Literature DB >> 24638894

Pulse oximetry for perioperative monitoring.

Tom Pedersen1, Amanda Nicholson, Karen Hovhannisyan, Ann Merete Møller, Andrew F Smith, Sharon R Lewis.   

Abstract

BACKGROUND: This is an update of a review last published in Issue 9, 2009, of The Cochrane Library. Pulse oximetry is used extensively in the perioperative period and might improve patient outcomes by enabling early diagnosis and, consequently, correction of perioperative events that might cause postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry during anaesthesia and in the recovery room have been performed that describe perioperative hypoxaemic events, postoperative cardiopulmonary complications and cognitive dysfunction.
OBJECTIVES: To study the use of perioperative monitoring with pulse oximetry to clearly identify adverse outcomes that might be prevented or improved by its use.The following hypotheses were tested.1. Use of pulse oximetry is associated with improvement in the detection and treatment of hypoxaemia.2. Early detection and treatment of hypoxaemia reduce morbidity and mortality in the perioperative period.3. Use of pulse oximetry per se reduces morbidity and mortality in the perioperative period.4. Use of pulse oximetry reduces unplanned respiratory admissions to the intensive care unit (ICU), decreases the length of ICU readmission or both. SEARCH
METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 5), MEDLINE (1966 to June 2013), EMBASE (1980 to June 2013), CINAHL (1982 to June 2013), ISI Web of Science (1956 to June 2013), LILACS (1982 to June 2013) and databases of ongoing trials; we also checked the reference lists of trials and review articles. The original search was performed in January 2005, and a previous update was performed in May 2009. SELECTION CRITERIA: We included all controlled trials that randomly assigned participants to pulse oximetry or no pulse oximetry during the perioperative period. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed data in relation to events detectable by pulse oximetry, any serious complications that occurred during anaesthesia or in the postoperative period and intraoperative or postoperative mortality. MAIN
RESULTS: The last update of the review identified five eligible studies. The updated search found one study that is awaiting assessment but no additional eligible studies. We considered studies with data from a total of 22,992 participants that were eligible for analysis. These studies gave insufficient detail on the methods used for randomization and allocation concealment. It was impossible for study personnel to be blinded to participant allocation in the study, as they needed to be able to respond to oximetry readings. Appropriate steps were taken to minimize detection bias for hypoxaemia and complication outcomes. Results indicated that hypoxaemia was reduced in the pulse oximetry group, both in the operating theatre and in the recovery room. During observation in the recovery room, the incidence of hypoxaemia in the pulse oximetry group was 1.5 to three times less. Postoperative cognitive function was independent of perioperative monitoring with pulse oximetry. A single study in general surgery showed that postoperative complications occurred in 10% of participants in the oximetry group and in 9.4% of those in the control group. No statistically significant differences in cardiovascular, respiratory, neurological or infectious complications were detected in the two groups. The duration of hospital stay was a median of five days in both groups, and equal numbers of in-hospital deaths were reported in the two groups. Continuous pulse oximetry has the potential to increase vigilance and decrease pulmonary complications after cardiothoracic surgery; however, routine continuous monitoring did not reduce transfer to an ICU and did not decrease overall mortality. AUTHORS'
CONCLUSIONS: These studies confirmed that pulse oximetry can detect hypoxaemia and related events. However, we found no evidence that pulse oximetry affects the outcome of anaesthesia for patients. The conflicting subjective and objective study results, despite an intense methodical collection of data from a relatively large general surgery population, indicate that the value of perioperative monitoring with pulse oximetry is questionable in relation to improved reliable outcomes, effectiveness and efficiency. Routine continuous pulse oximetry monitoring did not reduce transfer to the ICU and did not decrease mortality, and it is unclear whether any real benefit was derived from the application of this technology for patients recovering from cardiothoracic surgery in a general care area.

Entities:  

Mesh:

Year:  2014        PMID: 24638894      PMCID: PMC6464860          DOI: 10.1002/14651858.CD002013.pub3

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  35 in total

1.  Neurobehavioral outcomes in cardiac operations. A prospective controlled study.

Authors:  B D Townes; G Bashein; T F Hornbein; D B Coppel; D E Goldstein; K B Davis; M L Nessly; S W Bledsoe; R C Veith; T D Ivey
Journal:  J Thorac Cardiovasc Surg       Date:  1989-11       Impact factor: 5.209

Review 2.  Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care.

Authors:  Amit Shah; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2013-01-12       Impact factor: 2.502

3.  Long-term postoperative cognitive dysfunction in the elderly ISPOCD1 study. ISPOCD investigators. International Study of Post-Operative Cognitive Dysfunction.

Authors:  J T Moller; P Cluitmans; L S Rasmussen; P Houx; H Rasmussen; J Canet; P Rabbitt; J Jolles; K Larsen; C D Hanning; O Langeron; T Johnson; P M Lauven; P A Kristensen; A Biedler; H van Beem; O Fraidakis; J H Silverstein; J E Beneken; J S Gravenstein
Journal:  Lancet       Date:  1998-03-21       Impact factor: 79.321

4.  Hypoxaemia is reduced by pulse oximetry monitoring in the operating theatre and in the recovery room.

Authors:  J T Moller; P F Jensen; N W Johannessen; K Espersen
Journal:  Br J Anaesth       Date:  1992-02       Impact factor: 9.166

5.  A single-blind study of combined pulse oximetry and capnography in children.

Authors:  C J Coté; N Rolf; L M Liu; N G Goudsouzian; J F Ryan; A Zaslavsky; R Gore; T D Todres; S Vassallo; D Polaner
Journal:  Anesthesiology       Date:  1991-06       Impact factor: 7.892

6.  Perioperative monitoring with pulse oximetry and late postoperative cognitive dysfunction.

Authors:  J T Moller; I Svennild; N W Johannessen; P F Jensen; K Espersen; J S Gravenstein; J B Cooper; M Djernes; S H Johansen
Journal:  Br J Anaesth       Date:  1993-09       Impact factor: 9.166

7.  A single-blind study of pulse oximetry in children.

Authors:  C J Coté; E A Goldstein; M A Coté; D C Hoaglin; J F Ryan
Journal:  Anesthesiology       Date:  1988-02       Impact factor: 7.892

8.  Randomized evaluation of pulse oximetry in 20,802 patients: I. Design, demography, pulse oximetry failure rate, and overall complication rate.

Authors:  J T Moller; T Pedersen; L S Rasmussen; P F Jensen; B D Pedersen; O Ravlo; N H Rasmussen; K Espersen; N W Johannessen; J B Cooper
Journal:  Anesthesiology       Date:  1993-03       Impact factor: 7.892

Review 9.  Complications and death following anaesthesia. A prospective study with special reference to the influence of patient-, anaesthesia-, and surgery-related risk factors.

Authors:  T Pedersen
Journal:  Dan Med Bull       Date:  1994-06

10.  Anesthesia related hypoxemia. The effect of pulse oximetry monitoring on perioperative events and postoperative complications.

Authors:  J T Møller
Journal:  Dan Med Bull       Date:  1994-11
View more
  29 in total

1.  Usefulness of oxygen reserve index (ORi™), a new parameter of oxygenation reserve potential, for rapid sequence induction of general anesthesia.

Authors:  Keisuke Yoshida; Tsuyoshi Isosu; Yoshie Noji; Makiko Hasegawa; Yuzo Iseki; Rieko Oishi; Tsuyoshi Imaizumi; Norie Sanbe; Shinju Obara; Masahiro Murakawa
Journal:  J Clin Monit Comput       Date:  2017-09-27       Impact factor: 2.502

2.  Incidence of hypoxia and related events detected by pulse oximeters provided by the Lifebox Foundation in the maternity unit at Sylvanus Olympio University Teaching Hospital, Togo.

Authors:  H D Sama; A F Ouro Bang'na Maman; I A Walker
Journal:  J Anesth       Date:  2015-07-22       Impact factor: 2.078

3.  [Clinical relevance of NIRS-based cerebral oximetry 2.0].

Authors:  Matthias Heringlake; Hauke Paarmann
Journal:  Anaesthesist       Date:  2021-03-01       Impact factor: 1.041

4.  A proposed algorithm for combining transcranial Doppler ultrasound monitoring with cerebral and somatic oximetry: a case report.

Authors:  Milène A Azzam; Etienne J Couture; William Beaubien-Souligny; Patrice Brassard; Caroline E Gebhard; André Y Denault
Journal:  Can J Anaesth       Date:  2020-10-15       Impact factor: 5.063

5.  Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.

Authors:  Barak Pertzov; Elitsur Brachfeld; Avraham Unterman; Evgeni Gershman; Nader Abdel-Rahman; Dror Rosengarten; Mordechai Reuven Kramer
Journal:  Lung       Date:  2018-11-24       Impact factor: 2.584

6.  A risk stratification algorithm using non-invasive respiratory volume monitoring to improve safety when using post-operative opioids in the PACU.

Authors:  Christopher Voscopoulos; Kimberly Theos; H A Tillmann Hein; Edward George
Journal:  J Clin Monit Comput       Date:  2016-02-19       Impact factor: 2.502

Review 7.  Myths, fallacies and practical pearls in GI lab.

Authors:  Pradeep Kumar
Journal:  World J Gastrointest Endosc       Date:  2014-12-16

8.  Evaluation of a wireless, portable, wearable multi-parameter vital signs monitor in hospitalized neurological and neurosurgical patients.

Authors:  Robert S Weller; Kristina L Foard; Timothy N Harwood
Journal:  J Clin Monit Comput       Date:  2017-12-06       Impact factor: 2.502

Review 9.  Cerebral near-infrared spectroscopy in the care of patients during cardiological procedures: a summary of the clinical evidence.

Authors:  Annelies Moerman; Frederik Meert; Stefan De Hert
Journal:  J Clin Monit Comput       Date:  2015-10-08       Impact factor: 2.502

10.  Study of early warning for desaturation provided by Oxygen Reserve Index in obese patients.

Authors:  Ekaterina Tsymbal; Sebastian Ayala; Amrik Singh; Richard L Applegate; Neal W Fleming
Journal:  J Clin Monit Comput       Date:  2020-05-18       Impact factor: 2.502

View more