Literature DB >> 15906344

Diffusion-weighted MRI of the lung with hyperpolarized helium-3: a study of reproducibility.

Andreas E Morbach1, Klaus K Gast, Jörg Schmiedeskamp, Anja Dahmen, Annette Herweling, Claus P Heussel, Hans-Ulrich Kauczor, Wolfgang G Schreiber.   

Abstract

PURPOSE: To determine the reproducibility of several parameters of the ADC measurement by calculating the scan-to-scan intrasubject variability.
MATERIALS AND METHODS: Measurements were performed using a gradient-echo sequence with a bipolar gradient for diffusion weighting (b=3.89 sec/cm2). Five patients with pulmonary emphysema, and six healthy-lung volunteers were included in the study. Images were acquired after inspiration of 3He during a single inspiratory breath-hold. To assess the reproducibility, the measurement was performed twice (time between measurements=20 minutes) without repositioning the subjects. Analysis was performed on the basis of region-of-interest (ROI) analysis and global lung ADC histograms.
RESULTS: The mean ADC of a ROI varied by 5.1% between two measurements for volunteers and by 6.1% for patients. In the global evaluation, the 75th percentile demonstrated the best reproducibility (2%), while other parameters showed variations up to 12%. Only the variation of the standard deviation (SD) and the measure of homogeneity of the ADC map showed a significant difference between patients and volunteers.
CONCLUSION: Diffusion-weighted imaging (DWI) is a well-reproducible method for assessing the lung microstructure. Copyright (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15906344     DOI: 10.1002/jmri.20300

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  23 in total

1.  How accurately can the parameters from a model of anisotropic 3He gas diffusion in lung acinar airways be estimated? Bayesian view.

Authors:  Alexander L Sukstanskii; G Larry Bretthorst; Yulin V Chang; Mark S Conradi; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2006-10-09       Impact factor: 2.229

2.  In vivo lung morphometry with hyperpolarized 3He diffusion MRI: theoretical background.

Authors:  A L Sukstanskii; D A Yablonskiy
Journal:  J Magn Reson       Date:  2007-11-01       Impact factor: 2.229

3.  Role of collateral paths in long-range diffusion in lungs.

Authors:  Seth-Emil T Bartel; Susan E Haywood; Jason C Woods; Yulin V Chang; Christopher Menard; Dmitriy A Yablonskiy; David S Gierada; Mark S Conradi
Journal:  J Appl Physiol (1985)       Date:  2008-02-21

Review 4.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

5.  In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction.

Authors:  James D Quirk; Yulin V Chang; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

Review 6.  The role of advanced imaging techniques in cystic fibrosis follow-up: is there a place for MRI?

Authors:  Michael Puderbach; Monika Eichinger
Journal:  Pediatr Radiol       Date:  2010-04-30

7.  Longitudinal Computed Tomography and Magnetic Resonance Imaging of COPD: Thoracic Imaging Network of Canada (TINCan) Study Objectives.

Authors:  Miranda Kirby; Damien Pike; David G McCormack; Stephen Lam; Harvey O Coxson; Grace Parraga
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

8.  Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales: comparison with healthy subjects and patients with COPD.

Authors:  Chengbo Wang; Talissa A Altes; John P Mugler; G Wilson Miller; Kai Ruppert; Jaime F Mata; Gordon D Cates; Larry Borish; Eduard E de Lange
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

9.  Effects of diffusion time on short-range hyperpolarized (3)He diffusivity measurements in emphysema.

Authors:  David S Gierada; Jason C Woods; Andrew J Bierhals; Seth T Bartel; Jon H Ritter; Cliff K Choong; Nitin A Das; Cheng Hong; Thomas K Pilgram; Yulin V Chang; Richard E Jacob; James C Hogg; Richard J Battafarano; Joel D Cooper; Bryan F Meyers; G Alexander Patterson; Dmitriy A Yablonskiy; Mark S Conradi
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

Review 10.  New insights on COPD imaging via CT and MRI.

Authors:  N Sverzellati; F Molinari; T Pirronti; L Bonomo; P Spagnolo; M Zompatori
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2007
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.