Literature DB >> 24663943

Dependent scattering in Intralipid® phantoms in the 600-1850 nm range.

Ben Aernouts, Robbe Van Beers, Rodrigo Watté, Jeroen Lammertyn, Wouter Saeys.   

Abstract

The effect of dependent scattering on the bulk scattering properties of intralipid phantoms in the 600-1850 nm wavelength range has been investigated. A set of 57 liquid optical phantoms, covering a wide range of intralipid concentrations (1-100% v/v), was prepared and the bulk optical properties were accurately determined. The bulk scattering coefficient as a function of the particle density could be well described with Twersky's packing factor (R(2) > 0.990). A general model was elaborated taking into account the wavelength dependency and the effect of the concentration of scattering particles (R(2) = 0.999). Additionally, an empirical approach was followed to characterize the effect of dense packing of scattering particles on the anisotropy factor (R(2) = 0.992) and the reduced scattering coefficient (R(2) = 0.999) of the phantoms. The derived equations can be consulted in future research for the calculation of the bulk scattering properties of intralipid dilutions in the 600-1850 nm range, or for the validation of theories that describe the effects of dependent scattering on the scattering properties of intralipid-like systems.

Year:  2014        PMID: 24663943     DOI: 10.1364/OE.22.006086

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  9 in total

1.  Capability of physically reasonable OCT-based differentiation between intact brain tissues, human brain gliomas of different WHO grades, and glioma model 101.8 from rats.

Authors:  I N Dolganova; P V Aleksandrova; P V Nikitin; A I Alekseeva; N V Chernomyrdin; G R Musina; S T Beshplav; I V Reshetov; A A Potapov; V N Kurlov; V V Tuchin; K I Zaytsev
Journal:  Biomed Opt Express       Date:  2020-10-28       Impact factor: 3.732

2.  A Deep Learning Approach to Photoacoustic Wavefront Localization in Deep-Tissue Medium.

Authors:  Kerrick Johnstonbaugh; Sumit Agrawal; Deepit Abhishek Durairaj; Christopher Fadden; Ajay Dangi; Sri Phani Krishna Karri; Sri-Rajasekhar Kothapalli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

3.  In vivo measurement of the attenuation coefficient of the sclera and ciliary muscle.

Authors:  Gabrielle Monterano Mesquita; Disha Patel; Yu-Cherng Chang; Florence Cabot; Marco Ruggeri; Sonia H Yoo; Arthur Ho; Jean-Marie A Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2021-07-20       Impact factor: 3.732

4.  Enhanced photoacoustic imaging in tissue-mimicking phantoms using polydopamine-shelled perfluorocarbon emulsion droplets.

Authors:  Mark Louis P Vidallon; Ekaterina Salimova; Simon A Crawford; Boon Mian Teo; Rico F Tabor; Alexis I Bishop
Journal:  Ultrason Sonochem       Date:  2022-05-18       Impact factor: 9.336

5.  Internal-Illumination Photoacoustic Tomography Enhanced by a Graded-Scattering Fiber Diffuser.

Authors:  Mucong Li; Tri Vu; Georgy Sankin; Brenton Winship; Kohldon Boydston; Russell Terry; Pei Zhong; Junjie Yao
Journal:  IEEE Trans Med Imaging       Date:  2020-12-29       Impact factor: 10.048

6.  Towards shifted position-diffuse reflectance imaging of anatomically correctly scaled human microvasculature.

Authors:  Moritz Späth; Martin Hohmann; Clemens Roider; Benjamin Lengenfelder; Florian Stelzle; Stefan Wirtz; Florian Klämpfl
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

7.  Lung tissue phantom mimicking pulmonary optical properties, relative humidity, and temperature: a tool to analyze the changes in oxygen gas absorption for different inflated volumes.

Authors:  Andrea Pacheco; Konstantin Grygoryev; Walter Messina; Stefan Andersson-Engels
Journal:  J Biomed Opt       Date:  2021-11       Impact factor: 3.758

8.  Direct Measurement of the Reduced Scattering Coefficient by a Calibrated Random Laser Sensor.

Authors:  Federico Tommasi; Baptiste Auvity; Lorenzo Fini; Fabrizio Martelli; Stefano Cavalieri
Journal:  Sensors (Basel)       Date:  2022-02-11       Impact factor: 3.576

9.  Improving the characterization of ex vivo human brain optical properties using high numerical aperture optical coherence tomography by spatially constraining the confocal parameters.

Authors:  Jiarui Yang; Ichun Anderson Chen; Shuaibin Chang; Jianbo Tang; Blaire Lee; Kıvılcım Kılıç; Smrithi Sunil; Hui Wang; Divya Varadarajan; Caroline Magnain; Shih-Chi Chen; Irene Costantini; Francesco Pavone; Bruce Fischl; David A Boas
Journal:  Neurophotonics       Date:  2020-10-21       Impact factor: 3.593

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.