Literature DB >> 21807195

Characterization of a carbon paste electrode modified with tripolyphosphate-modified kaolinite clay for the detection of lead.

Yoleydis Gómez1, Lenys Fernández, Carlos Borrás, Jorge Mostany, Benjamín Scharifker.   

Abstract

We report about the use of carbon paste electrode modified with kaolinite for analytical detection of trace lead(II) in domestic water by differential pulse voltammetry. Kaolinite clay was modified with tripolyphosphate (TPP) by impregnation method. The results show that TPP in kaolinite clay plays an important role in the accumulation process of Pb(II) on the modified electrode surface. The electroanalytical procedure for determination of Pb(II) comprised two steps: chemical accumulation of the analyte under open-circuit conditions, followed by electrochemical detection of the pre-concentrated species using differential pulse voltammetry. The analytical performance of this system has been explored by studying the effects of preconcentration time, carbon paste composition, pH, supporting electrolyte concentration, as well as interferences due to other ions. The calculated detection limit based on the variability of a blank solution (3s(b) criterion) for 10 measurements was 8.4×10(-8) mol L(-1), and the sensitivity determined from the slope of the calibration graph was 0.910 mol L(-1). The reproducibility (RSD) for five replicate measurements at 1.0 mg L(-1) lead level was 1.6%. The results indicate that this electrode is sensitive and effective for the determination of Pb(2+).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21807195     DOI: 10.1016/j.talanta.2011.06.014

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Palygorskite modified with N-doped carbon for sensitive determination of lead(II) by differential pulse anodic stripping voltammetry.

Authors:  Peng Yan; Shilin Zhang; Cunzhong Zhang; Zishuo Liu; Aidong Tang
Journal:  Mikrochim Acta       Date:  2019-10-21       Impact factor: 5.833

2.  Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Environ Monit Assess       Date:  2014-04-06       Impact factor: 2.513

3.  Effects of modified fly ash doped carbon paste electrodes and metal film electrodes on the determination of trace cadmium(ii) by anodic stripping voltammetry.

Authors:  Jinying Hou; Yuping Fan; Xiaomin Ma; Xianshu Dong; Suling Yao
Journal:  RSC Adv       Date:  2021-05-10       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.