was to quantify the absolute dimensional errors between models reconstructed from computed tomography and magnetic resonance images compared to a ground truth for various regions of the bone. Clinical CT and MRI scans were acquired from nine lower leg cadavers and the bones were subsequently cleaned from soft tissues. 3D models of the tibia were created from the segmented CT and MRI images and compared to optical scans of the cleaned bones (considered as ground truth). The 3D reconstruction using CT images resulted in an RMS error of 0.55 mm, corresponding to an overestimated CT bone model compared to the cleaned bone. MR imaging resulted in an RMS error of 0.56 mm; however, the MRI bone model was on average a small underestimation of the cleaned bone. Different regions of the bones were analysed, indicating a difference in accuracy between diaphysis and epiphysis. This study demonstrates a high accuracy for both CT and MRI imaging, supporting the feasibility of using MRI technology for the 3D reconstruction of bones in medical applications.
Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Keywords:  Imaging accuracy; Medical imaging; Orthopaedics; Three-dimensional imaging

Mesh:

Year:  2014        PMID: 24768087     DOI: 10.1016/j.medengphy.2014.03.016

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  20 in total

1.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

2.  Aortic root sizing for transcatheter aortic valve implantation using a shape model parameterisation.

Authors:  Bart Bosmans; Toon Huysmans; Patricia Lopes; Eva Verhoelst; Tim Dezutter; Peter de Jaegere; Jan Sijbers; Jos Vander Sloten; Johan Bosmans
Journal:  Med Biol Eng Comput       Date:  2019-10       Impact factor: 2.602

3.  The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing.

Authors:  Maureen van Eijnatten; Erik-Jan Rijkhorst; Mark Hofman; Tymour Forouzanfar; Jan Wolff
Journal:  Dentomaxillofac Radiol       Date:  2016-03-04       Impact factor: 2.419

4.  Reliability and correlation analysis of computed methods to convert conventional 2D radiological hindfoot measurements to a 3D setting using weightbearing CT.

Authors:  A Burssens; J Peeters; M Peiffer; R Marien; T Lenaerts; G Vandeputte; J Victor
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-09       Impact factor: 2.924

5.  Which Two-dimensional Radiographic Measurements of Cam Femoroacetabular Impingement Best Describe the Three-dimensional Shape of the Proximal Femur?

Authors:  Penny R Atkins; YoungJae Shin; Praful Agrawal; Shireen Y Elhabian; Ross T Whitaker; Jeffrey A Weiss; Stephen K Aoki; Christopher L Peters; Andrew E Anderson
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

6.  Evaluation of errors in measurements of infantile hip radiograph using digitally reconstructed radiograph from three-dimensional MRI.

Authors:  Daisuke Hamano; Kiyoshi Yoshida; Chikahisa Higuchi; Dai Otsuki; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  J Orthop       Date:  2019-05-09

7.  Comparison of cartilage and bone morphological models of the ankle joint derived from different medical imaging technologies.

Authors:  Gilda Durastanti; Alberto Leardini; Sorin Siegler; Stefano Durante; Alberto Bazzocchi; Claudio Belvedere
Journal:  Quant Imaging Med Surg       Date:  2019-08

8.  Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models.

Authors:  Marco Gatti; Aurelio Cosentino; Erik Cura Stura; Laura Bergamasco; Domenica Garabello; Giovanni Pennisi; Mattia Puppo; Stefano Salizzoni; Simona Veglia; Ottavio Davini; Mauro Rinaldi; Paolo Fonio; Riccardo Faletti
Journal:  Int J Cardiovasc Imaging       Date:  2020-05-30       Impact factor: 2.357

9.  Three-Dimensional Evaluation of Similarity of Right and Left Knee Joints.

Authors:  Ki-Mo Jang; Jong-Hoon Park; Minho Chang; Youngjun Kim; Deukhee Lee; Sehyung Park; Joon Ho Wang
Journal:  Knee Surg Relat Res       Date:  2017-12-01

10.  The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion.

Authors:  Piotr Luczkiewicz; Karol Daszkiewicz; Wojciech Witkowski; Jacek Chróścielewski; Tomasz Ferenc; Boguslaw Baczkowski
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.