Literature DB >> 24621428

Planning target volume-to-skin proximity for head-and-neck intensity modulated radiation therapy treatment planning.

Robert A Price1, Sion Koren2, Iavor Veltchev2, Murshed Hossain2, Mu-Han Lin2, Thomas Galloway2, Patrice Flanagan2, Jonah Haber2, Chang-Ming Ma2.   

Abstract

PURPOSE: The goal of this work is to evaluate planning target volume (PTV)-to-skin proximity versus plan quality as well as the effects of calculation voxel size on dose uncertainty in the surface region. METHODS AND MATERIALS: A right-sided clinical target volume with the lateral border 5 mm from the surface was delineated on the computed tomographic data of a head-and-neck phantom. A 5-mm PTV expansion was generated except laterally where distances of 0-5 mm were used. A 7-field intensity modulated radiation therapy plan was generated using the Eclipse treatment planning system. Optimization was performed where 95% of the PTV receives the prescription dose using a voxel size of 2 mm(3). Dose calculations were repeated for voxel sizes of 1, 3, and 5 mm(3). For each plan, 9 point dose values were obtained just inside the phantom surface, corresponding to a 2 cm × 2 cm grid near the central target region. Nine ultrathin thermoluminescent dosimeters were placed on the phantom surface corresponding to the grid. Measured and calculated dose values were compared. Conformality, homogeneity, and target coverage were compared as well. This process was repeated for volumetric modulated arc therapy (VMAT) calculated with a 2-mm(3) voxel size.
RESULTS: Surface dose is overestimated by the treatment planning system (TPS) by approximately 21% and 9.5% for 5- and 3-mm(3) voxels, respectively, and is accurately predicted for 2-mm(3) voxels. A voxel size of 1 mm(3) results in underestimation by 11%. Conformality improves with increasing PTV-to-skin distance and a conformality index of unity is obtained for grid sizes between 1 and 3 mm(3) and PTV-to-skin distances of 4-4.5 mm. Hot spot also improves and falls below 110% at 4-mm PTV-to-skin distance. Underdosage worsens as the PTV approaches the skin. All of the above appear to hold for volumetric modulated arc therapy.
CONCLUSIONS: For decreasing PTV-to-skin distance with this TPS, isodose conformality decreases, "hot spot" increases, and target coverage degrades. Surface dose is overestimated when voxel sizes greater than 2 mm(3) are chosen, and underestimated for smaller voxels.
Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24621428      PMCID: PMC4159951          DOI: 10.1016/j.prro.2013.04.002

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  7 in total

1.  Superficial doses from serial tomotherapy delivery.

Authors:  S Mutic; D A Low
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT).

Authors:  Simon J Thomas; Andrew C F Hoole
Journal:  Phys Med Biol       Date:  2004-11-07       Impact factor: 3.609

3.  Experimental evaluation of the impact of different head-and-neck intensity-modulated radiation therapy planning techniques on doses to the skin and shallow targets.

Authors:  Laurence E Court; Roy B Tishler
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-01       Impact factor: 7.038

Review 4.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning.

Authors:  B Fraass; K Doppke; M Hunt; G Kutcher; G Starkschall; R Stern; J Van Dyke
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

5.  Dosimetric verification of surface and superficial doses for head and neck IMRT with different PTV shrinkage margins.

Authors:  An-Cheng Shiau; Pei-Ling Lai; Ji-An Liang; Pei-Wei Shueng; Wei-Li Chen; Wei-Peng Kuan
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

6.  Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer.

Authors:  Heeteak Chung; Hosang Jin; James F Dempsey; Chihray Liu; Jatinder Palta; Tae-Suk Suh; Siyong Kim
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

7.  Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma.

Authors:  Nancy Lee; Cynthia Chuang; Jeanne M Quivey; Theodore L Phillips; Pam Akazawa; Lynn J Verhey; Ping Xia
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-01       Impact factor: 7.038

  7 in total
  1 in total

1.  Conformal orbit sparing radiation therapy: a treatment option for advanced skin cancer of the parotid and ear region.

Authors:  Heath Foley; Shane Hopley; Elizabeth Brown; Anne Bernard; Matthew Foote
Journal:  J Med Radiat Sci       Date:  2016-03-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.