BACKGROUND: Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24708734 PMCID: PMC3986444 DOI: 10.1186/1471-2334-14-187
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Figure 1Photograph of the PPX-UV device.
Figure 2Schematic of two patient rooms showing positioning of PPX-UV unit.
Methicillin-resistant and bacterial heterotrophic plate counts before and after disinfection per room for five high-touch surfaces total
| | | ||
|---|---|---|---|
| | | | |
| 255.0; 278.0 (132-304) | 60.4; 31.0 (15-70) | 76.3% | |
| 449.0; 364.5 (332-530) | 8.4; 4.0 (1-10) | 98.1% | |
| | | ||
| | | | |
| 127.3; 28.5 (8-143) | 11.3; 1.0 (0-4) | 91.1% | |
| 108.2; 123.0 (14-183) | 0.7; 0.0 (0-1) | 99.4% | |
HPC: Bacterial heterotrophic plate counts.
MRSA: Methicillin-resistant Staphylococcus aureus.
PPX-UV: Portable pulsed xenon ultraviolet.
Estimated effect of cleaning protocol on colony counts: manual cleaning vs portable pulsed ultraviolet machine cleaning (N = 20 rooms)
| | | | | | | |
| Baseline count | 0.004 | <0.0-0.001 | -- | | 3.24 | 0.07 |
| Manual cleaning | 2.0 | 0.2-3.7 | 7.2 | 1.3-41.4 | 4.91 | 0.03 |
| | | -- | | | | |
| Baseline count | 0.002 | <0.0-0.01 | | | 1.49 | 0.22 |
| Manual cleaning | 2.6 | 1.3-3.8 | 12.9 | 3.5-47.8 | 14.7 | <.01 |
Total positive plates & colony counts per site by bacterial heterotrophic colony counts and methicillin-resistant before and after manual and UV light disinfection for 5 high touch surfaces
| | ||||||||
|---|---|---|---|---|---|---|---|---|
| Bed rail | 10/10 (774) | 10/10 (30) | 10/10 (1079) | 0/10 (0) | 8/10 (308) | 0/10 (0) | 8/10 (188) | 0/10 (0) |
| Call button | 10/10 (494) | 6/10 (64) | 10/10 (1121) | 3/10 (54) | 9/10 (89) | 1/9 (1) | 8/10 (286) | 1/10 (1) |
| Tray table | 10/10 (311) | 8/10 (21) | 10/10 (293) | 1/10 (4) | 9/10 (48) | 1/10 (1) | 5/10 (10) | 1/10 (1) |
| Bathroom handrail | 10/10 (392) | 10/10 (91) | 10/10 (988) | 5/10 (20) | 8/10 (269) | 3/10 (86) | 9/10 (265) | 2/10 (5) |
| Toilet seat | 10/10 (579) | 7/10 (398) | 10/10 (1009) | 2/10 (6) | 9/10 (559) | 3/10 (25) | 8/10 (333) | 0/10 (0) |
| Total | 50/50 (2550) | 41/50 (604) | 50/50 (4490) | 11/50 (84) | 43/50 (1273) | 8/49 (113) | 38/50 (1082) | 4/50 (7) |
HPC: Bacterial heterotrophic plate counts.
MRSA: Methicillin-resistant Staphylococcus aureus.
PPX-UV: Portable pulsed xenon Ultraviolet.