PURPOSE: Lung morphometry with hyperpolarized gas diffusion MRI is a highly sensitive technique for the noninvasive measurement of acinar microstructural parameters traditionally only accessible by histology. The goal of this work is to establish the reproducibility of these measurements in healthy volunteers and their dependence on the direction of the applied diffusion-sensitizing gradient. METHODS: Hyperpolarized helium-3 ((3) He) lung morphometry MRI was performed on a total of five healthy subjects. Two subjects received duplicate imaging on the same day and three subjects received duplicate imaging after a 4-month or 27-month delay to assess reproducibility. Four subjects repeated the measurement during the same session with different diffusion-sensitizing gradient directions to determine the effect on the parameter estimates. RESULTS: The (3) He lung morphometry measurements were reproducible over the short term and long term (e.g., % coefficient of variation [CV] of mean chord length, Lm = 2.1% and 2.9%, respectively) and across different diffusion gradient directions (Lm % CV = 2.6%). Results also show independence of field inhomogeneity effects at 1.5T. CONCLUSION: (3) He lung morphometry is a reproducible technique for measuring acinar microstructure and is effectively independent of the choice of diffusion gradient direction. This provides confidence for the use of this technique to compare populations and treatment efficacy.
PURPOSE: Lung morphometry with hyperpolarized gas diffusion MRI is a highly sensitive technique for the noninvasive measurement of acinar microstructural parameters traditionally only accessible by histology. The goal of this work is to establish the reproducibility of these measurements in healthy volunteers and their dependence on the direction of the applied diffusion-sensitizing gradient. METHODS: Hyperpolarized helium-3 ((3) He) lung morphometry MRI was performed on a total of five healthy subjects. Two subjects received duplicate imaging on the same day and three subjects received duplicate imaging after a 4-month or 27-month delay to assess reproducibility. Four subjects repeated the measurement during the same session with different diffusion-sensitizing gradient directions to determine the effect on the parameter estimates. RESULTS: The (3) He lung morphometry measurements were reproducible over the short term and long term (e.g., % coefficient of variation [CV] of mean chord length, Lm = 2.1% and 2.9%, respectively) and across different diffusion gradient directions (Lm % CV = 2.6%). Results also show independence of field inhomogeneity effects at 1.5T. CONCLUSION: (3) He lung morphometry is a reproducible technique for measuring acinar microstructure and is effectively independent of the choice of diffusion gradient direction. This provides confidence for the use of this technique to compare populations and treatment efficacy.
Authors: Andreas E Morbach; Klaus K Gast; Jörg Schmiedeskamp; Anja Dahmen; Annette Herweling; Claus P Heussel; Hans-Ulrich Kauczor; Wolfgang G Schreiber Journal: J Magn Reson Imaging Date: 2005-06 Impact factor: 4.813
Authors: Wolfgang G Schreiber; Andreas E Morbach; Trine Stavngaard; Klaus K Gast; Anette Herweling; Lise Vejby Søgaard; Michael Windirsch; Jörg Schmiedeskamp; Claus Peter Heussel; Hans-Ulrich Kauczor Journal: Respir Physiol Neurobiol Date: 2005-08-25 Impact factor: 1.931
Authors: Alexander L Sukstanskii; G Larry Bretthorst; Yulin V Chang; Mark S Conradi; Dmitriy A Yablonskiy Journal: J Magn Reson Date: 2006-10-09 Impact factor: 2.229
Authors: Dmitriy A Yablonskiy; Alexander L Sukstanskii; Jason C Leawoods; David S Gierada; G Larry Bretthorst; Stephen S Lefrak; Joel D Cooper; Mark S Conradi Journal: Proc Natl Acad Sci U S A Date: 2002-02-26 Impact factor: 11.205
Authors: Dmitriy A Yablonskiy; Alexander L Sukstanskii; James D Quirk; Jason C Woods; Mark S Conradi Journal: Magn Reson Med Date: 2014-02 Impact factor: 4.668
Authors: Robert P Thomen; Laura L Walkup; David J Roach; Zackary I Cleveland; John P Clancy; Jason C Woods Journal: J Cyst Fibros Date: 2016-07-29 Impact factor: 5.482
Authors: James D Quirk; Alexander L Sukstanskii; Jason C Woods; Barbara A Lutey; Mark S Conradi; David S Gierada; Roger D Yusen; Mario Castro; Dmitriy A Yablonskiy Journal: J Appl Physiol (1985) Date: 2015-11-05
Authors: Abdullah S Bdaiwi; Peter J Niedbalski; Md M Hossain; Matthew M Willmering; Laura L Walkup; Hui Wang; Robert P Thomen; Kai Ruppert; Jason C Woods; Zackary I Cleveland Journal: NMR Biomed Date: 2021-11-02 Impact factor: 4.044
Authors: Robert P Thomen; Jason C Woods; Peter F Sturm; Viral Jain; Laura L Walkup; Nara S Higano; James D Quirk; Brian M Varisco Journal: PLoS One Date: 2020-10-08 Impact factor: 3.240
Authors: Felix T Kurz; Thomas Kampf; Lukas R Buschle; Heinz-Peter Schlemmer; Sabine Heiland; Martin Bendszus; Christian H Ziener Journal: PLoS One Date: 2015-11-06 Impact factor: 3.240