Literature DB >> 24599621

Intraosseous rotation of the scaphoid: assessment by using a 3D CT model--an anatomic study.

Gernot Schmidle1, Michael Rieger, Andrea Sabine Klauser, Michael Thauerer, Romed Hoermann, Markus Gabl.   

Abstract

OBJECTIVES: The purpose of this study was to assess intraosseous rotation as the third dimension of scaphoid anatomy on a 3D CT model using common volume rendering software to impact anatomical reconstruction of scaphoid fractures.
METHODS: CT images of 13 cadaver wrist pairs were acquired. Reference axes for the alignment of distal and proximal scaphoid poles were defined three-dimensionally. Two methods for rotation measurement-the reference axis method (RAM) and the scapho-trapezio-trapezoidal joint method (STTM)-were developed and compared by three independent observers.
RESULTS: Rotation measured by the RAM averaged 66.9° ± 7 for the right and 67.2° ± 5.8 for the left wrists. Using the STTM there was a mean rotation of 68.6° ± 6.6 for the right and 68.6° ± 6.8 for the left wrists. The overall results showed a significant variability of the measured values between different specimens (P < 0.05). There was no significant difference between left and right wrists of the same specimen, neither for the RAM (P = 0.268) nor for the STTM (P = 0.774). Repeatability coefficients between the observers were low, indicating good repeatability.
CONCLUSIONS: The presented methods are practical tools to quantify intraosseous rotation between distal and proximal scaphoid poles using common volume rendering software. For clinical application the opposite side provides the best reference values to assess malrotation in scaphoid fracture cases. KEY POINTS: Scaphoid intraosseous rotation can be measured using common volume rendering software. The opposite uninjured side provides good reference values for rotation measurement. Assessment of malrotation may impact anatomical reconstruction of scaphoid fractures.

Entities:  

Mesh:

Year:  2014        PMID: 24599621     DOI: 10.1007/s00330-014-3116-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  [Scaphoid fractures--diagnosis, classification and therapy].

Authors:  H Krimmer; R Schmitt; T Herbert
Journal:  Unfallchirurg       Date:  2000-10       Impact factor: 1.000

Review 2.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

3.  Anthropometry of the human scaphoid.

Authors:  Andrew D Heinzelmann; Graeme Archer; Randy R Bindra
Journal:  J Hand Surg Am       Date:  2007-09       Impact factor: 2.230

4.  Scaphoid nonunion and distal fragment resection: analysis with three-dimensional rigid body spring model.

Authors:  Hiroshi Matsuki; Emiko Horii; Masataka Majima; Eiichi Genda; Shukuki Koh; Hitoshi Hirata
Journal:  J Orthop Sci       Date:  2009-04-01       Impact factor: 1.601

5.  Measurement of the scaphoid humpback deformity using longitudinal computed tomography: intra- and interobserver variability using various measurement techniques.

Authors:  G I Bain; J D Bennett; J C MacDermid; G P Slethaug; R S Richards; J H Roth
Journal:  J Hand Surg Am       Date:  1998-01       Impact factor: 2.230

6.  Validity of conventional radiography in determining scaphoid waist fracture displacement.

Authors:  Stephanie A Bernard; Peter M Murray; Michael G Heckman
Journal:  J Orthop Trauma       Date:  2010-07       Impact factor: 2.512

7.  Anatomic features of the carpal scaphoid: validation of biometric measurements and symmetry with three-dimensional MR imaging.

Authors:  D K Smith
Journal:  Radiology       Date:  1993-04       Impact factor: 11.105

8.  Displaced scaphoid waist fractures: the use of a week 4 CT scan to predict the likelihood of union with nonoperative treatment.

Authors:  R Amirfeyz; A Bebbington; N D Downing; J A Oni; T R C Davis
Journal:  J Hand Surg Eur Vol       Date:  2011-04-05

Review 9.  Incidence, mechanism, and natural history of scaphoid fractures.

Authors:  S H Kozin
Journal:  Hand Clin       Date:  2001-11       Impact factor: 1.907

10.  Analysis of scaphoid fracture displacement by three-dimensional computed tomography.

Authors:  R Nakamura; T Imaeda; E Horii; T Miura; N Hayakawa
Journal:  J Hand Surg Am       Date:  1991-05       Impact factor: 2.230

View more
  5 in total

Review 1.  [Anatomy and biomechanics of the scaphoid].

Authors:  M F Langer; S Oeckenpöhler; S Breiter; D Wähnert; B Wieskötter
Journal:  Orthopade       Date:  2016-11       Impact factor: 1.087

2.  3D computational anatomy of the scaphoid and its waist for use in fracture treatment.

Authors:  Marc-Daniel Ahrend; Teun Teunis; Hansrudi Noser; Florian Schmidutz; Geoff Richards; Boyko Gueorguiev; Lukas Kamer
Journal:  J Orthop Surg Res       Date:  2021-03-24       Impact factor: 2.359

3.  Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones.

Authors:  Dominik Gruszka; Robert Herr; Hans Hely; Peer Hofmann; Daniela Klitscher; Alexander Hofmann; Pol Maria Rommens
Journal:  PLoS One       Date:  2016-01-07       Impact factor: 3.240

Review 4.  Cinematic rendering - an alternative to volume rendering for 3D computed tomography imaging.

Authors:  Evelyn Dappa; Kai Higashigaito; Jürgen Fornaro; Sebastian Leschka; Simon Wildermuth; Hatem Alkadhi
Journal:  Insights Imaging       Date:  2016-09-15

5.  Time-dependent changes in bone healing capacity of scaphoid fractures and non-unions.

Authors:  Gernot Schmidle; Hannes Leonhard Ebner; Günter Klima; Kristian Pfaller; Josef Fritz; Romed Hoermann; Markus Gabl
Journal:  J Anat       Date:  2018-02-27       Impact factor: 2.610

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.