Automatic segmentation of intra-cochlear anatomy in post-implantation CT of unilateral cochlear implant recipients.

Fitsum A Reda1, Theodore R McRackan2, Robert F Labadie2, Benoit M Dawant1, Jack H Noble3.   

Abstract

A cochlear implant (CI) is a neural prosthetic device that restores hearing by directly stimulating the auditory nerve using an electrode array that is implanted in the cochlea. In CI surgery, the surgeon accesses the cochlea and makes an opening where he/she inserts the electrode array blind to internal structures of the cochlea. Because of this, the final position of the electrode array relative to intra-cochlear anatomy is generally unknown. We have recently developed an approach for determining electrode array position relative to intra-cochlear anatomy using a pre- and a post-implantation CT. The approach is to segment the intra-cochlear anatomy in the pre-implantation CT, localize the electrodes in the post-implantation CT, and register the two CTs to determine relative electrode array position information. Currently, we are using this approach to develop a CI programming technique that uses patient-specific spatial information to create patient-customized sound processing strategies. However, this technique cannot be used for many CI users because it requires a pre-implantation CT that is not always acquired prior to implantation. In this study, we propose a method for automatic segmentation of intra-cochlear anatomy in post-implantation CT of unilateral recipients, thus eliminating the need for pre-implantation CTs in this population. The method is to segment the intra-cochlear anatomy in the implanted ear using information extracted from the normal contralateral ear and to exploit the intra-subject symmetry in cochlear anatomy across ears. To validate our method, we performed experiments on 30 ears for which both a pre- and a post-implantation CT are available. The mean and the maximum segmentation errors are 0.224 and 0.734mm, respectively. These results indicate that our automatic segmentation method is accurate enough for developing patient-customized CI sound processing strategies for unilateral CI recipients using a post-implantation CT alone.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cochlear implant; Cochlear implant programming; Image registration; Statistical shape model; Surface-to-image registration

Mesh:

Year:  2014        PMID: 24650801      PMCID: PMC4410997          DOI: 10.1016/j.media.2014.02.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  25 in total

1.  Computation of the mid-sagittal plane in 3-D brain images.

Authors:  Sylvain Prima; Sébastien Ourselin; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2002-02       Impact factor: 10.048

2.  Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images.

Authors:  S C Mitchell; B P Lelieveldt; R J van der Geest; H G Bosch; J H Reiber; M Sonka
Journal:  IEEE Trans Med Imaging       Date:  2001-05       Impact factor: 10.048

3.  Robust midsagittal plane extraction from normal and pathological 3-D neuroradiology images.

Authors:  Y Liu; R T Collins; W E Rothfus
Journal:  IEEE Trans Med Imaging       Date:  2001-03       Impact factor: 10.048

4.  Prenatal growth and development of the modern human labyrinth.

Authors:  Nathan Jeffery; Fred Spoor
Journal:  J Anat       Date:  2004-02       Impact factor: 2.610

5.  Better speech recognition with cochlear implants.

Authors:  B S Wilson; C C Finley; D T Lawson; R D Wolford; D K Eddington; W M Rabinowitz
Journal:  Nature       Date:  1991-07-18       Impact factor: 49.962

6.  Automatic construction of 3D-ASM intensity models by simulating image acquisition: application to myocardial gated SPECT studies.

Authors:  Catalina Tobon-Gomez; Constantine Butakoff; Santiago Aguade; Federico Sukno; Gloria Moragas; Alejandro F Frangi
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

7.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

8.  Least-squares fitting of two 3-d point sets.

Authors:  K S Arun; T S Huang; S D Blostein
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1987-05       Impact factor: 6.226

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  Automatic segmentation of intracochlear anatomy in conventional CT.

Authors:  Jack H Noble; Robert F Labadie; Omid Majdani; Benoit M Dawant
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-23       Impact factor: 4.538

View more
  15 in total

1.  Impact of the surgical experience on cochleostomy location: a comparative temporal bone study between endaural and posterior tympanotomy approaches for cochlear implantation.

Authors:  Clair Vandersteen; Thomas Demarcy; Coralie Roger; Eric Fontas; Charles Raffaelli; Nicholas Ayache; Hervé Delingette; Nicolas Guevara
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-10-16       Impact factor: 2.503

2.  Automatic localization of closely spaced cochlear implant electrode arrays in clinical CTs.

Authors:  Yiyuan Zhao; Benoit M Dawant; Robert F Labadie; Jack H Noble
Journal:  Med Phys       Date:  2018-10-08       Impact factor: 4.071

3.  Selecting electrode configurations for image-guided cochlear implant programming using template matching.

Authors:  Dongqing Zhang; Yiyuan Zhao; Jack H Noble; Benoit M Dawant
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-11

4.  Localizing landmark sets in head CTs using random forests and a heuristic search algorithm for registration initialization.

Authors:  Dongqing Zhang; Yuan Liu; Jack H Noble; Benoit M Dawant
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-08

5.  Validation of automatic cochlear implant electrode localization techniques using μ CTs.

Authors:  Yiyuan Zhao; Robert F Labadie; Benoit M Dawant; Jack H Noble
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-24

6.  Results of Postoperative, CT-based, Electrode Deactivation on Hearing in Prelingually Deafened Adult Cochlear Implant Recipients.

Authors:  Robert F Labadie; Jack H Noble; Andrea J Hedley-Williams; Linsey W Sunderhaus; Benoit M Dawant; René H Gifford
Journal:  Otol Neurotol       Date:  2016-02       Impact factor: 2.311

7.  Further Evidence of the Relationship Between Cochlear Implant Electrode Positioning and Hearing Outcomes.

Authors:  Srijata Chakravorti; Jack H Noble; René H Gifford; Benoit M Dawant; Brendan P O'Connell; Jianing Wang; Robert F Labadie
Journal:  Otol Neurotol       Date:  2019-06       Impact factor: 2.311

8.  Implementation of Image-Guided Cochlear Implant Programming at a Distant Site.

Authors:  Theodore R McRackan; Jack H Noble; Eric P Wilkinson; Dawna Mills; Mary S Dietrich; Benoit M Dawant; Rene H Gifford; Robert F Labadie
Journal:  Otolaryngol Head Neck Surg       Date:  2017-04-04       Impact factor: 3.497

9.  Correlation of Superior Canal Dehiscence Surface Area With Vestibular Evoked Myogenic Potentials, Audiometric Thresholds, and Dizziness Handicap.

Authors:  Jacob B Hunter; Brendan P O'Connell; Jianing Wang; Srijata Chakravorti; Katie Makowiec; Matthew L Carlson; Benoit Dawant; Devin L McCaslin; Jack H Noble; George B Wanna
Journal:  Otol Neurotol       Date:  2016-09       Impact factor: 2.311

10.  Random walks with shape prior for cochlea segmentation in ex vivo μCT.

Authors:  Esmeralda Ruiz Pujadas; Hans Martin Kjer; Gemma Piella; Mario Ceresa; Miguel Angel González Ballester
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-19       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.