Literature DB >> 16193799

Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer.

Heeteak Chung1, Hosang Jin, James F Dempsey, Chihray Liu, Jatinder Palta, Tae-Suk Suh, Siyong Kim.   

Abstract

Despite much development, there remains dosimetric uncertainty in the surface and build-up regions in intensity-modulated radiation therapy treatment plans for head and neck cancers. Experiments were performed to determine the dosimetric discrepancies in the surface and build-up region between the treatment planning system (TPS) prediction and experimental measurement using radiochromic film. A head and neck compression film phantom was constructed from two semicylindrical solid water slabs. Treatment plans were generated using two commercial TPSs (PINNACLE3 and CORVUS) for two cases, one with a shallow (approximately 0.5 cm depth) target and another with a deep (approximately 6 cm depth) target. The plans were evaluated for a 54 Gy prescribed dose. For each case, two pieces of radiochromic film were used for dose measurement. A small piece of film strip was placed on the surface and another was inserted within the phantom. Overall, both TPSs showed good agreement with the measurement. For the shallow target case, the dose differences were within +/- 300 cGy (5.6% with respect to the prescribed dose) for PINNACLE3 and +/- 240 cGy (4.4%) for CORVUS in 90% of the region of interest. For the deep target case, the dose differences were +/- 350 (6.5%) for PINNACLE3 and +/- 260 cGy (4.8%) for CORVUS in 90% of the region of interest. However, it was found that there were significant discrepancies from the surface to about 0.2 cm in depth for both the shallow and deep target cases. It was concluded that both TPSs overestimated the surface dose for both shallow and deep target cases. The amount of overestimation ranges from 400 to 1000 cGy (approximately 7.4% to 18.5% with respect to the prescribed dose, 5400 cGy).

Entities:  

Mesh:

Year:  2005        PMID: 16193799     DOI: 10.1118/1.1992067

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields.

Authors:  Shu-Hui Hsu; Jean M Moran; Yu Chen; Ravi Kulasekere; Peter L Roberson
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Authors:  Rongxiao Zhang; Adam K Glaser; David J Gladstone; Colleen J Fox; Brian W Pogue
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Target-to-background enhancement in multispectral endoscopy with background autofluorescence mitigation for quantitative molecular imaging.

Authors:  Chenying Yang; Vivian W Hou; Emily J Girard; Leonard Y Nelson; Eric J Seibel
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

4.  The impact of direct aperture optimization on plan quality and efficiency in complex head and neck IMRT.

Authors:  Marcello Sabatino; Matthias Kretschmer; Klemens Zink; Florian Würschmidt
Journal:  Radiat Oncol       Date:  2012-01-23       Impact factor: 3.481

5.  Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Authors:  Rongxiao Zhang; Colleen J Fox; Adam K Glaser; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2013-07-24       Impact factor: 3.609

6.  Planning target volume-to-skin proximity for head-and-neck intensity modulated radiation therapy treatment planning.

Authors:  Robert A Price; Sion Koren; Iavor Veltchev; Murshed Hossain; Mu-Han Lin; Thomas Galloway; Patrice Flanagan; Jonah Haber; Chang-Ming Ma
Journal:  Pract Radiat Oncol       Date:  2013-05-21

7.  Dose distribution comparison in volumetric-modulated arc therapy plans for head and neck cancers with and without an external body contour extended technique.

Authors:  Yoshihiro Tanaka; Hajime Monzen; Kenji Matsumoto; Shinichiro Inomata; Toshiaki Fuse
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-02

8.  Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers.

Authors:  S Xu; C Xie; Z Ju; X Dai; H Gong; L Wang; J Yang
Journal:  Biomed Imaging Interv J       Date:  2010-04-01

9.  Impact of 6MV photon beam attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery.

Authors:  R K Munjal; P S Negi; A G Babu; S N Sinha; A K Anand; T Kataria
Journal:  J Med Phys       Date:  2006-04

10.  Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy.

Authors:  Fundagul Andic; Yasemin Ors; Rima Davutoglu; Sule Baz Cifci; Emine Burcin Ispir; Mehmet Ertugrul Erturk
Journal:  J Exp Clin Cancer Res       Date:  2009-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.