Literature DB >> 19071727

Simultaneous determination of copper and iron in automotive gasoline by X-ray fluorescence after pre-concentration on cellulose paper.

Leonardo S G Teixeira1, Rodrigo B S Rocha, Eledir V Sobrinho, Paulo R B Guimarães, Luiz A M Pontes, Josanaide S R Teixeira.   

Abstract

This paper proposes an alternative analytical method using energy dispersive X-ray fluorescence (EDXRF) to determine Fe and Cu in gasoline samples. In the proposed procedure, samples were distilled and the distillation residues were spotted on cellulose paper disk to form a uniform thin film and to produce a homogeneous and reproducible interface to the XRF instrument. The disks were dried at 60 degrees C for 20min and copper and iron were determined directly in the solid phase at 6.40 and 8.04keV, respectively. The calibration curves showed linear response in the 20-800mugL(-1) concentration range of each metal. The precisions (repeatability) calculated from 15 consecutive measurements and defined as the coefficient of variation of solutions containing 100mugL(-1) of Fe and Cu were 7.8 and 8.1%, respectively. The limits of detection (LOD), defined as the analyte concentration that gives a response equivalent to three times the standard deviation of the blank (n=10), were found to be 10 and 15mugL(-1) for Fe and Cu, respectively. The proposed method was applied to copper and iron determination in gasoline samples collected from different gas stations.

Entities:  

Year:  2007        PMID: 19071727     DOI: 10.1016/j.talanta.2006.12.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Macroemulsion-based dispersive magnetic solid phase extraction for preconcentration and determination of copper(II) in gasoline.

Authors:  Francisco Antônio S Cunha; Danilo Tadeu S Ferreira; Willy C R Andrade; Julys Pablo A Fernandes; Wellington S Lyra; Amália G G Pessoa; Mario Cesar Ugulino de Araujo
Journal:  Mikrochim Acta       Date:  2018-01-10       Impact factor: 5.833

2.  Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Environ Monit Assess       Date:  2014-04-06       Impact factor: 2.513

3.  Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals.

Authors:  Suw Young Ly; Dae Hong Kim; Ga Eun Lee
Journal:  Toxicol Res       Date:  2013-09