Literature DB >> 20577078

Validity of conventional radiography in determining scaphoid waist fracture displacement.

Stephanie A Bernard1, Peter M Murray, Michael G Heckman.   

Abstract

OBJECTIVE: This study examines interpreter accuracy and interobserver agreement in evaluating conventional radiographs for scaphoid waist fracture displacement.
METHODS: Six fresh-frozen cadaver arms were obtained transected above the elbow. A waist fracture was created in each scaphoid. In a random fashion, three of the fractures were displaced 1 mm in the radial-ulnar plane, whereas the other three were reapproximated to anatomic position before all fractures were stabilized with radiolucent adhesive glue. A three-view conventional radiography series consisting of a posterior-anterior, lateral, and ulnar-deviated elongated scaphoid view was obtained for each wrist. Each radiograph was then presented in the same sequence for interpretation to six independent observers: two hand surgeons, two musculoskeletal radiologists, and two senior orthopaedic surgery residents who were all blinded to the actual fracture pattern.
RESULTS: In 14 of the 18 (78%) displaced fracture radiographic series, the interpreters correctly recognized displacement being present. However, displacement was also reported in six of the 18 (33%) nondisplaced fracture series. The estimated overall accuracy of all readings for distinguishing between displaced and nondisplaced fractures was 72%. Of the 90 total possible pairwise agreements between interpreters regarding fracture displacement, there were 54 actual agreements (60%), and kappa was estimated to be 0.31. Taken together, these two measures of agreement can be interpreted as indicating poor to moderate agreement.
CONCLUSION: Our results suggest that conventional radiography is not reliable in determining 1-mm scaphoid waist fracture displacement in the radioulnar plane and also indicated a lack of strong interobserver agreement.

Entities:  

Mesh:

Year:  2010        PMID: 20577078     DOI: 10.1097/BOT.0b013e3181c3e865

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  8 in total

1.  Training improves interobserver reliability for the diagnosis of scaphoid fracture displacement.

Authors:  Geert A Buijze; Thierry G Guitton; C Niek van Dijk; David Ring
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Interobserver Variability of the Diagnosis of Scaphoid Proximal Pole Fractures.

Authors:  Reinier B Beks; Tessa Drijkoningen; Femke Claessen; Thierry G Guitton; David Ring
Journal:  J Wrist Surg       Date:  2018-04-10

3.  Importance of Computed Tomography in Determining Displacement in Scaphoid Fractures.

Authors:  Emily Gilley; Sameer K Puri; Krystle A Hearns; Andrew J Weiland; Michelle G Carlson
Journal:  J Wrist Surg       Date:  2017-07-06

4.  Intraosseous rotation of the scaphoid: assessment by using a 3D CT model--an anatomic study.

Authors:  Gernot Schmidle; Michael Rieger; Andrea Sabine Klauser; Michael Thauerer; Romed Hoermann; Markus Gabl
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

5.  Radiographic Parameters to Predict Union After Volar Percutaneous Fixation of Herbert Type B1 and B2 Scaphoid Fractures.

Authors:  Mostafa Mahmoud; Mohamed Hegazy; Sherif Ahmed Khaled; Nasef Mohamed Nasef Abdelatif; Walid Osman; John C Elfar
Journal:  J Hand Surg Am       Date:  2016-02       Impact factor: 2.230

Review 6.  The use of cone-beam computed tomography (CBCT) in radiocarpal fractures: a diagnostic test accuracy meta-analysis.

Authors:  Emma Fitzpatrick; Vivek Sharma; Djamila Rojoa; Firas Raheman; Harvinder Singh
Journal:  Skeletal Radiol       Date:  2021-09-20       Impact factor: 2.199

7.  Correlation of CT imaging and histology to guide bone graft selection in scaphoid non-union surgery.

Authors:  Gernot Schmidle; Hannes Leonhard Ebner; Andrea Sabine Klauser; Josef Fritz; Rohit Arora; Markus Gabl
Journal:  Arch Orthop Trauma Surg       Date:  2018-07-13       Impact factor: 3.067

8.  Conservatively Managed, Displaced Scaphoid Fracture in a Young, Female Collegiate Basketball Player.

Authors:  Samantha Braun; Ashley Yelinek
Journal:  Cureus       Date:  2020-08-16
  8 in total