Ambulance disinfection using Ultraviolet Germicidal Irradiation (UVGI): Effects of fixture location and surface reflectivity.

William G Lindsley1, Tia L McClelland2, Dylan T Neu3, Stephen B Martin2, Kenneth R Mead3, Robert E Thewlis1, John D Noti1.   

Abstract

Ambulances are frequently contaminated with infectious microorganisms shed by patients during transport that can be transferred to subsequent patients and emergency medical service workers. Manual decontamination is tedious and time-consuming, and persistent contamination is common even after cleaning. Ultraviolet germicidal irradiation (UVGI) has been proposed as a terminal disinfection method for ambulance patient compartments. However, no published studies have tested the use of UVGI in ambulances. The objectives of this study were to investigate the efficacy of a UVGI system in an ambulance patient compartment and to examine the impact of UVGI fixture position and the UV reflectivity of interior surfaces on the time required for disinfection. A UVGI fixture was placed in the front, middle, or back of an ambulance patient compartment, and the UV irradiance was measured at 49 locations. Aluminum sheets and UV-reflective paint were added to examine the effects of increasing surface reflectivity on disinfection time. Disinfection tests were conducted using Bacillus subtilis spores as a surrogate for pathogens. Our results showed that the UV irradiance varied considerably depending upon the surface location. For example, with the UVGI fixture in the back position and without the addition of UV-reflective surfaces, the most irradiated location received a dose of UVGI sufficient for disinfection in 16 s, but the least irradiated location required 15 hr. Because the overall time required to disinfect all of the interior surfaces is determined by the time required to disinfect the surfaces receiving the lowest irradiation levels, the patient compartment disinfection times for different UVGI configurations ranged from 16.5 hr to 59 min depending upon the UVGI fixture position and the interior surface reflectivity. These results indicate that UVGI systems can reduce microbial surface contamination in ambulance compartments, but the systems must be rigorously validated before deployment. Optimizing the UVGI fixture position and increasing the UV reflectivity of the interior surfaces can substantially improve the performance of a UVGI system and reduce the time required for disinfection.

Entities:  

Keywords:  Ambulance; decontamination; emergency medical services; health care-associated infection; infection control

Mesh:

Year:  2018        PMID: 29059039      PMCID: PMC6379899          DOI: 10.1080/15459624.2017.1376067

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  18 in total

1.  Detection and analysis of Staphylococcus aureus isolates found in ambulances in the Chicago metropolitan area.

Authors:  James V Rago; Lieutenant Keith Buhs; Viktorija Makarovaite; Esha Patel; Melissa Pomeroy; Christian Yasmine
Journal:  Am J Infect Control       Date:  2012-04       Impact factor: 2.918

Review 2.  Guideline for the prevention and control of norovirus gastroenteritis outbreaks in healthcare settings.

Authors:  Taranisia MacCannell; Craig A Umscheid; Rajender K Agarwal; Ingi Lee; Gretchen Kuntz; Kurt B Stevenson
Journal:  Infect Control Hosp Epidemiol       Date:  2011-09-01       Impact factor: 3.254

3.  Rapid hospital room decontamination using ultraviolet (UV) light with a nanostructured UV-reflective wall coating.

Authors:  William A Rutala; Maria F Gergen; Brian M Tande; David J Weber
Journal:  Infect Control Hosp Epidemiol       Date:  2013-05       Impact factor: 3.254

4.  UV-C Light Disinfection of Carbapenem-Resistant Enterobacteriaceae from High-Touch Surfaces in a Patient Room and Bathroom.

Authors:  Clare Rock; Melanie S Curless; Elaine Nowakowski; Tracy Ross; Kathryn A Carson; Polly Trexler; Karen Carroll; Lisa L Maragakis
Journal:  Infect Control Hosp Epidemiol       Date:  2016-05-13       Impact factor: 3.254

5.  Impact of Ultraviolet Germicidal Irradiation for No-Touch Terminal Room Disinfection on Clostridium difficile Infection Incidence Among Hematology-Oncology Patients.

Authors:  David A Pegues; Jennifer Han; Cheryl Gilmar; Brooke McDonnell; Steven Gaynes
Journal:  Infect Control Hosp Epidemiol       Date:  2016-10-06       Impact factor: 3.254

6.  Enhanced terminal room disinfection and acquisition and infection caused by multidrug-resistant organisms and Clostridium difficile (the Benefits of Enhanced Terminal Room Disinfection study): a cluster-randomised, multicentre, crossover study.

Authors:  Deverick J Anderson; Luke F Chen; David J Weber; Rebekah W Moehring; Sarah S Lewis; Patricia F Triplett; Michael Blocker; Paul Becherer; J Conrad Schwab; Lauren P Knelson; Yuliya Lokhnygina; William A Rutala; Hajime Kanamori; Maria F Gergen; Daniel J Sexton
Journal:  Lancet       Date:  2017-01-17       Impact factor: 79.321

7.  Considerations for safe EMS transport of patients infected with Ebola virus.

Authors:  John J Lowe; Katelyn C Jelden; Paul J Schenarts; Lloyd E Rupp; Kingdon J Hawes; Benjamin M Tysor; Raymond G Swansiger; Shelly S Schwedhelm; Philip W Smith; Shawn G Gibbs
Journal:  Prehosp Emerg Care       Date:  2014-11-07       Impact factor: 3.077

8.  Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device.

Authors:  Deverick J Anderson; Maria F Gergen; Emily Smathers; Daniel J Sexton; Luke F Chen; David J Weber; William A Rutala
Journal:  Infect Control Hosp Epidemiol       Date:  2013-05       Impact factor: 3.254

9.  Spread of infectious microbes during emergency medical response.

Authors:  Melissa K Valdez; Jonathan D Sexton; Eric A Lutz; Kelly A Reynolds
Journal:  Am J Infect Control       Date:  2015-06       Impact factor: 2.918

Review 10.  Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: Focus on clinical trials.

Authors:  David J Weber; William A Rutala; Deverick J Anderson; Luke F Chen; Emily E Sickbert-Bennett; John M Boyce
Journal:  Am J Infect Control       Date:  2016-05-02       Impact factor: 2.918

View more
  6 in total

Review 1.  Transmittance and Survival of SARS-CoV-2 in Global Trade: The Role of Supply Chain and Packaging.

Authors:  Marko Hakovirta; Janetta Hakovirta
Journal:  J Packag Technol Res       Date:  2020-09-29

2.  Ultraviolet disinfection robots to improve hospital cleaning: Real promise or just a gimmick?

Authors:  Magda Diab-El Schahawi; Walter Zingg; Margreet Vos; Hilary Humphreys; Lorena Lopez-Cerero; Astrid Fueszl; Jean Ralph Zahar; Elisabeth Presterl
Journal:  Antimicrob Resist Infect Control       Date:  2021-02-12       Impact factor: 4.887

3.  Exploring the Applicability of Robot-Assisted UV Disinfection in Radiology.

Authors:  Conor McGinn; Robert Scott; Niamh Donnelly; Kim L Roberts; Marina Bogue; Christine Kiernan; Michael Beckett
Journal:  Front Robot AI       Date:  2021-01-06

4.  Comparing and optimizing ultraviolet germicidal irradiation systems use for patient room terminal disinfection: an exploratory study using radiometry and commercial test cards.

Authors:  Vincent Masse; Michael J Hartley; Michael B Edmond; Daniel J Diekema
Journal:  Antimicrob Resist Infect Control       Date:  2018-02-22       Impact factor: 4.887

5.  Prehospital infection control and prevention in Denmark: a cross-sectional study on guideline adherence and microbial contamination of surfaces.

Authors:  Heidi Storm Vikke; Matthias Giebner; Hans Jørn Kolmos
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2018-09-05       Impact factor: 2.953

6.  The use of a UV-C disinfection robot in the routine cleaning process: a field study in an Academic hospital.

Authors:  Füszl Astrid; Zatorska Beata; Ebner Julia; Presterl Elisabeth; Diab-Elschahawi Magda
Journal:  Antimicrob Resist Infect Control       Date:  2021-05-29       Impact factor: 4.887

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.