Literature DB >> 24657104

Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters.

Finn E Donaldson1, James C Coburn2, Karen Lohmann Siegel2.   

Abstract

A variety of design and patient parameters have been implicated in recent reports of fretting corrosion at modular connections in total hip arthroplasty. We sought to identify the relative sensitivity of mechanical fretting to a comprehensive set of parameters such that attention may be focused on key variables. Stochastic finite element simulation of the head-neck taper-trunnion junction was performed. Four-hundred parameter sets were simulated using realistic variations of design variables, material properties and loading parameters to predict contact pressures (P), micromotions (M) and fretting work (coefficient of friction×P×M) over cycles of gait. Results indicated that fretting work was correlated with only three parameters: angular mismatch, center offset and body weight (r=0.47, 0.53 and 0.43, p<0.001). Maximum contact pressure increased by 85MPa for every 0.1° of angular mismatch. Maximum micromotion increased by 5µm per 10mm additional head offset and 1µm per 10kg increased body weight. Uncorrelated parameters included trunnion diameter, trunnion length and impaction forces. It was concluded that appropriate limiting of angular mismatch and center offset could minimize fretting, and hence its contribution to corrosion, at modular connections. Published by Elsevier Ltd.

Entities:  

Keywords:  Finite element analysis; Modularity; Total hip arthroplasty; Trunnionosis; Wear

Mesh:

Year:  2014        PMID: 24657104     DOI: 10.1016/j.jbiomech.2014.02.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

Review 1.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

2.  Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers.

Authors:  Maren Bechstedt; Jonathan A Gustafson; Steven P Mell; Julian Gührs; Michael M Morlock; Brett R Levine; Hannah J Lundberg
Journal:  J Biomech       Date:  2020-02-25       Impact factor: 2.712

3.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

Review 4.  Trunnion Corrosion in Total Hip Arthroplasty-Basic Concepts.

Authors:  Kenneth L Urish; Nicholas John Giori; Jack E Lemons; William M Mihalko; Nadim Hallab
Journal:  Orthop Clin North Am       Date:  2019-04-16       Impact factor: 2.472

Review 5.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

6.  CORR Insights®: Insights into Imprinting: How Is the Phenomenon of Tribocorrosion at Head-Neck Taper Interfaces Related to Corrosion, Fretting, and Implant Design Parameters?

Authors:  Mariano Fernandez-Fairen
Journal:  Clin Orthop Relat Res       Date:  2022-05-30       Impact factor: 4.755

7.  A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture.

Authors:  Stefano Lucchini; Massimiliano Baleani; Federico Giardina; Andrea Martelli; Francesco Castagnini; Barbara Bordini; Francesco Traina
Journal:  J Orthop Surg Res       Date:  2022-06-03       Impact factor: 2.677

Review 8.  [Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].

Authors:  M M Morlock; M Jäger
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

Review 9.  Review: Trunnionosis leading to modular femoral head dissociation.

Authors:  Agneish Dutta; James Nutt; Guy Slater; Syed Ahmed
Journal:  J Orthop       Date:  2021-01-30

10.  What Is the Risk of THA Revision for ARMD in Patients with Non-metal-on-metal Bearings? A Study from the Australian National Joint Replacement Registry.

Authors:  R N de Steiger; Alesha Hatton; Yi Peng; Stephen Graves
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.