Literature DB >> 24633646

Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Rebecca T Hahn1, Susheel Kodali, Philippe Généreux, Martin Leon.   

Abstract

Despite the higher incidence of paravalvular regurgitation (PVR) with transcatheter aortic valve replacement (TAVR), this novel treatment modality has rapidly emerged as a reasonable alternative to surgical aortic valve replacement (SAVR) in high risk and inoperable patients. This review will discuss the current literature with respect to assessment, outcomes, predictors, and intraprocedural treatment options of PVR following TAVR. Understanding the predictors may help reduce the incidence of PVR and improving the outcome of this procedure.

Entities:  

Mesh:

Year:  2014        PMID: 24633646     DOI: 10.1007/s11886-014-0475-6

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  87 in total

1.  Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation.

Authors:  Ronen Gurvitch; John G Webb; Ren Yuan; Mark Johnson; Cameron Hague; Alexander B Willson; Stefan Toggweiler; David A Wood; Jian Ye; Robert Moss; Christopher R Thompson; Stephan Achenbach; James K Min; Troy M Labounty; Ricardo Cury; Jonathon Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2011-11       Impact factor: 11.195

2.  Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry.

Authors:  Neil E Moat; Peter Ludman; Mark A de Belder; Ben Bridgewater; Andrew D Cunningham; Christopher P Young; Martyn Thomas; Jan Kovac; Tom Spyt; Philip A MacCarthy; Olaf Wendler; David Hildick-Smith; Simon W Davies; Uday Trivedi; Daniel J Blackman; Richard D Levy; Stephen J D Brecker; Andreas Baumbach; Tim Daniel; Huon Gray; Michael J Mullen
Journal:  J Am Coll Cardiol       Date:  2011-10-20       Impact factor: 24.094

3.  Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement: the potential role of subjectively overestimated operative risk.

Authors:  David S Bach; Derrick Siao; Steven E Girard; Claire Duvernoy; Benjamin D McCallister; Sarah K Gualano
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2009-10-27

4.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

5.  Outcome of 622 adults with asymptomatic, hemodynamically significant aortic stenosis during prolonged follow-up.

Authors:  Patricia A Pellikka; Maurice E Sarano; Rick A Nishimura; Joseph F Malouf; Kent R Bailey; Christopher G Scott; Marion E Barnes; A Jamil Tajik
Journal:  Circulation       Date:  2005-06-13       Impact factor: 29.690

6.  Prediction of paravalvular regurgitation after transcatheter aortic valve implantation by computed tomography: value of aortic valve and annular calcification.

Authors:  Gudrun Feuchtner; Fabian Plank; Thomas Bartel; Silvana Mueller; Jonathon Leipsic; Thomas Schachner; Ludwig Müller; Guy Friedrich; Andrea Klauser; Michael Grimm; Nikolaos Bonaros
Journal:  Ann Thorac Surg       Date:  2013-09-24       Impact factor: 4.330

Review 7.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2012-10-09       Impact factor: 24.094

8.  Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.

Authors:  Hasan Jilaihawi; Niraj Doctor; Mohammad Kashif; Tarun Chakravarty; Asim Rafique; Moody Makar; Azusa Furugen; Mamoo Nakamura; James Mirocha; Mitch Gheorghiu; Jasminka Stegic; Kazuaki Okuyama; Daniel J Sullivan; Robert Siegel; James K Min; Swaminatha V Gurudevan; Gregory P Fontana; Wen Cheng; Gerald Friede; Takahiro Shiota; Raj R Makkar
Journal:  J Am Coll Cardiol       Date:  2013-03-05       Impact factor: 24.094

9.  Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement.

Authors:  Benoit Daneault; Elana Koss; Rebecca T Hahn; Susheel Kodali; Mathew R Williams; Philippe Généreux; Jean-Michel Paradis; Isaac George; George R Reiss; Jeffrey W Moses; Craig R Smith; Martin B Leon
Journal:  Circ Cardiovasc Interv       Date:  2013-01-22       Impact factor: 6.546

10.  Incidence, predictive factors and haemodynamic consequences of acute stent recoil following transcatheter aortic valve implantation with a balloon-expandable valve.

Authors:  Luis Nombela-Franco; Henrique B Ribeiro; Marina Urena; Sergio Pasian; Ricardo Allende; Daniel Doyle; Robert Delarochellière; Hugo Delarochellière; Louis Laflamme; Jerôme Laflamme; Miguel Jerez-Valero; Melanie Côté; Philippe Pibarot; Eric Larose; Eric Dumont; Josep Rodés-Cabau
Journal:  EuroIntervention       Date:  2014       Impact factor: 6.534

View more
  2 in total

1.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

Review 2.  Vascular Imaging Before Transcatheter Aortic Valve Replacement (TAVR): Why and How?

Authors:  Damiano Caruso; Russell D Rosenberg; Carlo N De Cecco; Stefanie Mangold; Julian L Wichmann; Akos Varga-Szemes; Daniel H Steinberg; Andrea Laghi; U Joseph Schoepf
Journal:  Curr Cardiol Rep       Date:  2016-02       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.