ICSH guidelines for the verification and performance of automated cell counters for body fluids.

G Bourner1, B De la Salle, T George, Y Tabe, H Baum, N Culp, T B Keng.   

Abstract

One of the many challenges facing laboratories is the verification of their automated Complete Blood Count cell counters for the enumeration of body fluids. These analyzers offer improved accuracy, precision, and efficiency in performing the enumeration of cells compared with manual methods. A patterns of practice survey was distributed to laboratories that participate in proficiency testing in Ontario, Canada, the United States, the United Kingdom, and Japan to determine the number of laboratories that are testing body fluids on automated analyzers and the performance specifications that were performed. Based on the results of this questionnaire, an International Working Group for the Verification and Performance of Automated Cell Counters for Body Fluids was formed by the International Council for Standardization in Hematology (ICSH) to prepare a set of guidelines to help laboratories plan and execute the verification of their automated cell counters to provide accurate and reliable results for automated body fluid counts. These guidelines were discussed at the ICSH General Assemblies and reviewed by an international panel of experts to achieve further consensus.
© 2014 John Wiley & Sons Ltd.

Keywords:  Automated cell counts; body fluids; cerebrospinal fluid; verification

Mesh:

Year:  2014        PMID: 24628711     DOI: 10.1111/ijlh.12196

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  6 in total

1.  Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.

Authors:  Sabrina Buoro; Sara Apassiti Esposito; MariaGrazia Alessio; Alberto Crippa; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2015-08-24       Impact factor: 2.352

2.  Continuous ambulatory peritoneal dialysis, ascitic and pleural body fluids evaluation with the Mindray BC-6800 hematology analyzer.

Authors:  Oscar Fuster; Belinda Andino; Amparo Pardo; Begoña Laiz
Journal:  J Clin Lab Anal       Date:  2017-04-26       Impact factor: 2.352

3.  Automated analysis for differentiating leukocytes in body fluids using the software "biological liquid application" on ADVIA2120/2120i hematology analyzer.

Authors:  Alessandra Falda; Paolo Doretto
Journal:  J Clin Lab Anal       Date:  2018-05-25       Impact factor: 2.352

4.  A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment.

Authors:  Jiwon Lee; Younggeun Cho; Han-Sung Kim; Hee Jung Kang; Miyoung Kim; Young Kyung Lee
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

5.  Performance Evaluation of Body Fluid Cellular Analysis Using the Beckman Coulter UniCel DxH 800, Sysmex XN-350, and UF-5000 Automated Cellular Analyzers.

Authors:  Jooyoung Cho; Joowon Oh; Sang Guk Lee; You Hee Lee; Jaewoo Song; Jeong Ho Kim
Journal:  Ann Lab Med       Date:  2020-03       Impact factor: 3.464

6.  Clinical usefulness of fully automated chemiluminescent immunoassay for quantitative antibody measurements in COVID-19 patients.

Authors:  Reza Soleimani; Mehdi Khourssaji; Damien Gruson; Hector Rodriguez-Villalobos; Mathilde Berghmans; Leila Belkhir; Jean-Cyr Yombi; Benoît Kabamba-Mukadi
Journal:  J Med Virol       Date:  2020-08-24       Impact factor: 20.693

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.