Literature DB >> 15376770

Compact intra- and extracorporeal oxygenator developments.

Giorgio Cattaneo1, Andreas Strauss, Helmut Reul.   

Abstract

For patients with acute lung failure, mechanical ventilation entails the risk of lung tissue damage due to high oxygen pressure and concentration. Membrane oxygenation for one to two weeks can rest the lungs due to decreased ventilation parameters, representing a potential bridge to recovery, but implies the substantial risks of blood damage, plasma leakage and infection, which often have fatal results for patients. At the Helmholtz Institute in Aachen, two types of membrane oxygenators, which aim to overcome previous limits, are under development. Both present compact designs, reduced surface and priming volumes and easier handling. HEXMO is a miniaturized extracorporeal membrane oxygenator. The integration of a small rotary blood pump into the centre of the oxygenator reduces the amount of tubing and connectors in the system. Blood is convectively warmed by the pump motor housing, thus, the use of a heat-exchanger can be avoided. This compact design reduces surface and priming volume and allows better handling, especially in critical situations. A second development is the intravascular oxygenator HIMOX, which is inserted directly into the vena cava. Priming volume and blood contact surface are reduced, as well as infection risk and control needs for the patient. A new cross-flow fibre configuration is used for improving gas transfer within the limited space inside the vena cava. A microaxial blood pump is integrated into the device for compensating the pressure drop across the fibres and allowing venous return and physiological pressure in the organs proximal to the oxygenator.

Entities:  

Mesh:

Year:  2004        PMID: 15376770     DOI: 10.1191/0267659104pf748oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  5 in total

Review 1.  Artificial lungs: current state and trends of clinical use and research and development.

Authors:  Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

2.  Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

Authors:  R Garrett Jeffries; Brian J Frankowski; Greg W Burgreen; William J Federspiel
Journal:  Artif Organs       Date:  2014-04-22       Impact factor: 3.094

3.  Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.

Authors:  Heide J Eash; Kevin M Mihelc; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2007 May-Jun       Impact factor: 2.872

4.  Estimation Methods for Viscosity, Flow Rate and Pressure from Pump-Motor Assembly Parameters.

Authors:  Martin Elenkov; Paul Ecker; Benjamin Lukitsch; Christoph Janeczek; Michael Harasek; Margit Gföhler
Journal:  Sensors (Basel)       Date:  2020-03-06       Impact factor: 3.576

Review 5.  Toward a Long-Term Artificial Lung.

Authors:  Jutta Arens; Oliver Grottke; Axel Haverich; Lars S Maier; Thomas Schmitz-Rode; Ulrich Steinseifer; H P Wendel; Rolf Rossaint
Journal:  ASAIO J       Date:  2020-08       Impact factor: 3.826

  5 in total