Literature DB >> 24700078

128-Slice dual source coronary CTA: defining optimal arterial enhancement levels.

Ashkan A Malayeri1, Stefan L Zimmerman, Spencer T Lake, Elliot K Fishman, Pamela T Johnson.   

Abstract

This study aims to correlate coronary artery enhancement levels with quality of vessel visualization and calcified plaque visualization using a 128-slice dual-source CT (DSCT) scanner. Coronary CT angiography exams from 52 patients, mean age of 55 years (range, 22-90) and mean weight of 184 lbs (range, 120-320 lbs), were reviewed retrospectively. Contrast infusion rates ranged from 4.5 to 7 mL/s (mean, 5.8 mL/s). Postcontrast density of the largest calcified plaque and postcontrast density of the left main (LM) and right coronary arteries (RCA) were recorded. Enhancement quality was graded as 1=suboptimal, 2=adequate for diagnosis, and 3=excellent. Pre- and postcontrast acquisitions were compared for calcified plaque conspicuity. The largest calcified plaque density was a mean of 862 HU (range, 376 to 1,384 HU) on the postcontrast scan. The mean LM and RCA coronary artery enhancement levels for studies of excellent enhancement quality (N=43) were 468 and 457 HU, respectively, higher than mean enhancement levels of 320 and 322 HU for adequate enhancement quality (N=8) (p<0.0001 and 0.009). One study was graded as a nondiagnostic enhancement quality. Twenty-five subjects had calcified plaque, 3/8 with adequate and 22/43 with excellent enhancement quality. At least one calcified plaque measuring <2 mm was isodense to contrast enhancement on axial images in 5/25; all five were in the highest enhancement quality group. High coronary artery enhancement quality using 128-DSCT is associated with mean proximal coronary artery enhancement levels over 400 HU. High levels of enhancement may obscure small, calcified plaques.

Entities:  

Mesh:

Year:  2014        PMID: 24700078     DOI: 10.1007/s10140-014-1214-4

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  9 in total

1.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

2.  Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.

Authors:  Stephan Achenbach; Tobias Goroll; Martin Seltmann; Tobias Pflederer; Katharina Anders; Dieter Ropers; Werner G Daniel; Michael Uder; Michael Lell; Mohamed Marwan
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

3.  Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

Authors:  Filippo Cademartiri; Erica Maffei; Anselmo Alessandro Palumbo; Roberto Malagò; Ludovico La Grutta; W Bob Meiijboom; Annachiara Aldrovandi; Michele Fusaro; Luigi Vignali; Alberto Menozzi; Valerio Brambilla; Paolo Coruzzi; Massimo Midiri; Miles A Kirchin; Nico R A Mollet; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2007-10-13       Impact factor: 5.315

4.  Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Christian Fink; Carsten Rist; Alexander W Leber; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  J Comput Assist Tomogr       Date:  2007 Mar-Apr       Impact factor: 1.826

5.  Dual-source versus single-source cardiac CT angiography: comparison of diagnostic image quality.

Authors:  Robert Donnino; Jill E Jacobs; Jay V Doshi; Elizabeth M Hecht; Danny C Kim; James S Babb; Monvadi B Srichai
Journal:  AJR Am J Roentgenol       Date:  2009-04       Impact factor: 3.959

6.  Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography.

Authors:  Christof Burgstahler; Anja Reimann; Harald Brodoefel; Ulrike Daferner; Tina Herberts; Ilias Tsiflikas; Christoph Thomas; Tanja Drosch; Stephen Schroeder; Martin Heuschmid
Journal:  Eur Radiol       Date:  2008-10-25       Impact factor: 5.315

7.  64 Slice multi-detector row cardiac CT.

Authors:  Harpreet K Pannu; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2008-10-22

8.  Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.

Authors:  Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

Review 9.  Cardiothoracic CT angiography: current contrast medium delivery strategies.

Authors:  Markus Weininger; J Michael Barraza; Corey A Kemper; John F Kalafut; Philip Costello; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2011-03       Impact factor: 3.959

  9 in total
  1 in total

1.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.