Literature DB >> 24705875

Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Mambo Moyo1, Jonathan O Okonkwo, Nana M Agyei.   

Abstract

The preparation and application of a practical electrochemical sensor for environmental monitoring and assessment of heavy metal ions in samples is a subject of considerable interest. In this paper, a carbon paste electrode modified with maize tassel for the determination of Cu(II) has been proposed. Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were used to study morphology and identify the functional groups on the modified electrode, respectively. First, Cu(II) was adsorbed on the carbon paste electrode surface at open circuit and voltammetric techniques were used to investigate the electrochemical performances of the sensor. The electrochemical sensor showed an excellent electrocatalytic activity towards Cu(II) at pH 5.0 and by increasing the amount of maize tassel biomass, a maximum response at 1:2.5 (maize tassel:carbon paste; w/w) was obtained. The electrocatalytic redox current of Cu(II) showed a linear response in the range (1.23 μM to 0.4 mM) with the correlation coefficient of 0.9980. The limit of detection and current-concentration sensitivity were calculated to be 0.13 (±0.01) μM and 0.012 (±0.001) μA/μM, respectively. The sensor gave good recovery of Cu(II) in the range from 96.0 to 98.0 % when applied to water samples.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24705875     DOI: 10.1007/s10661-014-3739-0

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  20 in total

1.  Amperometric measurement of copper ions with a deputy substrate using a novel Saccharomyces cerevisiae sensor.

Authors:  M Lehmann; K Riedel; K Adler; G Kunze
Journal:  Biosens Bioelectron       Date:  2000-06       Impact factor: 10.618

Review 2.  Biosensors for heavy metals.

Authors:  Neelam Verma; Minni Singh
Journal:  Biometals       Date:  2005-04       Impact factor: 2.949

3.  Removal of nickel (II) from aqueous solutions using marine macroalgae as the sorbing biomass.

Authors:  S Kalyani; P Srinivasa Rao; A Krishnaiah
Journal:  Chemosphere       Date:  2004-12       Impact factor: 7.086

4.  Bioaccumulation and measurement of copper at an alga-modified carbon paste electrode.

Authors:  J Gardea-Torresdey; D Darnall; J Wang
Journal:  Anal Chem       Date:  1988-01-01       Impact factor: 6.986

5.  Characterization of a carbon paste electrode modified with tripolyphosphate-modified kaolinite clay for the detection of lead.

Authors:  Yoleydis Gómez; Lenys Fernández; Carlos Borrás; Jorge Mostany; Benjamín Scharifker
Journal:  Talanta       Date:  2011-06-15       Impact factor: 6.057

6.  Spectrophotometric determination of trace copper in water samples with thiomichlersketone.

Authors:  Dayou Fu; Dong Yuan
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2006-07-21       Impact factor: 4.098

7.  Carbon paste electrodes modified with Bi(2)O(3) as sensors for the determination of Cd and Pb.

Authors:  Rasa Pauliukaite; Radovan Metelka; Ivan Svancara; Agnieszka Królicka; Andrzej Bobrowski; Karel Vytras; Eugenijus Norkus; Kurt Kalcher
Journal:  Anal Bioanal Chem       Date:  2002-10-24       Impact factor: 4.142

8.  Simultaneous determination of copper and iron in automotive gasoline by X-ray fluorescence after pre-concentration on cellulose paper.

Authors:  Leonardo S G Teixeira; Rodrigo B S Rocha; Eledir V Sobrinho; Paulo R B Guimarães; Luiz A M Pontes; Josanaide S R Teixeira
Journal:  Talanta       Date:  2007-01-09       Impact factor: 6.057

9.  Application of maize tassel for the removal of Pb, Se, Sr, U and V from borehole water contaminated with mine wastewater in the presence of alkaline metals.

Authors:  Caliphs M Zvinowanda; Jonathan O Okonkwo; Mahlatse M Sekhula; Nana M Agyei; Rotimi Sadiku
Journal:  J Hazard Mater       Date:  2008-09-10       Impact factor: 10.588

10.  Detection of heavy metal toxicity using cardiac cell-based biosensor.

Authors:  Qingjun Liu; Hua Cai; Ying Xu; Lidan Xiao; Mo Yang; Ping Wang
Journal:  Biosens Bioelectron       Date:  2007-03-12       Impact factor: 10.618

View more
  3 in total

1.  Construction of a nanostructure-based electrochemical sensor for voltammetric determination of bisphenol A.

Authors:  Hadi Beitollahi; Somayeh Tajik
Journal:  Environ Monit Assess       Date:  2015-04-16       Impact factor: 2.513

2.  Electrochemical determination of hydrazine using a ZrO2 nanoparticles-modified carbon paste electrode.

Authors:  Sayed Zia Mohammadi; Hadi Beitollahi; Elina Bani Asadi
Journal:  Environ Monit Assess       Date:  2015-02-19       Impact factor: 2.513

3.  High Sensitive Sensor Fabricated by Reduced Graphene Oxide/Polyvinyl Butyral Nanofibers for Detecting Cu (II) in Water.

Authors:  Rui Ding; Zhimin Luo; Xiuling Ma; Xiaoping Fan; Liqun Xue; Xiuzhu Lin; Sheng Chen
Journal:  Int J Anal Chem       Date:  2015-01-28       Impact factor: 1.885

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.