Literature DB >> 12458435

Carbon paste electrodes modified with Bi(2)O(3) as sensors for the determination of Cd and Pb.

Rasa Pauliukaite1, Radovan Metelka, Ivan Svancara, Agnieszka Królicka, Andrzej Bobrowski, Karel Vytras, Eugenijus Norkus, Kurt Kalcher.   

Abstract

Carbon paste electrodes bulk-modified with Bi(2)O(3)were used for the determination of Cd(II) and Pb(II). The best composition was 1% (wt%) Bi(2)O(3) in the paste. The measurements were made by differential pulse voltammetry in the potential range from -1.2 V to -0.3 V. The peak potential of the reoxidation of Cd is -0.85 V, and of Pb -0.60 V vs. SCE. The lowest concentration that could be determined was 5 microg L(-1) of both metals (preconcentration time 240 s), the relative standard deviation was 3.5%-5.0% (four determinations). The correlation coefficient ( r(2)) of the calibration curves was 0.9966 (for Cd) and 0.9971 (for Pb). The Bi(2)O(3)-modified electrode could be used for the analysis of drinking water, mineral water and urine.

Entities:  

Year:  2002        PMID: 12458435     DOI: 10.1007/s00216-002-1569-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Environ Monit Assess       Date:  2014-04-06       Impact factor: 2.513

2.  Bismuth film electrode and chloranilic acid as a new alternative for simple, fast and sensitive Ge(iv) quantification by adsorptive stripping voltammetry.

Authors:  Malgorzata Grabarczyk; Marzena Adamczyk
Journal:  RSC Adv       Date:  2018-04-23       Impact factor: 4.036

3.  Analytical Performance of Clay Paste Electrode and Graphene Paste Electrode-Comparative Study.

Authors:  Ewelina Skowron; Kaja Spilarewicz-Stanek; Dariusz Guziejewski; Kamila Koszelska; Radovan Metelka; Sylwia Smarzewska
Journal:  Molecules       Date:  2022-03-22       Impact factor: 4.411

4.  An Efficient Voltammetric Sensor Based on Graphene Oxide-Decorated Binary Transition Metal Oxides Bi2O3/MnO2 for Trace Determination of Lead Ions.

Authors:  Guangli Li; Xiaoman Qi; Yang Xiao; Yuchi Zhao; Kanghua Li; Yonghui Xia; Xuan Wan; Jingtao Wu; Chun Yang
Journal:  Nanomaterials (Basel)       Date:  2022-09-23       Impact factor: 5.719

5.  Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE).

Authors:  Nahid Gharib Naseri; Sara J Baldock; Anastasios Economou; Nicholas J Goddard; Peter R Fielden
Journal:  Anal Bioanal Chem       Date:  2008-03-20       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.