Literature DB >> 24643022

Aneurysm coil embolization using a 1.5-fr distal outer diameter microcatheter.

David A Stidd1, Demetrius K Lopes1, Michael Chen1.   

Abstract

The current assortment of microcatheters widely used for aneurysm coil embolization may not be well suited for several anatomic variants, including excessive vascular tortuosity and small aneurysms less than 3 mm. Longer microcatheters designed with a smaller caliber that can accommodate and deliver coils may be of use in these situations. This case series and literature review illustrates the advantages and limitations of the Marathon microcatheter (Covidien, Irvine, CA, USA) when used for coil embolization of cerebral aneurysms. Despite some technical compromises including the distal marker, length, and the risk of buckling, the Marathon microcatheter was able to adequately deliver coils to achieve satisfactory occlusion of cerebral aneurysms. We found unique advantages with regards to length and smaller distal outer diameter (OD). These results may serve as a guide for the further development of a microcatheter used for coil embolization that has the features of a smaller distal OD and longer length.

Entities:  

Keywords:  Cerebral aneurysms; Coil embolization; Endovascular procedures; Microcatheter

Year:  2014        PMID: 24643022      PMCID: PMC3955821          DOI: 10.5469/neuroint.2014.9.1.39

Source DB:  PubMed          Journal:  Neurointervention        ISSN: 2093-9043


  6 in total

1.  Selective coil embolization through flow-directed microcatheter for intracranial arteriovenous malformations.

Authors:  Nobutaka Horie; Kentaro Hayashi; Minoru Morikawa; Izumi Nagata
Journal:  Acta Neurochir (Wien)       Date:  2012-02-24       Impact factor: 2.216

2.  Shapability, memory, and luminal changes in microcatheters after steam shaping: a comparison of 11 different microcatheters.

Authors:  Hiro Kiyosue; Yuzo Hori; Shunro Matsumoto; Mika Okahara; Syuichi Tanoue; Yoshiko Sagara; Hiromu Mori
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

3.  Performance characteristics of microcatheter systems in a standardized tortuous pathway.

Authors:  G H Zoarski; J M Mathis; J R Hebel
Journal:  AJNR Am J Neuroradiol       Date:  1998-09       Impact factor: 3.825

4.  Aneurysmal rupture during embolization with Guglielmi detachable coils: causes, management, and outcome.

Authors:  A Doerfler; I Wanke; T Egelhof; U Dietrich; S Asgari; D Stolke; M Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

5.  Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms: a retrospective review.

Authors:  Justin R Mascitelli; Maritsa F Polykarpou; Aanand A Patel; Ashwin A Kamath; Henry Moyle; Aman B Patel
Journal:  J Neurointerv Surg       Date:  2012-09-19       Impact factor: 5.836

6.  Direct cervical arterial access for intracranial endovascular treatment.

Authors:  R Blanc; M Piotin; C Mounayer; L Spelle; J Moret
Journal:  Neuroradiology       Date:  2006-12       Impact factor: 2.804

  6 in total
  2 in total

1.  Coil embolization through the Marathon microcatheter: Advantages and pitfalls.

Authors:  Joel S Beckett; Gary R Duckwiler; Satoshi Tateshima; Viktor Szeder; Reza Jahan; Nestor Gonzalez; Fernando Vinuela
Journal:  Interv Neuroradiol       Date:  2016-10-27       Impact factor: 1.610

2.  Electronically integrated microcatheters based on self-assembling polymer films.

Authors:  Boris Rivkin; Christian Becker; Balram Singh; Azaam Aziz; Farzin Akbar; Aleksandr Egunov; Dmitriy D Karnaushenko; Ronald Naumann; Rudolf Schäfer; Mariana Medina-Sánchez; Daniil Karnaushenko; Oliver G Schmidt
Journal:  Sci Adv       Date:  2021-12-17       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.