Literature DB >> 2431130

Pulse oximetry for continuous oxygen monitoring in sick newborn infants.

M Durand, R Ramanathan.   

Abstract

We studied 54 neonates with acute cardiorespiratory illness and 21 infants with bronchopulmonary dysplasia, to evaluate the accuracy of a nonheated pulse oximeter in predicting arterial oxygen saturation (SaO2). We also studied the accuracy of transcutaneous oxygen tension (tcPO2) in estimating arterial oxygen tension (PaO2) in infants with bronchopulmonary dysplasia. We compared pulse oximeter SaO2 with simultaneously measured SaO2 (range 78% to 100%) using a co-oximeter. Over a wide range of values for heart rate, blood pressure, hematocrit, PO2, PCO2, and pH, linear regression analysis revealed a close correlation between in vivo pulse oximeter readings and in vitro SaO2 measurements in patients with acute (r = 0.86, Y = 29.64 + 0.68X) and chronic (r = 0.91, Y = 6.29 + 0.96X) disease. Regression analysis of tcPO2 versus PaO2 showed an r value of 0.76 in infants with bronchopulmonary dysplasia. In these patients the mean difference between pulse oximeter SaO2 and in vitro SaO2 was 2.9% +/- 1.8% (SD), whereas the mean difference between tcPO2 and PaO2 was -14.5 +/- 11.1 mm Hg. Fetal hemoglobin ranged from 4.3% to 95%. We conclude that pulse oximetry is an appropriate alternative to tcPO2 for continuous oxygen monitoring in newborn infants with acute cardiorespiratory illnesses and chronic lung disease.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2431130     DOI: 10.1016/s0022-3476(86)80298-0

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  14 in total

Review 1.  Non-invasive monitoring in the pediatric ICU, Part III: Pulse oximeter.

Authors:  T Ravindranath
Journal:  Indian J Pediatr       Date:  1990 Mar-Apr       Impact factor: 1.967

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

3.  Non-invasive oxygen saturation monitoring in neonates.

Authors:  K Dziedzic; D Vidyasagar
Journal:  Indian J Pediatr       Date:  1989 Sep-Oct       Impact factor: 1.967

4.  Pulse oximetry reference values at high altitude.

Authors:  J M Lozano; O R Duque; T Buitrago; S Behaine
Journal:  Arch Dis Child       Date:  1992-03       Impact factor: 3.791

Review 5.  Uses and abuses of pulse oximetry.

Authors:  J T Moyle
Journal:  Arch Dis Child       Date:  1996-01       Impact factor: 3.791

6.  Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry.

Authors:  A P Harris; M J Sendak; R T Donham; M Thomas; D Duncan
Journal:  J Clin Monit       Date:  1988-07

7.  Transcutaneous oxygen saturation in sleeping infants: prone and supine.

Authors:  S Levene; S A McKenzie
Journal:  Arch Dis Child       Date:  1990-05       Impact factor: 3.791

Review 8.  Oxygen therapy for infants with chronic lung disease.

Authors:  S Kotecha; J Allen
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

9.  Reference values for pulse oximetry at high altitude.

Authors:  M J Gamponia; H Babaali; F Yugar; R H Gilman
Journal:  Arch Dis Child       Date:  1998-05       Impact factor: 3.791

10.  Oxygen desaturation complicates feeding in infants with bronchopulmonary dysplasia after discharge.

Authors:  L Singer; R J Martin; S W Hawkins; L J Benson-Szekely; T S Yamashita; W A Carlo
Journal:  Pediatrics       Date:  1992-09       Impact factor: 7.124

View more