Assessment of lung microstructure with magnetic resonance imaging of hyperpolarized Helium-3.

Wolfgang G Schreiber1, Andreas E Morbach, Trine Stavngaard, Klaus K Gast, Anette Herweling, Lise Vejby Søgaard, Michael Windirsch, Jörg Schmiedeskamp, Claus Peter Heussel, Hans-Ulrich Kauczor.   

Abstract

Magnetic resonance imaging of the apparent diffusion coefficient (ADC) of hyperpolarized Helium-3 is a new technique for probing pulmonary microstructure in vivo. The aim of this study was the assessment of potential sources of systematic errors of the ADC measurement. The influence of macroscopic motion was determined by measurements at two different delays after initiating the breath-hold, and before and after cardiac arrest. An intercentre comparison was performed in two age- and lung function-matched groups of lung-healthy volunteers at two research sites. Moreover, measurements of diffusion anisotropy were performed. We found no dependency of the ADC as a function of the delay after stop of inspiration. The influence of cardiac motion was less than 10%. In the intercentre comparison study, an excellent agreement between the two sites was found. First measurements of the diffusion tensor of intrapulmonary Helium-3 are shown.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15967737     DOI: 10.1016/j.resp.2005.05.002

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  13 in total

Review 1.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

2.  Volumetric dynamic oxygen-enhanced MRI (OE-MRI): comparison with CT Brody score and lung function in cystic fibrosis patients.

Authors:  K Martini; C M Gygax; C Benden; A R Morgan; G J M Parker; T Frauenfelder
Journal:  Eur Radiol       Date:  2018-04-13       Impact factor: 5.315

3.  Random walk simulation of the MRI apparent diffusion coefficient in a geometrical model of the acinar tree.

Authors:  José M Pérez-Sánchez; Ignacio Rodríguez; Jesús Ruiz-Cabello
Journal:  Biophys J       Date:  2009-07-22       Impact factor: 4.033

4.  In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction.

Authors:  James D Quirk; Yulin V Chang; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

5.  Regional correlation of emphysematous changes in lung function and structure: a comparison between pulmonary function testing and hyperpolarized MRI metrics.

Authors:  Kiarash Emami; Elaine Chia; Stephen Kadlecek; John P Macduffie-Woodburn; Jianliang Zhu; Stephen Pickup; Allison Blum; Masaru Ishii; Rahim R Rizi
Journal:  J Appl Physiol (1985)       Date:  2010-09-30

6.  Quantitative assessment of lung microstructure in healthy mice using an MR-based 3He lung morphometry technique.

Authors:  E Osmanagic; A L Sukstanskii; J D Quirk; J C Woods; R A Pierce; M S Conradi; E R Weibel; D A Yablonskiy
Journal:  J Appl Physiol (1985)       Date:  2010-08-26

7.  Regional anisotropy of airspace orientation in the lung as assessed with hyperpolarized helium-3 diffusion MRI.

Authors:  Peter Komlosi; Talissa A Altes; Kun Qing; Karen E Mooney; G Wilson Miller; Jaime F Mata; Eduard E de Lange; William A Tobias; Gordon D Cates; James R Brookeman; John P Mugler
Journal:  J Magn Reson Imaging       Date:  2015-05-26       Impact factor: 4.813

8.  Effects of diffusion time on short-range hyperpolarized (3)He diffusivity measurements in emphysema.

Authors:  David S Gierada; Jason C Woods; Andrew J Bierhals; Seth T Bartel; Jon H Ritter; Cliff K Choong; Nitin A Das; Cheng Hong; Thomas K Pilgram; Yulin V Chang; Richard E Jacob; James C Hogg; Richard J Battafarano; Joel D Cooper; Bryan F Meyers; G Alexander Patterson; Dmitriy A Yablonskiy; Mark S Conradi
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

9.  Oxygen-sensitive 3He-MRI in bronchiolitis obliterans after lung transplantation.

Authors:  Klaus Kurt Gast; Alexander Biedermann; Annette Herweling; Wolfgang Günter Schreiber; Jörg Schmiedeskamp; Eckhard Mayer; Claus Peter Heussel; Klaus Markstaller; Hans-Ulrich Kauczor; Balthasar Eberle
Journal:  Eur Radiol       Date:  2007-10-10       Impact factor: 5.315

10.  Hyperpolarized 3He MR imaging: physiologic monitoring observations and safety considerations in 100 consecutive subjects.

Authors:  Barbara A Lutey; Stephen S Lefrak; Jason C Woods; Tariq Tanoli; James D Quirk; Adil Bashir; Dmitriy A Yablonskiy; Mark S Conradi; Seth T Bartel; Thomas K Pilgram; Joel D Cooper; David S Gierada
Journal:  Radiology       Date:  2008-08       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.