Literature DB >> 2474489

Variations in optical absorption spectra of adult and fetal hemoglobins and its effect on pulse oximetry.

Y Mendelson, J C Kent.   

Abstract

One of the concerns clinicians have relates to the interpretation of noninvasive pulse oximeters in newborns since at birth high levels of fetal hemoglobin (HbF) is present in the blood. Accurate in vivo studies of pulse oximeters in infants with predominantly HbF cannot be easily performed. Therefore, the objective of this in vitro study was to determine whether the presence of high levels of HbF in the blood can significantly affect the accuracy of noninvasive pulse oximeters. It is evident from our results that there is no perceptible difference in the 650-1000 nm wavelength region, which is commonly used in pulse oximetry, between the optical absorption spectra of hemolyzed whole adult and fetal blood. Our observations are in good agreement with in vivo studies published by other investigators showing considerable correlations between SpO2 measured by a pulse oximeter and SaO2 values analyzed in vitro by an IL 282 CO-Oximeter.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2474489     DOI: 10.1109/10.30810

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

Review 1.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

Review 2.  Uses and abuses of pulse oximetry.

Authors:  J T Moyle
Journal:  Arch Dis Child       Date:  1996-01       Impact factor: 3.791

3.  Pulse oximetry: theoretical and experimental models.

Authors:  J P de Kock; L Tarassenko
Journal:  Med Biol Eng Comput       Date:  1993-05       Impact factor: 2.602

4.  Non-contact measurement of oxygen saturation with an RGB camera.

Authors:  Alessandro R Guazzi; Mauricio Villarroel; João Jorge; Jonathan Daly; Matthew C Frise; Peter A Robbins; Lionel Tarassenko
Journal:  Biomed Opt Express       Date:  2015-08-11       Impact factor: 3.732

5.  Two-photon excited hemoglobin fluorescence.

Authors:  Wei Zheng; Dong Li; Yan Zeng; Yi Luo; Jianan Y Qu
Journal:  Biomed Opt Express       Date:  2010-12-06       Impact factor: 3.732

Review 6.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08

7.  Measuring hemoglobin spectra: searching for carbamino-hemoglobin.

Authors:  Emmanuel Dervieux; Quentin Bodinier; Wilfried Uhring; Michaël Théron
Journal:  J Biomed Opt       Date:  2020-10       Impact factor: 3.170

  7 in total