Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma.

Nancy Lee1, Cynthia Chuang, Jeanne M Quivey, Theodore L Phillips, Pam Akazawa, Lynn J Verhey, Ping Xia.   

Abstract

PURPOSE: To investigate the cause of acute skin toxicity observed in the treatment of head-and-neck cancer with extended-field intensity-modulated radiotherapy (EF-IMRT). METHODS AND MATERIALS: EF-IMRT was used to treat head-and-neck cancer, with the gross target volume receiving 70 Gy and the clinical target volume 60 Gy. A thermoplastic mask covering the head, neck, and shoulder was used for immobilization. Dosimetric studies were conducted to investigate the possible causes of the skin reactions, such as the bolus effect of the mask, the use of multiple tangential beams with IMRT plans, and the way in which the physicians contoured the lymph nodes. The dose-volume histograms of conventional opposed-lateral fields were compared with that of the multiple tangential EF-IMRT fields. IMRT plans with neck nodes contoured up to and including the skin surface were compared with plans that contoured the neck nodes 5 mm away from the skin surface. In addition, IMRT plans defining the skin as a sensitive structure were compared with plans that did not define the skin as a sensitive structure. All plans were created using an anthropomorphic Rando phantom, and the skin doses were measured with and without the mask. In each measurement, 6 thermoluminescent dosimeters (TLDs) were placed at the lateral and medial surfaces of the neck.
RESULTS: For all four plans, the measured skin doses with the mask were consistently higher than those without the mask. The average dose increase was about 18% owing to the bolus effect of the mask. Multiple tangential fields used in IMRT plans contributed to an increase in skin dose by about 19% and 27%, with and without the mask, respectively. If the skin of the neck was contoured as a sensitive structure for dose optimization, the volume of skin that received >45 Gy was further reduced by about 20%. Five patients immobilized with head and shoulder masks were treated with EF-IMRT plans with the neck nodes carefully delineated away from the skin surface. The neck skin was identified as a sensitive structure for dose optimization. Grade 1 toxicity was observed in 3 patients, Grade 2 in 1 patient, and Grade 3 in 1 patient toward the end of treatment.
CONCLUSION: Multiple factors contributed to the observed acute skin reaction for head-and-neck cancer patients treated with EF-IMRT. By taking into consideration the skin as a sensitive structure during inverse planning, it was possible to reduce the skin dose to a tolerable level without compromising tumor target coverage.

Entities:  

Mesh:

Year:  2002        PMID: 12062606     DOI: 10.1016/s0360-3016(02)02756-6

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  46 in total

Review 1.  Balancing risk and reward in target delineation for highly conformal radiotherapy in head and neck cancer.

Authors:  Avraham Eisbruch; Vincent Gregoire
Journal:  Semin Radiat Oncol       Date:  2009-01       Impact factor: 5.934

2.  Comparison of surface dose delivered by 7 MV-unflattened and 6 MV-flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

3.  PET-based prognostic survival model after radiotherapy for head and neck cancer.

Authors:  Joël Castelli; A Depeursinge; A Devillers; B Campillo-Gimenez; Y Dicente; J O Prior; E Chajon; F Jegoux; C Sire; O Acosta; E Gherga; X Sun; B De Bari; J Bourhis; R de Crevoisier
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-08-21       Impact factor: 9.236

4.  Preemptive treatment with Xonrid®, a medical device to reduce radiation induced dermatitis in head and neck cancer patients receiving curative treatment: a pilot study.

Authors:  Nicola Alessandro Iacovelli; Simona Naimo; Francesca Bonfantini; Anna Cavallo; Paolo Bossi; Carlo Fallai; Emanuele Pignoli; Salvatore Alfieri; Cristiana Bergamini; Federica Favales; Ester Orlandi
Journal:  Support Care Cancer       Date:  2017-01-20       Impact factor: 3.603

5.  The effects on pain and activity of daily living caused by crusted exudation in patients with head and neck cancer treated with cetuximab and radiotherapy.

Authors:  Elvio G Russi; Marco C Merlano; Gianmauro Numico; Renzo Corvò; Marco Benasso; Riccardo Vigna-Taglianti; Antonella Melano; Nerina Denaro; Stefano Pergolizzi; Ida Colantonio; Francesco Lucio; Rodolfo Brizio; Umberto Ricardi
Journal:  Support Care Cancer       Date:  2011-11-13       Impact factor: 3.603

6.  External-beam accelerated partial breast irradiation using multiple proton beam configurations.

Authors:  Xiaochun Wang; Richard A Amos; Xiaodong Zhang; Phillip J Taddei; Wendy A Woodward; Karen E Hoffman; Tse Kuan Yu; Welela Tereffe; Julia Oh; George H Perkins; Mohammad Salehpour; Sean X Zhang; Tzou Liang Sun; Michael Gillin; Thomas A Buchholz; Eric A Strom
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-12       Impact factor: 7.038

7.  A phase I/II study of altered fractionated IMRT alone for intermediate T-stage oropharyngeal carcinoma.

Authors:  G Brandon Gunn; Eugene J Endres; Brent Parker; Maria Pia Sormani; Giuseppe Sanguineti
Journal:  Strahlenther Onkol       Date:  2010-08-30       Impact factor: 3.621

8.  A Kindler syndrome-associated squamous cell carcinoma treated with radiotherapy.

Authors:  Ademar Caldeira; William Correia Trinca; Thais Pires Flores; Andrea Barleze Costa; Claudio de Sá Brito; Karen Loureiro Weigert; Maryana Schwartzhaupt Matos; Carmela Nicolini; Fernando Mariano Obst
Journal:  Rep Pract Oncol Radiother       Date:  2016-09-10

9.  Reduction of Potential Risk for Skin Toxicity in Megavoltage Radiotherapy Using a Novel Rigid Couch.

Authors:  Mikoto Tamura; Hajime Monzen; Kenji Matsumoto; Masahiko Okumura; Hiroshi Doi; Yasumasa Nishimura
Journal:  In Vivo       Date:  2018 May-Jun       Impact factor: 2.155

10.  Planning target volume-to-skin proximity for head-and-neck intensity modulated radiation therapy treatment planning.

Authors:  Robert A Price; Sion Koren; Iavor Veltchev; Murshed Hossain; Mu-Han Lin; Thomas Galloway; Patrice Flanagan; Jonah Haber; Chang-Ming Ma
Journal:  Pract Radiat Oncol       Date:  2013-05-21