Literature DB >> 24744126

Intraoperative detection and localization of cylindrical implants in cone-beam CT image data.

Joseph Görres1, Michael Brehler2, Jochen Franke3, Karl Barth4, Sven Y Vetter3, Andrés Córdova5, Paul A Grützner3, Hans-Peter Meinzer2, Ivo Wolf6, Diana Nabers2.   

Abstract

PURPOSE: Orthopedic fractures are often fixed using metal implants. The correct positioning of cylindrical implants such as surgical screws, rods and guide wires is highly important. Intraoperative 3D imaging is often used to ensure proper implant placement. However, 3D image interaction is time-consuming and requires experience. We developed an automatic method that simplifies and accelerates location assessment of cylindrical implants in 3D images.
METHODS: Our approach is composed of three major steps. At first, cylindrical characteristics are detected by analyzing image gradients in small image regions. Next, these characteristics are grouped in a cluster analysis. The clusters represent cylindrical implants and are used to initialize a cylinder-to-image registration. Finally, the two end points are optimized regarding image contrast along the cylinder axis.
RESULTS: A total of 67 images containing 420 cylindrical implants were used for testing. Different anatomical regions (calcaneus, spine) and various image sources (two mobile devices, three reconstruction methods) were investigated. Depending on the evaluation set, the detection performance was between 91.7 and 96.1% true- positive rate with a false-positive rate between 2.0 and 3.2%. The end point distance errors ranged from [Formula: see text] to [Formula: see text] mm and the orientation errors from [Formula: see text] to [Formula: see text] degrees. The average computation time was less than 5 seconds.
CONCLUSIONS: An automatic method was developed and tested that obviates the need for 3D image interaction during intraoperative assessment of cylindrical orthopedic implants. The required time for working with the viewing software of cone-beam CT device is drastically reduced and leads to a shorter time under anesthesia for the patient.

Entities:  

Keywords:  Calcaneus; Clustering; Cylinder detection; Internal fixation; Intraoperative Imaging; PCA; RANSAC; Segmentation; Spine

Mesh:

Year:  2014        PMID: 24744126     DOI: 10.1007/s11548-014-0998-8

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  12 in total

Review 1.  Displaced intra-articular fractures of the calcaneus.

Authors:  R Sanders
Journal:  J Bone Joint Surg Am       Date:  2000-02       Impact factor: 5.284

2.  Parametric estimate of intensity inhomogeneities applied to MRI.

Authors:  M Styner; C Brechbühler; G Székely; G Gerig
Journal:  IEEE Trans Med Imaging       Date:  2000-03       Impact factor: 10.048

3.  Frequency split metal artifact reduction (FSMAR) in computed tomography.

Authors:  Esther Meyer; Rainer Raupach; Michael Lell; Bernhard Schmidt; Marc Kachelrieß
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  [The clinical use of the ISO-C(3D) imaging system in calcaneus fracture surgery].

Authors:  A Rübberdt; R Feil; D Stengel; N Spranger; S Mutze; M Wich; A Ekkernkamp
Journal:  Unfallchirurg       Date:  2006-02       Impact factor: 1.000

5.  Intraoperative 3-dimensional imaging in foot and ankle trauma-experience with a second-generation device (ARCADIS-3D).

Authors:  Martinus Richter; Stefan Zech
Journal:  J Orthop Trauma       Date:  2009-03       Impact factor: 2.512

6.  The Medical Imaging Interaction Toolkit: challenges and advances : 10 years of open-source development.

Authors:  Marco Nolden; Sascha Zelzer; Alexander Seitel; Diana Wald; Michael Müller; Alfred M Franz; Daniel Maleike; Markus Fangerau; Matthias Baumhauer; Lena Maier-Hein; Klaus H Maier-Hein; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-04-16       Impact factor: 2.924

7.  Intraoperative 3D imaging in calcaneal fracture care-clinical implications and decision making.

Authors:  Jens Geerling; Daniel Kendoff; Musa Citak; Stefan Zech; Michael J Gardner; Tobias Hüfner; Christian Krettek; Martinus Richter
Journal:  J Trauma       Date:  2009-03

8.  Intraoperative 3D imaging: value and consequences in 248 cases.

Authors:  Daniel Kendoff; Musa Citak; Michael J Gardner; Timo Stübig; Christian Krettek; Tobias Hüfner
Journal:  J Trauma       Date:  2009-01

9.  [Intraoperative 3-dimensional imaging - beneficial or necessary?].

Authors:  J Franke; J von Recum; K Wendl; P A Grützner
Journal:  Unfallchirurg       Date:  2013-02       Impact factor: 1.000

10.  Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy.

Authors:  Wu Qiu; Ming Yuchi; Mingyue Ding; David Tessier; Aaron Fenster
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

View more
  8 in total

1.  Fully automatic catheter segmentation in MRI with 3D convolutional neural networks: application to MRI-guided gynecologic brachytherapy.

Authors:  Paolo Zaffino; Guillaume Pernelle; Andre Mastmeyer; Alireza Mehrtash; Hongtao Zhang; Ron Kikinis; Tina Kapur; Maria Francesca Spadea
Journal:  Phys Med Biol       Date:  2019-08-14       Impact factor: 3.609

2.  Articular surface segmentation using active shape models for intraoperative implant assessment.

Authors:  Joseph Görres; Michael Brehler; Jochen Franke; Sven Y Vetter; Paul A Grützner; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-19       Impact factor: 2.924

3.  Automatic multi-catheter detection using deeply supervised convolutional neural network in MRI-guided HDR prostate brachytherapy.

Authors:  Xianjin Dai; Yang Lei; Yupei Zhang; Richard L J Qiu; Tonghe Wang; Sean A Dresser; Walter J Curran; Pretesh Patel; Tian Liu; Xiaofeng Yang
Journal:  Med Phys       Date:  2020-06-15       Impact factor: 4.071

4.  Intra-operative assessment of fractured articular surfaces in cone beam CT image data.

Authors:  Michael Brehler; Joseph Görres; Sven Y Vetter; Jochen Franke; Paul A Grützner; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

5.  Automatic Needle Segmentation and Localization in MRI With 3-D Convolutional Neural Networks: Application to MRI-Targeted Prostate Biopsy.

Authors:  Alireza Mehrtash; Mohsen Ghafoorian; Guillaume Pernelle; Alireza Ziaei; Friso G Heslinga; Kemal Tuncali; Andriy Fedorov; Ron Kikinis; Clare M Tempany; William M Wells; Purang Abolmaesumi; Tina Kapur
Journal:  IEEE Trans Med Imaging       Date:  2018-10-18       Impact factor: 10.048

6.  Spinal pedicle screw planning using deformable atlas registration.

Authors:  J Goerres; A Uneri; T De Silva; M Ketcha; S Reaungamornrat; M Jacobson; S Vogt; G Kleinszig; G Osgood; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-02-08       Impact factor: 4.174

7.  Statistical, Morphometric, Anatomical Shape Model (Atlas) of Calcaneus.

Authors:  Aleksandra U Melinska; Patryk Romaszkiewicz; Justyna Wagel; Marek Sasiadek; D Robert Iskander
Journal:  PLoS One       Date:  2015-08-13       Impact factor: 3.240

8.  Automated fiducial marker detection and localization in volumetric computed tomography images: a three-step hybrid approach with deep learning.

Authors:  Milovan Regodić; Zoltan Bardosi; Wolfgang Freysinger
Journal:  J Med Imaging (Bellingham)       Date:  2021-04-28
  8 in total