Literature DB >> 31353427

Aortic root sizing for transcatheter aortic valve implantation using a shape model parameterisation.

Bart Bosmans1,2,3, Toon Huysmans4,5, Patricia Lopes6,7,8, Eva Verhoelst7, Tim Dezutter9,10, Peter de Jaegere11, Jan Sijbers8, Jos Vander Sloten6, Johan Bosmans12.   

Abstract

During a transcatheter aortic valve implantation, an axisymmetric implant is placed in an irregularly shaped aortic root. Implanting an incorrect size can cause complications such as leakage of blood alongside or through the implant. The aim of this study was to construct a method that determines the optimal size of the implant based on the three-dimensional shape of the aortic root. Based on the pre-interventional computed tomography scan of 89 patients, a statistical shape model of their aortic root was constructed. The weights associated with the principal components and the volume of calcification in the aortic valve were used as parameters in a classification algorithm. The classification algorithm was trained using the patients with no or mild leakage after their intervention. Subsequently, the algorithms were applied to the patients with moderate to severe leakage. Cross validation showed that a random forest classifier assigned the same size in 65 ± 7% of the training cases, while 57 ± 8% of the patients with moderate to severe leakage were assigned a different size. This initial study showed that this semi-automatic method has the potential to correctly assign an implant size. Further research is required to assess whether the different size implants would improve the outcome of those patients.

Entities:  

Keywords:  Aortic root sizing; Statistical shape modelling; Transcatheter aortic valve implantation

Mesh:

Year:  2019        PMID: 31353427     DOI: 10.1007/s11517-019-01996-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

1.  LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE: TECHNIC, INDICATIONS AND INTERPRETATIONS IN 700 CASES.

Authors:  R D SELLERS; M J LEVY; K AMPLATZ; C W LILLEHEI
Journal:  Am J Cardiol       Date:  1964-10       Impact factor: 2.778

2.  A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation.

Authors:  Bart Bosmans; Nele Famaey; Eva Verhoelst; Johan Bosmans; Jos Vander Sloten
Journal:  J Biomech       Date:  2016-06-23       Impact factor: 2.712

3.  A comprehensive shape model of the heart.

Authors:  Cristian Lorenz; Jens von Berg
Journal:  Med Image Anal       Date:  2006-05-18       Impact factor: 8.545

Review 4.  Computational cardiac atlases: from patient to population and back.

Authors:  Alistair A Young; Alejandro F Frangi
Journal:  Exp Physiol       Date:  2008-12-19       Impact factor: 2.969

5.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?

Authors:  Carl J Schultz; Adriaan Moelker; Nicolo Piazza; Apostolos Tzikas; Amber Otten; Rutger J Nuis; Lisan A Neefjes; Robert J van Geuns; Pim de Feyter; Gabriel Krestin; Patrick W Serruys; Peter P T de Jaegere
Journal:  Eur Heart J       Date:  2009-12-07       Impact factor: 29.983

6.  Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation.

Authors:  Kentaro Hayashida; Erik Bouvier; Thierry Lefèvre; Thomas Hovasse; Marie-Claude Morice; Bernard Chevalier; Mauro Romano; Philippe Garot; Darren Mylotte; Arnaud Farge; Patrick Donzeau-Gouge; Bertrand Cormier
Journal:  EuroIntervention       Date:  2012-09       Impact factor: 6.534

7.  Morphological Characteristics and Calcification of the Native Aortic Valve and the Relation to Significant Aortic Regurgitation after CoreValve TAVI.

Authors:  Bart Bosmans; Valérie Collas; Eva Verhoelst; Bernard Paelinck; Jos Vander Sloten; Johan Bosmans
Journal:  J Heart Valve Dis       Date:  2016-07

8.  Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.

Authors:  Delphine Détaint; Laurent Lepage; Dominique Himbert; Eric Brochet; David Messika-Zeitoun; Bernard Iung; Alec Vahanian
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

9.  Ventricular shape biomarkers for Alzheimer's disease in clinical MR images.

Authors:  Luca Ferrarini; Walter M Palm; Hans Olofsen; Roald van der Landen; Mark A van Buchem; Johan H C Reiber; Faiza Admiraal-Behloul
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

10.  Aortic valve replacement in octogenarians.

Authors:  Amal K Bose; James D Aitchison; John H Dark
Journal:  J Cardiothorac Surg       Date:  2007-07-13       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.