PURPOSE: To measure the apparent diffusion coefficient (ADC) of hyperpolarized (HP) (3)He gas using diffusion weighted MRI in healthy volunteers and patients with emphysema and examine the reproducibility and volume dependency.
MATERIALS AND METHODS: A total of eight healthy volunteers and 16 patients with emphysema were examined after inhalation of HP (3)He gas mixed with nitrogen (N(2)) during breathhold starting from functional residual capacity (FRC) in supine position. Coronal diffusion-sensitized MR images were acquired. Each subject was imaged on three separate days over a seven-day period and received two different volumes (6% and 15% of total lung capacity [TLC]) of HP (3)He each day. ADC maps and histograms were calculated. The mean and standard deviation (SD) of the ADC at different days and volumes were compared.
RESULTS: The reproducibility of the mean ADC and SD over several days was good in both healthy volunteers and patients (SD range of 0.003-0.013 cm(2)/second and 0.001-0.009 cm(2)/second at 6% and 15% of TLC for healthy volunteers, and a SD range of 0.001-0.041 cm(2)/second and 0.001-0.011 cm(2)/second, respectively, for patients). A minor but significant increase in mean ADC with increased inhaled gas volume was observed in both groups.
CONCLUSION: Mean ADC and SD of HP (3)He MRI is reproducible and discriminates well between healthy controls and patients with emphysema at the higher gas volume. This method is robust and may be useful to gain new insights into the pathophysiology and course of emphysema. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18344208     DOI: 10.1002/jmri.21212

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  24 in total

Review 1.  Lung imaging in asthmatic patients: the picture is clearer.

Authors:  Mario Castro; Sean B Fain; Eric A Hoffman; David S Gierada; Serpil C Erzurum; Sally Wenzel
Journal:  J Allergy Clin Immunol       Date:  2011-06-02       Impact factor: 10.793

2.  In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction.

Authors:  James D Quirk; Yulin V Chang; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

3.  Measuring diffusion limitation with a perfusion-limited gas--hyperpolarized 129Xe gas-transfer spectroscopy in patients with idiopathic pulmonary fibrosis.

Authors:  S Sivaram Kaushik; Matthew S Freeman; Suk W Yoon; Maria G Liljeroth; Jane V Stiles; Justus E Roos; W Michael Foster; Craig R Rackley; H P McAdams; Bastiaan Driehuys
Journal:  J Appl Physiol (1985)       Date:  2014-07-18

4.  Longitudinal Computed Tomography and Magnetic Resonance Imaging of COPD: Thoracic Imaging Network of Canada (TINCan) Study Objectives.

Authors:  Miranda Kirby; Damien Pike; David G McCormack; Stephen Lam; Harvey O Coxson; Grace Parraga
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

Review 5.  Imaging radiation-induced normal tissue injury.

Authors:  Mike E Robbins; Judy K Brunso-Bechtold; Ann M Peiffer; Christina I Tsien; Janet E Bailey; Lawrence B Marks
Journal:  Radiat Res       Date:  2012-02-21       Impact factor: 2.841

6.  Emphysema quantification in inflation-fixed lungs using low-dose computed tomography and 3He magnetic resonance imaging.

Authors:  David S Gierada; Jason C Woods; Richard E Jacob; Andrew J Bierhals; Cliff K Choong; Seth T Bartel; Yulin V Chang; Nitin A Das; Cheng Hong; Barbara A Lutey; Jon H Ritter; Thomas K Pilgram; Joel D Cooper; G Alexander Patterson; Richard J Battafarano; Bryan F Meyers; Dmitriy A Yablonskiy; Mark S Conradi
Journal:  J Comput Assist Tomogr       Date:  2010 Sep-Oct       Impact factor: 1.826

7.  Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection.

Authors:  Rafael L O'Halloran; James H Holmes; Yu-Chien Wu; Andrew Alexander; Sean B Fain
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

8.  Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Authors:  Francesca Pennati; James D Quirk; Dmitriy A Yablonskiy; Mario Castro; Andrea Aliverti; Jason C Woods
Journal:  Radiology       Date:  2014-06-15       Impact factor: 11.105

9.  Effects of diffusion time on short-range hyperpolarized (3)He diffusivity measurements in emphysema.

Authors:  David S Gierada; Jason C Woods; Andrew J Bierhals; Seth T Bartel; Jon H Ritter; Cliff K Choong; Nitin A Das; Cheng Hong; Thomas K Pilgram; Yulin V Chang; Richard E Jacob; James C Hogg; Richard J Battafarano; Joel D Cooper; Bryan F Meyers; G Alexander Patterson; Dmitriy A Yablonskiy; Mark S Conradi
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

Review 10.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.