Pulse oximetry: theoretical and experimental models.

J P de Kock1, L Tarassenko.   

Abstract

In the paper a pulse oximetry model is developed using an approach which combines both theoretical and empirical modelling. The optical properties of whole blood are measured as a function of cuvette depth by transmission spectrophotometry using red (660 nm) and infra-red (950 nm) light-emitting diodes as light sources. Twersky's theoretical model gives the best fit to the experimental data. A simple theoretical model which takes into account the nonlinear relationship between optical density and cuvette depth is then used to obtain an expression for the R:IR ratio, which relates the measurement of transmission at the two wavelengths. The R:IR ratio is found to be more or less independent of cuvette depth (SD = 0.14 at 100 per cent SaO2). To validate the predictions of the theoretical model, the results of a previous experiment in which the relationship between SaO2 and the R:IR ratio was recorded using a flexible cuvette are used. The experimental values are found to lie within one standard deviation from the theoretical curve relating SaO2 and the R:IR ratio. It is argued that a reasonably accurate model for pulse oximetry which is based on whole blood and not haemoglobin solutions has been developed.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8412383     DOI: 10.1007/bf02458049

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  20 in total

1.  STUDIES ON THE LIGHT TRANSMISSION OF NONHEMOLYZED WHOLE BLOOD. DETERMINATION OF OXYGEN SATURATION.

Authors:  N M ANDERSON; P SEKELJ
Journal:  J Lab Clin Med       Date:  1965-01

2.  Multiple scattering of waves and optical phenomena.

Authors:  V TWERSKY
Journal:  J Opt Soc Am       Date:  1962-02

3.  In vitro investigation of the factors affecting pulse oximetry.

Authors:  J P de Kock; L Tarassenko
Journal:  J Biomed Eng       Date:  1991-01

Review 4.  Pulse oximetry: analysis of theory, technology, and practice.

Authors:  M W Wukitsch; M T Petterson; D R Tobler; J A Pologe
Journal:  J Clin Monit       Date:  1988-10

5.  Variations in optical absorption spectra of adult and fetal hemoglobins and its effect on pulse oximetry.

Authors:  Y Mendelson; J C Kent
Journal:  IEEE Trans Biomed Eng       Date:  1989-08       Impact factor: 4.538

6.  A Monte Carlo model for the absorption and flux distributions of light in tissue.

Authors:  B C Wilson; G Adam
Journal:  Med Phys       Date:  1983 Nov-Dec       Impact factor: 4.071

7.  Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter.

Authors:  Y Shimada; I Yoshiya; N Oka; K Hamaguri
Journal:  Med Biol Eng Comput       Date:  1984-09       Impact factor: 2.602

8.  The optics of human skin.

Authors:  R R Anderson; J A Parrish
Journal:  J Invest Dermatol       Date:  1981-07       Impact factor: 8.551

9.  A noninvasive tissue reflectance oximeter. An instrument for measurement of tissue hemoglobin oxygen saturation in vivo.

Authors:  S Takatani; P W Cheung; E A Ernst
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

10.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

View more
  3 in total

1.  Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry.

Authors:  Jeonghyun Kim; Philipp Gutruf; Antonio M Chiarelli; Seung Yun Heo; Kyoungyeon Cho; Zhaoqian Xie; Anthony Banks; Seungyoung Han; Kyung-In Jang; Jung Woo Lee; Kyu-Tae Lee; Xue Feng; Yonggang Huang; Monica Fabiani; Gabriele Gratton; Ungyu Paik; John A Rogers
Journal:  Adv Funct Mater       Date:  2016-11-25       Impact factor: 18.808

2.  A prototype device for standardized calibration of pulse oximeters.

Authors:  C Hornberger; P Knoop; W Nahm; H Matz; E Konecny; H Gehring; R Bonk; H Frankenberger; G Meyfroidt; P Wouters; J Gil-Rodriguez; L Ponz; K Benekos; J Valais; J Avgerinos; A Karoutis; A Ikiades; S Weininger
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Reflectance-Based Organic Pulse Meter Sensor for Wireless Monitoring of Photoplethysmogram Signal.

Authors:  Fahed Elsamnah; Anubha Bilgaiyan; Muhamad Affiq; Chang-Hoon Shim; Hiroshi Ishidai; Reiji Hattori
Journal:  Biosensors (Basel)       Date:  2019-07-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.