Literature DB >> 26943179

The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing.

Maureen van Eijnatten1, Erik-Jan Rijkhorst2, Mark Hofman2, Tymour Forouzanfar1, Jan Wolff1.   

Abstract

OBJECTIVES: Additively manufactured bone models, implants and drill guides are becoming increasingly popular amongst maxillofacial surgeons and dentists. To date, such constructs are commonly manufactured using CT technology that induces ionizing radiation. Recently, ultrashort echo time (UTE) MRI sequences have been developed that allow radiation-free imaging of facial bones. The aim of the present study was to assess the feasibility of UTE MRI sequences for medical additive manufacturing (AM).
METHODS: Three morphologically different dry human mandibles were scanned using a CT and MRI scanner. Additionally, optical scans of all three mandibles were made to acquire a "gold standard". All CT and MRI scans were converted into Standard Tessellation Language (STL) models and geometrically compared with the gold standard. To quantify the accuracy of the AM process, the CT, MRI and gold-standard STL models of one of the mandibles were additively manufactured, optically scanned and compared with the original gold-standard STL model.
RESULTS: Geometric differences between all three CT-derived STL models and the gold standard were <1.0 mm. All three MRI-derived STL models generally presented deviations <1.5 mm in the symphyseal and mandibular area. The AM process introduced minor deviations of <0.5 mm.
CONCLUSIONS: This study demonstrates that MRI using UTE sequences is a feasible alternative to CT in generating STL models of the mandible and would therefore be suitable for surgical planning and AM. Further in vivo studies are necessary to assess the usability of UTE MRI sequences in clinical settings.

Entities:  

Keywords:  X-ray computed; dimensional measurement accuracy; magnetic resonance imaging; printing; three-dimensional; tomography

Mesh:

Year:  2016        PMID: 26943179      PMCID: PMC5084702          DOI: 10.1259/dmfr.20150424

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  31 in total

1.  3D printing based on imaging data: review of medical applications.

Authors:  F Rengier; A Mehndiratta; H von Tengg-Kobligk; C M Zechmann; R Unterhinninghofen; H-U Kauczor; F L Giesel
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-05-15       Impact factor: 2.924

2.  MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

Authors:  Vincent Keereman; Yves Fierens; Tom Broux; Yves De Deene; Max Lonneux; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2010-05       Impact factor: 10.057

Review 3.  Update on mandibular reconstruction: computer-aided design, imaging, stem cells and future applications.

Authors:  Risto Kontio
Journal:  Curr Opin Otolaryngol Head Neck Surg       Date:  2014-08       Impact factor: 2.064

4.  Computed tomography-based virtual fracture reduction techniques in bimandibular fractures.

Authors:  Jan Oliver Voss; Viktor Varjas; Jan-Dirk Raguse; Nadine Thieme; R Geoff Richards; Lukas Kamer
Journal:  J Craniomaxillofac Surg       Date:  2015-12-01       Impact factor: 2.078

5.  Navigation-guided en bloc resection and defect reconstruction of craniomaxillary bony tumours.

Authors:  H Yu; X Wang; S Zhang; L Zhang; P Xin; S G Shen
Journal:  Int J Oral Maxillofac Surg       Date:  2013-07-01       Impact factor: 2.789

6.  Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging.

Authors:  R Adam Horch; Jeffry S Nyman; Daniel F Gochberg; Richard D Dortch; Mark D Does
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

7.  Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Michael A Moore; Randheer Shailam; Bob Liu; Thomas L Toth; Ellen Grant; Sjirk J Westra
Journal:  Radiology       Date:  2009-05-12       Impact factor: 11.105

8.  Magnetic resonance imaging: an accurate, radiation-free, alternative to computed tomography for the primary imaging and three-dimensional reconstruction of the bony orbit.

Authors:  Beat Schmutz; Benjamin Rahmel; Zeb McNamara; Alan Coulthard; Michael Schuetz; Anthony Lynham
Journal:  J Oral Maxillofac Surg       Date:  2013-11-20       Impact factor: 1.895

9.  Low-dose CT scan screening for lung cancer: comparison of images and radiation doses between low-dose CT and follow-up standard diagnostic CT.

Authors:  Koji Ono; Toru Hiraoka; Asami Ono; Eiji Komatsu; Takehiko Shigenaga; Hajime Takaki; Toru Maeda; Hiroyuki Ogusu; Shintaro Yoshida; Kiyoyasu Fukushima; Michiaki Kai
Journal:  Springerplus       Date:  2013-08-21

10.  Feasibility of volumetric MRI-guided high intensity focused ultrasound (MR-HIFU) for painful bone metastases.

Authors:  Merel Huisman; Mie K Lam; Lambertus W Bartels; Robbert J Nijenhuis; Chrit T Moonen; Floor M Knuttel; Helena M Verkooijen; Marco van Vulpen; Maurice A van den Bosch
Journal:  J Ther Ultrasound       Date:  2014-10-10
View more
  2 in total

Review 1.  Measuring and Establishing the Accuracy and Reproducibility of 3D Printed Medical Models.

Authors:  Elizabeth George; Peter Liacouras; Frank J Rybicki; Dimitrios Mitsouras
Journal:  Radiographics       Date:  2017-08-11       Impact factor: 5.333

2.  MRI and Additive Manufacturing of Nasal Alar Constructs for Patient-specific Reconstruction.

Authors:  Dafydd O Visscher; Maureen van Eijnatten; Niels P T J Liberton; Jan Wolff; Mark B M Hofman; Marco N Helder; J Peter W Don Griot; Paul P M van Zuijlen
Journal:  Sci Rep       Date:  2017-08-30       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.