Literature DB >> 8451410

Anatomic features of the carpal scaphoid: validation of biometric measurements and symmetry with three-dimensional MR imaging.

D K Smith1.   

Abstract

The goals of reconstructive surgery for scaphoid fracture nonunions include restoration of normal scaphoid length and shape by use of the contralateral scaphoid bone as a geometric model. A literature search revealed limited documentation of normal biometric measurements and no validation of scaphoid anatomic symmetry. A study was performed to provide normative data and evaluate the right-to-left symmetry of specific geometric measurements of the scaphoid. One hundred normal carpal scaphoid bones in 30 healthy subjects and 40 patients were examined with three-dimensional magnetic resonance (MR) imaging. Standardized oblique projections were reconstructed from each three-dimensional data set, and seven biometric measurements of each scaphoid were obtained. Normative data from the study group were obtained by means of analysis of all 100 scaphoids. Right-to-left symmetry was validated with the biometric measurements of both scaphoids in the healthy subjects. These data validate scaphoid symmetry and provide 95% confidence intervals for specific biometric measurements that are used for preoperative planning of surgical reconstruction of scaphoid nonunions.

Entities:  

Mesh:

Year:  1993        PMID: 8451410     DOI: 10.1148/radiology.187.1.8451410

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Study of carpal bone morphology and position in three dimensions by image analysis from computed tomography scans of the wrist.

Authors:  F Canovas; Y Roussanne; G Captier; F Bonnel
Journal:  Surg Radiol Anat       Date:  2004-05-07       Impact factor: 1.246

2.  Determination of the Central Axis of the Scaphoid.

Authors:  Dennis J Heaton; Thomas Trumble; Diana Rhodes
Journal:  J Wrist Surg       Date:  2015-08

3.  Intraosseous rotation of the scaphoid: assessment by using a 3D CT model--an anatomic study.

Authors:  Gernot Schmidle; Michael Rieger; Andrea Sabine Klauser; Michael Thauerer; Romed Hoermann; Markus Gabl
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

4.  Quantification of contralateral differences of the scaphoid: a comparison of bone geometry in three dimensions.

Authors:  Claudio Letta; Andreas Schweizer; Philipp Fürnstahl
Journal:  Anat Res Int       Date:  2014-02-11

5.  Three-Dimensional Assessment of Bilateral Symmetry of the Scaphoid: An Anatomic Study.

Authors:  Paul W L ten Berg; Johannes G G Dobbe; Simon D Strackee; Geert J Streekstra
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.